Cargando…
3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis
The aim of the paper is to design, manufacture, and test an off-axis composite profile of circular cross-section. Composite profile based on continuous carbon fibers reinforcing the onyx matrix, i.e., a matrix that consists of nylon and micro carbon fibers, was produced by fused deposition modeling...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434518/ https://www.ncbi.nlm.nih.gov/pubmed/34502990 http://dx.doi.org/10.3390/polym13172949 |
_version_ | 1783751618881126400 |
---|---|
author | Kalova, Martina Rusnakova, Sona Krzikalla, David Mesicek, Jakub Tomasek, Radek Podeprelova, Adela Rosicky, Jiri Pagac, Marek |
author_facet | Kalova, Martina Rusnakova, Sona Krzikalla, David Mesicek, Jakub Tomasek, Radek Podeprelova, Adela Rosicky, Jiri Pagac, Marek |
author_sort | Kalova, Martina |
collection | PubMed |
description | The aim of the paper is to design, manufacture, and test an off-axis composite profile of circular cross-section. Composite profile based on continuous carbon fibers reinforcing the onyx matrix, i.e., a matrix that consists of nylon and micro carbon fibers, was produced by fused deposition modeling (FDM) method. A buckling test of the six printed composite specimens was performed on a tensile test machine. The values of the experiment were compared with the values of the computational simulation using the Finite Element Method (FEM) analysis. The mean value of the experimentally determined critical force at which the composite profile failed was 3102 N, while the value of the critical force by FEM analysis was calculated to be 2879 N. Thus, reliability of the simulation to determine the critical force differed from the experimental procedure by only 7%. FEM analysis revealed that the primary failure of 3D printed composite parts was not due to loss of stability, but due to material failure. With great accuracy, the results of the comparison show that it is possible to predict the mechanical properties of 3D printed composite laminates on the basis of a theoretical model. |
format | Online Article Text |
id | pubmed-8434518 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84345182021-09-12 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis Kalova, Martina Rusnakova, Sona Krzikalla, David Mesicek, Jakub Tomasek, Radek Podeprelova, Adela Rosicky, Jiri Pagac, Marek Polymers (Basel) Article The aim of the paper is to design, manufacture, and test an off-axis composite profile of circular cross-section. Composite profile based on continuous carbon fibers reinforcing the onyx matrix, i.e., a matrix that consists of nylon and micro carbon fibers, was produced by fused deposition modeling (FDM) method. A buckling test of the six printed composite specimens was performed on a tensile test machine. The values of the experiment were compared with the values of the computational simulation using the Finite Element Method (FEM) analysis. The mean value of the experimentally determined critical force at which the composite profile failed was 3102 N, while the value of the critical force by FEM analysis was calculated to be 2879 N. Thus, reliability of the simulation to determine the critical force differed from the experimental procedure by only 7%. FEM analysis revealed that the primary failure of 3D printed composite parts was not due to loss of stability, but due to material failure. With great accuracy, the results of the comparison show that it is possible to predict the mechanical properties of 3D printed composite laminates on the basis of a theoretical model. MDPI 2021-08-31 /pmc/articles/PMC8434518/ /pubmed/34502990 http://dx.doi.org/10.3390/polym13172949 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Kalova, Martina Rusnakova, Sona Krzikalla, David Mesicek, Jakub Tomasek, Radek Podeprelova, Adela Rosicky, Jiri Pagac, Marek 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis |
title | 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis |
title_full | 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis |
title_fullStr | 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis |
title_full_unstemmed | 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis |
title_short | 3D Printed Hollow Off-Axis Profiles Based on Carbon Fiber-Reinforced Polymers: Mechanical Testing and Finite Element Method Analysis |
title_sort | 3d printed hollow off-axis profiles based on carbon fiber-reinforced polymers: mechanical testing and finite element method analysis |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434518/ https://www.ncbi.nlm.nih.gov/pubmed/34502990 http://dx.doi.org/10.3390/polym13172949 |
work_keys_str_mv | AT kalovamartina 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT rusnakovasona 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT krzikalladavid 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT mesicekjakub 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT tomasekradek 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT podeprelovaadela 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT rosickyjiri 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis AT pagacmarek 3dprintedhollowoffaxisprofilesbasedoncarbonfiberreinforcedpolymersmechanicaltestingandfiniteelementmethodanalysis |