Cargando…
Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study
OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study wa...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438911/ https://www.ncbi.nlm.nih.gov/pubmed/34497079 http://dx.doi.org/10.1136/bmjopen-2020-047788 |
_version_ | 1783752435917914112 |
---|---|
author | van Rens, Matheus F P T Hugill, Kevin Mahmah, Mohamad A Bayoumi, Mohammad Francia, Airene L V Garcia, Krisha L P van Loon, F H J |
author_facet | van Rens, Matheus F P T Hugill, Kevin Mahmah, Mohamad A Bayoumi, Mohammad Francia, Airene L V Garcia, Krisha L P van Loon, F H J |
author_sort | van Rens, Matheus F P T |
collection | PubMed |
description | OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study was to assess the incidence and evaluate the interactions of risk factors on the occurrence of peripheral intravenous complications in a neonatal population. DESIGN: This was a retrospective observational study. SETTING: The study was performed on the neonatal intensive care unit of the Women’s Wellness and Research Center, Hamad Medical Corporation, Qatar, as a single-site study. PARTICIPANTS: This study included 12 978 neonates who required intravenous therapy. OUTCOME MEASUREMENTS: The main outcome was the occurrence of any peripheral intravenous cannulation failure, leading to unplanned removal of the device before completion of the intended intravenous therapy. RESULTS: A mean dwell time of 36±28 hours was recorded in participants with no complications, whereas the mean dwell time was 31±23 hours in participants with an indication for premature removal of the peripheral intravenous catheter (PIVC) (p<0.001, t=11.35). Unplanned removal occurred in 59% of cases; the overall complication rate was 18 per 1000 catheter days. Unmodifiable factors affecting PIVC dwell time include lower birth (HR=0.23, 0.20 to 0.28, p<0.001) and current body weight (HR=1.06, 1.03 to 1.10, p=0.018). Cannulation site (HR=1.23, 1.16 to 1.30, p<0.001), the inserted device (HR=0.89, 0.84 to 0.94, p<0.001) and the indication for intravenous treatment (HR=0.76, 0.73 to 0.79, p<0.001) were modifiable factors. CONCLUSION: Most infants experienced a vascular access-related complication. Given the high complication rate, PIVCs should be used judiciously and thought given prior to their use as to whether alternate means of intravenous access might be more appropriate. |
format | Online Article Text |
id | pubmed-8438911 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-84389112021-09-24 Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study van Rens, Matheus F P T Hugill, Kevin Mahmah, Mohamad A Bayoumi, Mohammad Francia, Airene L V Garcia, Krisha L P van Loon, F H J BMJ Open Nursing OBJECTIVES: Infants in neonatal units benefit from dependable peripheral intravenous access. However, peripheral intravenous access exposes infants to high rates of clinically minor and serious complications. Despite this, little is known about the interplay of risk factors. The aim of this study was to assess the incidence and evaluate the interactions of risk factors on the occurrence of peripheral intravenous complications in a neonatal population. DESIGN: This was a retrospective observational study. SETTING: The study was performed on the neonatal intensive care unit of the Women’s Wellness and Research Center, Hamad Medical Corporation, Qatar, as a single-site study. PARTICIPANTS: This study included 12 978 neonates who required intravenous therapy. OUTCOME MEASUREMENTS: The main outcome was the occurrence of any peripheral intravenous cannulation failure, leading to unplanned removal of the device before completion of the intended intravenous therapy. RESULTS: A mean dwell time of 36±28 hours was recorded in participants with no complications, whereas the mean dwell time was 31±23 hours in participants with an indication for premature removal of the peripheral intravenous catheter (PIVC) (p<0.001, t=11.35). Unplanned removal occurred in 59% of cases; the overall complication rate was 18 per 1000 catheter days. Unmodifiable factors affecting PIVC dwell time include lower birth (HR=0.23, 0.20 to 0.28, p<0.001) and current body weight (HR=1.06, 1.03 to 1.10, p=0.018). Cannulation site (HR=1.23, 1.16 to 1.30, p<0.001), the inserted device (HR=0.89, 0.84 to 0.94, p<0.001) and the indication for intravenous treatment (HR=0.76, 0.73 to 0.79, p<0.001) were modifiable factors. CONCLUSION: Most infants experienced a vascular access-related complication. Given the high complication rate, PIVCs should be used judiciously and thought given prior to their use as to whether alternate means of intravenous access might be more appropriate. BMJ Publishing Group 2021-09-08 /pmc/articles/PMC8438911/ /pubmed/34497079 http://dx.doi.org/10.1136/bmjopen-2020-047788 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Nursing van Rens, Matheus F P T Hugill, Kevin Mahmah, Mohamad A Bayoumi, Mohammad Francia, Airene L V Garcia, Krisha L P van Loon, F H J Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
title | Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
title_full | Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
title_fullStr | Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
title_full_unstemmed | Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
title_short | Evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
title_sort | evaluation of unmodifiable and potentially modifiable factors affecting peripheral intravenous device-related complications in neonates: a retrospective observational study |
topic | Nursing |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8438911/ https://www.ncbi.nlm.nih.gov/pubmed/34497079 http://dx.doi.org/10.1136/bmjopen-2020-047788 |
work_keys_str_mv | AT vanrensmatheusfpt evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy AT hugillkevin evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy AT mahmahmohamada evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy AT bayoumimohammad evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy AT franciaairenelv evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy AT garciakrishalp evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy AT vanloonfhj evaluationofunmodifiableandpotentiallymodifiablefactorsaffectingperipheralintravenousdevicerelatedcomplicationsinneonatesaretrospectiveobservationalstudy |