Cargando…
Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy
Broadband, high-resolution, heterodyne, mid-infrared absorption spectroscopy was performed with a high-speed quantum cascade (QC) detector. By strictly reducing the device capacitance and inductance via air-bridge wiring and a small mesa structure, a 3-dB frequency response over 20 GHz was obtained...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433808/ https://www.ncbi.nlm.nih.gov/pubmed/34502596 http://dx.doi.org/10.3390/s21175706 |
_version_ | 1783751446934585344 |
---|---|
author | Dougakiuchi, Tatsuo Akikusa, Naota |
author_facet | Dougakiuchi, Tatsuo Akikusa, Naota |
author_sort | Dougakiuchi, Tatsuo |
collection | PubMed |
description | Broadband, high-resolution, heterodyne, mid-infrared absorption spectroscopy was performed with a high-speed quantum cascade (QC) detector. By strictly reducing the device capacitance and inductance via air-bridge wiring and a small mesa structure, a 3-dB frequency response over 20 GHz was obtained for the QC detector, which had a 4.6-μm peak wavelength response. In addition to the high-speed, it exhibited low noise characteristics limited only by Johnson–Nyquist noise, bias-free operation without cooling, and photoresponse linearity over a wide dynamic range. In the detector characterization, the noise-equivalent power was 7.7 × 10(−11) W/Hz(1/2) at 4.6 μm, and it had good photoresponse linearity up to 250 mW, with respect to the input light power. Broadband and high-accuracy molecular spectroscopy based on heterodyne detection was demonstrated by means of two distributed-feedback 4.5-μm QC lasers. Specifically, several nitrous oxide absorption lines were acquired over a wavelength range of 0.8 cm(−1) with the wide-band QC detector. |
format | Online Article Text |
id | pubmed-8433808 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84338082021-09-12 Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy Dougakiuchi, Tatsuo Akikusa, Naota Sensors (Basel) Article Broadband, high-resolution, heterodyne, mid-infrared absorption spectroscopy was performed with a high-speed quantum cascade (QC) detector. By strictly reducing the device capacitance and inductance via air-bridge wiring and a small mesa structure, a 3-dB frequency response over 20 GHz was obtained for the QC detector, which had a 4.6-μm peak wavelength response. In addition to the high-speed, it exhibited low noise characteristics limited only by Johnson–Nyquist noise, bias-free operation without cooling, and photoresponse linearity over a wide dynamic range. In the detector characterization, the noise-equivalent power was 7.7 × 10(−11) W/Hz(1/2) at 4.6 μm, and it had good photoresponse linearity up to 250 mW, with respect to the input light power. Broadband and high-accuracy molecular spectroscopy based on heterodyne detection was demonstrated by means of two distributed-feedback 4.5-μm QC lasers. Specifically, several nitrous oxide absorption lines were acquired over a wavelength range of 0.8 cm(−1) with the wide-band QC detector. MDPI 2021-08-24 /pmc/articles/PMC8433808/ /pubmed/34502596 http://dx.doi.org/10.3390/s21175706 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Dougakiuchi, Tatsuo Akikusa, Naota Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy |
title | Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy |
title_full | Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy |
title_fullStr | Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy |
title_full_unstemmed | Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy |
title_short | Application of High-Speed Quantum Cascade Detectors for Mid-Infrared, Broadband, High-Resolution Spectroscopy |
title_sort | application of high-speed quantum cascade detectors for mid-infrared, broadband, high-resolution spectroscopy |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8433808/ https://www.ncbi.nlm.nih.gov/pubmed/34502596 http://dx.doi.org/10.3390/s21175706 |
work_keys_str_mv | AT dougakiuchitatsuo applicationofhighspeedquantumcascadedetectorsformidinfraredbroadbandhighresolutionspectroscopy AT akikusanaota applicationofhighspeedquantumcascadedetectorsformidinfraredbroadbandhighresolutionspectroscopy |