Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation

The question of preserving the patent ductus arteriosus (PDA) during the modified Blalock–Taussig shunt (MBTS) procedure remains controversial. The goal of this study was to investigate the effects of the PDA on the flow features of the MBTS to help with preoperative surgery design and postoperative...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiong, Jiwen, Sun, Qi, Qian, Yi, Hu, Liwei, Tong, Zhirong, Liu, Jinfen, Liu, Jinlong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438520/
https://www.ncbi.nlm.nih.gov/pubmed/34531758
http://dx.doi.org/10.3389/fphys.2021.707128
_version_ 1783752363058659328
author Xiong, Jiwen
Sun, Qi
Qian, Yi
Hu, Liwei
Tong, Zhirong
Liu, Jinfen
Liu, Jinlong
author_facet Xiong, Jiwen
Sun, Qi
Qian, Yi
Hu, Liwei
Tong, Zhirong
Liu, Jinfen
Liu, Jinlong
author_sort Xiong, Jiwen
collection PubMed
description The question of preserving the patent ductus arteriosus (PDA) during the modified Blalock–Taussig shunt (MBTS) procedure remains controversial. The goal of this study was to investigate the effects of the PDA on the flow features of the MBTS to help with preoperative surgery design and postoperative prediction. In this study, a patient with pulmonary atresia and PDA was included. A patient-specific three-dimensional model was reconstructed, and virtual surgeries of shunt insertion and ductus ligation were performed using computer-aided design. Computational fluid dynamics was utilized to analyze the hemodynamic parameters of varied models based on the patient-specific anatomy and physiological data. The preservation of the PDA competitively reduced the shunt flow but increased total pulmonary perfusion. The shunt flow and ductal flow collided, causing significant and complicated turbulence in the pulmonary artery where low wall shear stress, high oscillatory shear index, and high relative residence time were distributed. The highest energy loss was found when the PDA was preserved. The preservation of PDA is not recommended during MBTS procedures because it negatively influences hemodynamics. This may lead to pulmonary overperfusion, inadequate systemic perfusion, and a heavier cardiac burden, thus increasing the risk of heart failure. Also, it seems to bring no benefit in terms of reducing the risk for thrombosis.
format Online
Article
Text
id pubmed-8438520
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-84385202021-09-15 Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation Xiong, Jiwen Sun, Qi Qian, Yi Hu, Liwei Tong, Zhirong Liu, Jinfen Liu, Jinlong Front Physiol Physiology The question of preserving the patent ductus arteriosus (PDA) during the modified Blalock–Taussig shunt (MBTS) procedure remains controversial. The goal of this study was to investigate the effects of the PDA on the flow features of the MBTS to help with preoperative surgery design and postoperative prediction. In this study, a patient with pulmonary atresia and PDA was included. A patient-specific three-dimensional model was reconstructed, and virtual surgeries of shunt insertion and ductus ligation were performed using computer-aided design. Computational fluid dynamics was utilized to analyze the hemodynamic parameters of varied models based on the patient-specific anatomy and physiological data. The preservation of the PDA competitively reduced the shunt flow but increased total pulmonary perfusion. The shunt flow and ductal flow collided, causing significant and complicated turbulence in the pulmonary artery where low wall shear stress, high oscillatory shear index, and high relative residence time were distributed. The highest energy loss was found when the PDA was preserved. The preservation of PDA is not recommended during MBTS procedures because it negatively influences hemodynamics. This may lead to pulmonary overperfusion, inadequate systemic perfusion, and a heavier cardiac burden, thus increasing the risk of heart failure. Also, it seems to bring no benefit in terms of reducing the risk for thrombosis. Frontiers Media S.A. 2021-08-31 /pmc/articles/PMC8438520/ /pubmed/34531758 http://dx.doi.org/10.3389/fphys.2021.707128 Text en Copyright © 2021 Xiong, Sun, Qian, Hu, Tong, Liu and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Xiong, Jiwen
Sun, Qi
Qian, Yi
Hu, Liwei
Tong, Zhirong
Liu, Jinfen
Liu, Jinlong
Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation
title Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation
title_full Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation
title_fullStr Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation
title_full_unstemmed Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation
title_short Effects of Patent Ductus Arteriosus on the Hemodynamics of Modified Blalock–Taussig Shunt Based on Patient-Specific Simulation
title_sort effects of patent ductus arteriosus on the hemodynamics of modified blalock–taussig shunt based on patient-specific simulation
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438520/
https://www.ncbi.nlm.nih.gov/pubmed/34531758
http://dx.doi.org/10.3389/fphys.2021.707128
work_keys_str_mv AT xiongjiwen effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation
AT sunqi effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation
AT qianyi effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation
AT huliwei effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation
AT tongzhirong effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation
AT liujinfen effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation
AT liujinlong effectsofpatentductusarteriosusonthehemodynamicsofmodifiedblalocktaussigshuntbasedonpatientspecificsimulation