Cargando…

Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study

OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study wa...

Descripción completa

Detalles Bibliográficos
Autores principales: van Rens, Matheus F P T, Hugill, Kevin, Mahmah, Mohamad A, Bayoumi, Mohammad, Francia, Airene L V, Garcia, Krisha L P, van Loon, F H J
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438911/
https://www.ncbi.nlm.nih.gov/pubmed/34497079
http://dx.doi.org/10.1136/bmjopen-2020-047788
_version_ 1783752435917914112
author van Rens, Matheus F P T
Hugill, Kevin
Mahmah, Mohamad A
Bayoumi, Mohammad
Francia, Airene L V
Garcia, Krisha L P
van Loon, F H J
author_facet van Rens, Matheus F P T
Hugill, Kevin
Mahmah, Mohamad A
Bayoumi, Mohammad
Francia, Airene L V
Garcia, Krisha L P
van Loon, F H J
author_sort van Rens, Matheus F P T
collection PubMed
description OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study was to assess the incidence and evaluate the interactions of risk factors on the occurrence of peripheral intravenous complications in a neonatal population. DESIGN: This was a retrospective observational study. SETTING: The study was performed on the neonatal intensive care unit of the Women’s Wellness and Research Center, Hamad Medical Corporation, Qatar, as a single-site study. PARTICIPANTS: This study included 12 978 neonates who required intravenous therapy. OUTCOME MEASUREMENTS: The main outcome was the occurrence of any peripheral intravenous cannulation failure, leading to unplanned removal of the device before completion of the intended intravenous therapy. RESULTS: A mean dwell time of 36±28 hours was recorded in participants with no complications, whereas the mean dwell time was 31±23 hours in participants with an indication for premature removal of the peripheral intravenous catheter (PIVC) (p<0.001, t=11.35). Unplanned removal occurred in 59% of cases; the overall complication rate was 18 per 1000 catheter days. Unmodifiable factors affecting PIVC dwell time include lower birth (HR=0.23, 0.20 to 0.28, p<0.001) and current body weight (HR=1.06, 1.03 to 1.10, p=0.018). Cannulation site (HR=1.23, 1.16 to 1.30, p<0.001), the inserted device (HR=0.89, 0.84 to 0.94, p<0.001) and the indication for intravenous treatment (HR=0.76, 0.73 to 0.79, p<0.001) were modifiable factors. CONCLUSION: Most infants experienced a vascular access-related complication. Given the high complication rate, PIVCs should be used judiciously and thought given prior to their use as to whether alternate means of intravenous access might be more appropriate.
format Online
Article
Text
id pubmed-8438911
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-84389112021-09-24 Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study van Rens, Matheus F P T Hugill, Kevin Mahmah, Mohamad A Bayoumi, Mohammad Francia, Airene L V Garcia, Krisha L P van Loon, F H J BMJ Open Nursing OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study was to assess the incidence and evaluate the interactions of risk factors on the occurrence of peripheral intravenous complications in a neonatal population. DESIGN: This was a retrospective observational study. SETTING: The study was performed on the neonatal intensive care unit of the Women’s Wellness and Research Center, Hamad Medical Corporation, Qatar, as a single-site study. PARTICIPANTS: This study included 12 978 neonates who required intravenous therapy. OUTCOME MEASUREMENTS: The main outcome was the occurrence of any peripheral intravenous cannulation failure, leading to unplanned removal of the device before completion of the intended intravenous therapy. RESULTS: A mean dwell time of 36±28 hours was recorded in participants with no complications, whereas the mean dwell time was 31±23 hours in participants with an indication for premature removal of the peripheral intravenous catheter (PIVC) (p<0.001, t=11.35). Unplanned removal occurred in 59% of cases; the overall complication rate was 18 per 1000 catheter days. Unmodifiable factors affecting PIVC dwell time include lower birth (HR=0.23, 0.20 to 0.28, p<0.001) and current body weight (HR=1.06, 1.03 to 1.10, p=0.018). Cannulation site (HR=1.23, 1.16 to 1.30, p<0.001), the inserted device (HR=0.89, 0.84 to 0.94, p<0.001) and the indication for intravenous treatment (HR=0.76, 0.73 to 0.79, p<0.001) were modifiable factors. CONCLUSION: Most infants experienced a vascular access-related complication. Given the high complication rate, PIVCs should be used judiciously and thought given prior to their use as to whether alternate means of intravenous access might be more appropriate. BMJ Publishing Group 2021-09-08 /pmc/articles/PMC8438911/ /pubmed/34497079 http://dx.doi.org/10.1136/bmjopen-2020-047788 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Nursing
van Rens, Matheus F P T
Hugill, Kevin
Mahmah, Mohamad A
Bayoumi, Mohammad
Francia, Airene L V
Garcia, Krisha L P
van Loon, F H J
Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
title Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
title_full Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
title_fullStr Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
title_full_unstemmed Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
title_short Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
title_sort evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
topic Nursing
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438911/
https://www.ncbi.nlm.nih.gov/pubmed/34497079
http://dx.doi.org/10.1136/bmjopen-2020-047788
work_keys_str_mv AT vanrensmatheusfpt evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy
AT hugillkevin evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy
AT mahmahmohamada evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy
AT bayoumimohammad evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy
AT franciaairenelv evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy
AT garciakrishalp evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy
AT vanloonfhj evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy