Cargando…

Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition

In order to calibrate the magnetic measurement system used in guided munition on site, a two-stage calibration (TSC) scheme without reference is proposed in this paper. Analyzing the interfering magnetic field in the projectile and misalignment angles between the projectile coordinate system and mea...

Descripción completa

Detalles Bibliográficos
Autores principales: Xue, Yuyang, Zhang, Xiaoming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434620/
https://www.ncbi.nlm.nih.gov/pubmed/34502690
http://dx.doi.org/10.3390/s21175799
_version_ 1783751643114766336
author Xue, Yuyang
Zhang, Xiaoming
author_facet Xue, Yuyang
Zhang, Xiaoming
author_sort Xue, Yuyang
collection PubMed
description In order to calibrate the magnetic measurement system used in guided munition on site, a two-stage calibration (TSC) scheme without reference is proposed in this paper. Analyzing the interfering magnetic field in the projectile and misalignment angles between the projectile coordinate system and measurement coordinate system establishes a proper mathematical equivalent model and derives a calibration method. The first stage is ellipsoid fitting to obtain the equivalent zero-offset, equivalent sensitivity and equivalent non-orthogonal angles of the sensor; the second stage is to calibrate the misalignment angles between the projectile coordinate system and the measurement coordinate system with the three-position calibration (TPC) method. Complete calibration is convenient to operate and does not need an additional reference, which has wide applicability. The simulation results show that the deviation in the measured value after compensation is within 100 nT. The experiment proves that the error of compensated magnetic value is about 150 nT, which meets the accuracy of requirements in guided munitions.
format Online
Article
Text
id pubmed-8434620
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84346202021-09-12 Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition Xue, Yuyang Zhang, Xiaoming Sensors (Basel) Article In order to calibrate the magnetic measurement system used in guided munition on site, a two-stage calibration (TSC) scheme without reference is proposed in this paper. Analyzing the interfering magnetic field in the projectile and misalignment angles between the projectile coordinate system and measurement coordinate system establishes a proper mathematical equivalent model and derives a calibration method. The first stage is ellipsoid fitting to obtain the equivalent zero-offset, equivalent sensitivity and equivalent non-orthogonal angles of the sensor; the second stage is to calibrate the misalignment angles between the projectile coordinate system and the measurement coordinate system with the three-position calibration (TPC) method. Complete calibration is convenient to operate and does not need an additional reference, which has wide applicability. The simulation results show that the deviation in the measured value after compensation is within 100 nT. The experiment proves that the error of compensated magnetic value is about 150 nT, which meets the accuracy of requirements in guided munitions. MDPI 2021-08-28 /pmc/articles/PMC8434620/ /pubmed/34502690 http://dx.doi.org/10.3390/s21175799 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Xue, Yuyang
Zhang, Xiaoming
Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition
title Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition
title_full Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition
title_fullStr Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition
title_full_unstemmed Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition
title_short Two-Stage Calibration Scheme for Magnetic Measurement System on Guided Munition
title_sort two-stage calibration scheme for magnetic measurement system on guided munition
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8434620/
https://www.ncbi.nlm.nih.gov/pubmed/34502690
http://dx.doi.org/10.3390/s21175799
work_keys_str_mv AT xueyuyang twostagecalibrationschemeformagneticmeasurementsystemonguidedmunition
AT zhangxiaoming twostagecalibrationschemeformagneticmeasurementsystemonguidedmunition