Cargando…

An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations

In this paper, we describe a low-cost microwave microfluidic system of ultrahigh sensitivity for detecting small changes in the concentration of polar solutions (liquid dielectrics) in the 2.4 GHz ISM band. Its principle of operation is based on microwave interferometry, which is implemented using p...

Descripción completa

Detalles Bibliográficos
Autores principales: Słobodzian, Piotr, Szostak, Krzysztof, Skowronek, Katarzyna, Jasińska, Laura, Malecha, Karol
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434589/
https://www.ncbi.nlm.nih.gov/pubmed/34502707
http://dx.doi.org/10.3390/s21175816
_version_ 1783751635751665664
author Słobodzian, Piotr
Szostak, Krzysztof
Skowronek, Katarzyna
Jasińska, Laura
Malecha, Karol
author_facet Słobodzian, Piotr
Szostak, Krzysztof
Skowronek, Katarzyna
Jasińska, Laura
Malecha, Karol
author_sort Słobodzian, Piotr
collection PubMed
description In this paper, we describe a low-cost microwave microfluidic system of ultrahigh sensitivity for detecting small changes in the concentration of polar solutions (liquid dielectrics) in the 2.4 GHz ISM band. Its principle of operation is based on microwave interferometry, which is implemented using planar microstrip lines and integrated microwave components. The key features of this system include small solution intake (<200 µL per measurement), short time of measurement (ca. 20 ms), ultrahigh sensitivity of concentration changes (up to 55 dB/%), and low error of measurement (below 0.1%). The ultrahigh sensitivity was proven experimentally by measurements of the fat content of milk. In addition, it is a user-friendly system due to an effortless and fast calibration procedure. Moreover, it can be made relatively compact (<20 cm(2)) and features low power consumption (200 mW). Thus, the proposed system is perfect for industrial applications, especially for highly integrated lab-on-chip devices.
format Online
Article
Text
id pubmed-8434589
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84345892021-09-12 An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations Słobodzian, Piotr Szostak, Krzysztof Skowronek, Katarzyna Jasińska, Laura Malecha, Karol Sensors (Basel) Article In this paper, we describe a low-cost microwave microfluidic system of ultrahigh sensitivity for detecting small changes in the concentration of polar solutions (liquid dielectrics) in the 2.4 GHz ISM band. Its principle of operation is based on microwave interferometry, which is implemented using planar microstrip lines and integrated microwave components. The key features of this system include small solution intake (<200 µL per measurement), short time of measurement (ca. 20 ms), ultrahigh sensitivity of concentration changes (up to 55 dB/%), and low error of measurement (below 0.1%). The ultrahigh sensitivity was proven experimentally by measurements of the fat content of milk. In addition, it is a user-friendly system due to an effortless and fast calibration procedure. Moreover, it can be made relatively compact (<20 cm(2)) and features low power consumption (200 mW). Thus, the proposed system is perfect for industrial applications, especially for highly integrated lab-on-chip devices. MDPI 2021-08-29 /pmc/articles/PMC8434589/ /pubmed/34502707 http://dx.doi.org/10.3390/s21175816 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Słobodzian, Piotr
Szostak, Krzysztof
Skowronek, Katarzyna
Jasińska, Laura
Malecha, Karol
An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations
title An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations
title_full An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations
title_fullStr An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations
title_full_unstemmed An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations
title_short An Ultrahigh Sensitive Microwave Microfluidic System for Fast and Continuous Measurements of Liquid Solution Concentrations
title_sort ultrahigh sensitive microwave microfluidic system for fast and continuous measurements of liquid solution concentrations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434589/
https://www.ncbi.nlm.nih.gov/pubmed/34502707
http://dx.doi.org/10.3390/s21175816
work_keys_str_mv AT słobodzianpiotr anultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT szostakkrzysztof anultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT skowronekkatarzyna anultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT jasinskalaura anultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT malechakarol anultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT słobodzianpiotr ultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT szostakkrzysztof ultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT skowronekkatarzyna ultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT jasinskalaura ultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations
AT malechakarol ultrahighsensitivemicrowavemicrofluidicsystemforfastandcontinuousmeasurementsofliquidsolutionconcentrations