Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing

- 20-year-old male road-traffic accident - Sustained right acetabulum fracture, left proximal femur fracture, right patella fracture and pulmonary contusions - Had fixation within 4 days of his left proximal femur fracture and his right acetabulum: -. Following fixation of his left femur fracture, d...

Descripción completa

Detalles Bibliográficos
Autores principales: Chloros, George D., Giannoudis, Vasileios P., Giannoudis, Peter V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8436075/
https://www.ncbi.nlm.nih.gov/pubmed/34541277
http://dx.doi.org/10.1016/j.tcr.2021.100532
_version_ 1783751930815709184
author Chloros, George D.
Giannoudis, Vasileios P.
Giannoudis, Peter V.
author_facet Chloros, George D.
Giannoudis, Vasileios P.
Giannoudis, Peter V.
author_sort Chloros, George D.
collection PubMed
description - 20-year-old male road-traffic accident - Sustained right acetabulum fracture, left proximal femur fracture, right patella fracture and pulmonary contusions - Had fixation within 4 days of his left proximal femur fracture and his right acetabulum: -. Following fixation of his left femur fracture, developed symptoms of complete left sciatic nerve palsy. -. At the time of surgery, a heygroves clamp around the neck of the femur was used to assist in the reduction of the fracture. -. Subsequent exploration of the sciatic nerve showed several clamp indentations on it but fascicles in continuity. - Nerve conduction studies at 4 months post-operatively confirmed a high sciatic nerve injury. - The patient has still not recovered any function 1 year post-operatively.
format Online
Article
Text
id pubmed-8436075
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-84360752021-09-17 Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing Chloros, George D. Giannoudis, Vasileios P. Giannoudis, Peter V. Trauma Case Rep Morbidity and Mortality Case Report - 20-year-old male road-traffic accident - Sustained right acetabulum fracture, left proximal femur fracture, right patella fracture and pulmonary contusions - Had fixation within 4 days of his left proximal femur fracture and his right acetabulum: -. Following fixation of his left femur fracture, developed symptoms of complete left sciatic nerve palsy. -. At the time of surgery, a heygroves clamp around the neck of the femur was used to assist in the reduction of the fracture. -. Subsequent exploration of the sciatic nerve showed several clamp indentations on it but fascicles in continuity. - Nerve conduction studies at 4 months post-operatively confirmed a high sciatic nerve injury. - The patient has still not recovered any function 1 year post-operatively. Elsevier 2021-09-06 /pmc/articles/PMC8436075/ /pubmed/34541277 http://dx.doi.org/10.1016/j.tcr.2021.100532 Text en © 2021 The Authors. Published by Elsevier Ltd. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Morbidity and Mortality Case Report
Chloros, George D.
Giannoudis, Vasileios P.
Giannoudis, Peter V.
Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
title Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
title_full Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
title_fullStr Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
title_full_unstemmed Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
title_short Iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
title_sort iatrogenic sciatic nerve injury secondary to clamp placement around the femoral neck during proximal femoral fracture intramedullary nailing
topic Morbidity and Mortality Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8436075/
https://www.ncbi.nlm.nih.gov/pubmed/34541277
http://dx.doi.org/10.1016/j.tcr.2021.100532
work_keys_str_mv AT chlorosgeorged iatrogenicsciaticnerveinjurysecondarytoclampplacementaroundthefemoralneckduringproximalfemoralfractureintramedullarynailing
AT giannoudisvasileiosp iatrogenicsciaticnerveinjurysecondarytoclampplacementaroundthefemoralneckduringproximalfemoralfractureintramedullarynailing
AT giannoudispeterv iatrogenicsciaticnerveinjurysecondarytoclampplacementaroundthefemoralneckduringproximalfemoralfractureintramedullarynailing