Cargando…

The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients

INTRODUCTION: To prevent infection and thrombosis of central venous catheters (CVCs) in hemodialysis patients, different CVC lock solutions are available. Taurolidine-based solutions and citrate in different concentrations are frequently used, but no definite conclusions with regard to superiority h...

Descripción completa

Detalles Bibliográficos
Autores principales: van Roeden, Sonja, van Oevelen, Mathijs, Abrahams, Alferso C., Dekker, Friedo W., Rotmans, Joris I., Meijvis, Sabine C. A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439004/
https://www.ncbi.nlm.nih.gov/pubmed/34517829
http://dx.doi.org/10.1186/s12882-021-02519-3
_version_ 1783752452629069824
author van Roeden, Sonja
van Oevelen, Mathijs
Abrahams, Alferso C.
Dekker, Friedo W.
Rotmans, Joris I.
Meijvis, Sabine C. A.
author_facet van Roeden, Sonja
van Oevelen, Mathijs
Abrahams, Alferso C.
Dekker, Friedo W.
Rotmans, Joris I.
Meijvis, Sabine C. A.
author_sort van Roeden, Sonja
collection PubMed
description INTRODUCTION: To prevent infection and thrombosis of central venous catheters (CVCs) in hemodialysis patients, different CVC lock solutions are available. Taurolidine-based solutions and citrate in different concentrations are frequently used, but no definite conclusions with regard to superiority have been drawn. METHODS: In this retrospective, observational, multicenter study, we aimed to assess the risk for removal of CVC due to infection or catheter malfunction in hemodialysis patients with CVC access for different lock solutions: taurolidine, high-concentrated citrate (46.7%) and low-concentrated citrate (4 or 30%). A multivariable Cox-regression model was used to calculate hazard ratio’s (HR). RESULTS: We identified 1514 patients (median age 65 years, 59% male). In 96 (6%) taurolidine-based lock solutions were used. In 1418 (94%) citrate-based lock solutions were used (high-concentrated 73%, low-concentrated 20%). Taurolidine-based lock solutions were associated with a significantly lower hazard for removal of CVC due to infection or malfunction combined (HR 0.34, 95% CI 0.19–0.64), and for removal of CVC due to infection or malfunction separately (HR 0.36, 95% CI 0.15–0.88 and HR0.33, 95% CI 0.14–0.79). High-concentrated citrate lock solutions were not associated with a decreased hazard for our outcomes, compared to low-concentrated citrate lock solutions. CONCLUSION: Removal of CVC due to infection or catheter malfunction occurred less often with taurolidine-based lock solutions. We present the largest cohort comparing taurolidine- and citrate-based lock solutions yet. However, due to the retrospective observational nature of this study, conclusions with regard to superiority should be drawn with caution.
format Online
Article
Text
id pubmed-8439004
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-84390042021-09-14 The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients van Roeden, Sonja van Oevelen, Mathijs Abrahams, Alferso C. Dekker, Friedo W. Rotmans, Joris I. Meijvis, Sabine C. A. BMC Nephrol Research INTRODUCTION: To prevent infection and thrombosis of central venous catheters (CVCs) in hemodialysis patients, different CVC lock solutions are available. Taurolidine-based solutions and citrate in different concentrations are frequently used, but no definite conclusions with regard to superiority have been drawn. METHODS: In this retrospective, observational, multicenter study, we aimed to assess the risk for removal of CVC due to infection or catheter malfunction in hemodialysis patients with CVC access for different lock solutions: taurolidine, high-concentrated citrate (46.7%) and low-concentrated citrate (4 or 30%). A multivariable Cox-regression model was used to calculate hazard ratio’s (HR). RESULTS: We identified 1514 patients (median age 65 years, 59% male). In 96 (6%) taurolidine-based lock solutions were used. In 1418 (94%) citrate-based lock solutions were used (high-concentrated 73%, low-concentrated 20%). Taurolidine-based lock solutions were associated with a significantly lower hazard for removal of CVC due to infection or malfunction combined (HR 0.34, 95% CI 0.19–0.64), and for removal of CVC due to infection or malfunction separately (HR 0.36, 95% CI 0.15–0.88 and HR0.33, 95% CI 0.14–0.79). High-concentrated citrate lock solutions were not associated with a decreased hazard for our outcomes, compared to low-concentrated citrate lock solutions. CONCLUSION: Removal of CVC due to infection or catheter malfunction occurred less often with taurolidine-based lock solutions. We present the largest cohort comparing taurolidine- and citrate-based lock solutions yet. However, due to the retrospective observational nature of this study, conclusions with regard to superiority should be drawn with caution. BioMed Central 2021-09-13 /pmc/articles/PMC8439004/ /pubmed/34517829 http://dx.doi.org/10.1186/s12882-021-02519-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
van Roeden, Sonja
van Oevelen, Mathijs
Abrahams, Alferso C.
Dekker, Friedo W.
Rotmans, Joris I.
Meijvis, Sabine C. A.
The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
title The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
title_full The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
title_fullStr The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
title_full_unstemmed The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
title_short The best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
title_sort best solution down the line: an observational study on taurolidine- versus citrate-based lock solutions for central venous catheters in hemodialysis patients
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439004/
https://www.ncbi.nlm.nih.gov/pubmed/34517829
http://dx.doi.org/10.1186/s12882-021-02519-3
work_keys_str_mv AT vanroedensonja thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT vanoevelenmathijs thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT abrahamsalfersoc thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT dekkerfriedow thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT rotmansjorisi thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT meijvissabineca thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT thebestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT vanroedensonja bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT vanoevelenmathijs bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT abrahamsalfersoc bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT dekkerfriedow bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT rotmansjorisi bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT meijvissabineca bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients
AT bestsolutiondownthelineanobservationalstudyontaurolidineversuscitratebasedlocksolutionsforcentralvenouscathetersinhemodialysispatients