Cargando…
Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors
This article analyzes the accuracy of needle track and dose of a 3-dimensional printing template (3DPT) in the treatment of thoracic tumor with radioactive I-125 seed implantation (RISI). A total of 28 patients were included. The technical process included: (i) preoperative CT positioning, (ii) preo...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438469/ https://www.ncbi.nlm.nih.gov/pubmed/34350955 http://dx.doi.org/10.1093/jrr/rrab068 |
_version_ | 1783752358604308480 |
---|---|
author | Ji, Zhe Sun, Haitao Jiang, Yuliang Chen, Yi Guo, Fuxin Fan, Jinghong Wang, Junjie |
author_facet | Ji, Zhe Sun, Haitao Jiang, Yuliang Chen, Yi Guo, Fuxin Fan, Jinghong Wang, Junjie |
author_sort | Ji, Zhe |
collection | PubMed |
description | This article analyzes the accuracy of needle track and dose of a 3-dimensional printing template (3DPT) in the treatment of thoracic tumor with radioactive I-125 seed implantation (RISI). A total of 28 patients were included. The technical process included: (i) preoperative CT positioning, (ii) preoperative planning design, (iii) 3DPT design and printing, (iv) 3DPT alignment, (v) puncture and seed implantation. The errors of needle position and dosimetric parameters were analyzed. A total of 318 needles were used. The mean errors in needle depth, needle insertion point, needle tip and needle angle were 0.52 ± 0.48 cm, 3.4 ± 1.7 mm, 4.4 ± 2.9 mm and 2.8 ± 1.7°, respectively. The differences between actual needle insertion angle and needle depth and those designed in the preoperative were statistically significant (p < 0.05). The mean values of all the errors of the chest wall cases were smaller than those of the lungs, and the differences were statistically significant (p < 0.05). There was no significant difference between the D90 calculated in the postoperative plan and those designed in the preoperative and intraoperative plans (p > 0.05). Some dosimetric parameters of preoperative plans such as V100, V200, CI and HI were not consistent with that of preoperative plans, and the difference was statistically significant (p < 0.05). However, there were no statistical difference in the dosimetric parameters between the postoperative plans and intraoperative plans (p > 0.05). We conclude that for thoracic tumors, even under the guidance of 3DPT, there will be errors. The plan should be optimized in real time during the operation. |
format | Online Article Text |
id | pubmed-8438469 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-84384692021-09-15 Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors Ji, Zhe Sun, Haitao Jiang, Yuliang Chen, Yi Guo, Fuxin Fan, Jinghong Wang, Junjie J Radiat Res Oncology/Medicine This article analyzes the accuracy of needle track and dose of a 3-dimensional printing template (3DPT) in the treatment of thoracic tumor with radioactive I-125 seed implantation (RISI). A total of 28 patients were included. The technical process included: (i) preoperative CT positioning, (ii) preoperative planning design, (iii) 3DPT design and printing, (iv) 3DPT alignment, (v) puncture and seed implantation. The errors of needle position and dosimetric parameters were analyzed. A total of 318 needles were used. The mean errors in needle depth, needle insertion point, needle tip and needle angle were 0.52 ± 0.48 cm, 3.4 ± 1.7 mm, 4.4 ± 2.9 mm and 2.8 ± 1.7°, respectively. The differences between actual needle insertion angle and needle depth and those designed in the preoperative were statistically significant (p < 0.05). The mean values of all the errors of the chest wall cases were smaller than those of the lungs, and the differences were statistically significant (p < 0.05). There was no significant difference between the D90 calculated in the postoperative plan and those designed in the preoperative and intraoperative plans (p > 0.05). Some dosimetric parameters of preoperative plans such as V100, V200, CI and HI were not consistent with that of preoperative plans, and the difference was statistically significant (p < 0.05). However, there were no statistical difference in the dosimetric parameters between the postoperative plans and intraoperative plans (p > 0.05). We conclude that for thoracic tumors, even under the guidance of 3DPT, there will be errors. The plan should be optimized in real time during the operation. Oxford University Press 2021-08-05 /pmc/articles/PMC8438469/ /pubmed/34350955 http://dx.doi.org/10.1093/jrr/rrab068 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com |
spellingShingle | Oncology/Medicine Ji, Zhe Sun, Haitao Jiang, Yuliang Chen, Yi Guo, Fuxin Fan, Jinghong Wang, Junjie Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors |
title | Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors |
title_full | Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors |
title_fullStr | Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors |
title_full_unstemmed | Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors |
title_short | Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors |
title_sort | analysis on the accuracy of ct-guided radioactive i-125 seed implantation with 3d printing template assistance in the treatment of thoracic malignant tumors |
topic | Oncology/Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438469/ https://www.ncbi.nlm.nih.gov/pubmed/34350955 http://dx.doi.org/10.1093/jrr/rrab068 |
work_keys_str_mv | AT jizhe analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors AT sunhaitao analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors AT jiangyuliang analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors AT chenyi analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors AT guofuxin analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors AT fanjinghong analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors AT wangjunjie analysisontheaccuracyofctguidedradioactivei125seedimplantationwith3dprintingtemplateassistanceinthetreatmentofthoracicmalignanttumors |