Cargando…

Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values

Introduction: In this study, we attempt to determine the diagnostic performance of shear wave elastography of the optic nerve and adjacent fat tissue in patients with optic neuritis. Methods: The study included a patient group consisting of 72 eyes of 36 patients who were diagnosed with unilateral o...

Descripción completa

Detalles Bibliográficos
Autores principales: Aybar, Mustafa Devran, Turna, Onder
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Exeley Inc. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439124/
https://www.ncbi.nlm.nih.gov/pubmed/34540272
http://dx.doi.org/10.15557/JoU.2021.0031
_version_ 1783752476584837120
author Aybar, Mustafa Devran
Turna, Onder
author_facet Aybar, Mustafa Devran
Turna, Onder
author_sort Aybar, Mustafa Devran
collection PubMed
description Introduction: In this study, we attempt to determine the diagnostic performance of shear wave elastography of the optic nerve and adjacent fat tissue in patients with optic neuritis. Methods: The study included a patient group consisting of 72 eyes of 36 patients who were diagnosed with unilateral optic neuritis, and an age-matched control group of 36 eyes of 18 healthy subjects. The patient group consisted of 25 multiple sclerosis patients and 11 recurrent isolated optic neuritis patients. The mean shear wave elastography values of the optic nerves and intraorbital fat tissue adjacent optic nerves were recorded using m/s and kPa as units. ROC curve analysis was performed, and the diagnostic accuracy of shear wave elastography values was determined. Results: The mean shear wave elastography values of the optic nerves with neuritis (2.49 ± 0.41 m/s and 17.56 ± 4.42 kPa) were significantly higher than the values of the contralateral normal optic nerves (1.71 ± 0.32 m/s and 9.02 ± 2.34 kPa) (p = 0.006 and p = 0.004, respectively) in the optic neuritis group. The mean shear wave elastography values of intraorbital fat tissue adjacent optic nerves with neuritis (1.87 ± 0.32 m/s and 9.65 ± 1.12 kPa) were significantly higher than the values of the contralateral normal side (1.47 ± 0.27 m/s and 6.78 ± 1.14 kPa) (p = 0.025 and p = 0.022, respectively) in the optic neuritis group. ROC curve analysis showed a high diagnostic accuracy for determining optic neuritis with shear wave elastography values of the optic nerves (AUC 0.955 [95% CI, 0.933–0.978] in m/s and AUC 0.967 [95% CI, 0.940–0.985] in kPa). Conclusions: Shear wave elastography may be an important alternative diagnostic tool in the diagnosis of optic neuritis.
format Online
Article
Text
id pubmed-8439124
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Exeley Inc.
record_format MEDLINE/PubMed
spelling pubmed-84391242021-09-16 Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values Aybar, Mustafa Devran Turna, Onder J Ultrason Medicine Introduction: In this study, we attempt to determine the diagnostic performance of shear wave elastography of the optic nerve and adjacent fat tissue in patients with optic neuritis. Methods: The study included a patient group consisting of 72 eyes of 36 patients who were diagnosed with unilateral optic neuritis, and an age-matched control group of 36 eyes of 18 healthy subjects. The patient group consisted of 25 multiple sclerosis patients and 11 recurrent isolated optic neuritis patients. The mean shear wave elastography values of the optic nerves and intraorbital fat tissue adjacent optic nerves were recorded using m/s and kPa as units. ROC curve analysis was performed, and the diagnostic accuracy of shear wave elastography values was determined. Results: The mean shear wave elastography values of the optic nerves with neuritis (2.49 ± 0.41 m/s and 17.56 ± 4.42 kPa) were significantly higher than the values of the contralateral normal optic nerves (1.71 ± 0.32 m/s and 9.02 ± 2.34 kPa) (p = 0.006 and p = 0.004, respectively) in the optic neuritis group. The mean shear wave elastography values of intraorbital fat tissue adjacent optic nerves with neuritis (1.87 ± 0.32 m/s and 9.65 ± 1.12 kPa) were significantly higher than the values of the contralateral normal side (1.47 ± 0.27 m/s and 6.78 ± 1.14 kPa) (p = 0.025 and p = 0.022, respectively) in the optic neuritis group. ROC curve analysis showed a high diagnostic accuracy for determining optic neuritis with shear wave elastography values of the optic nerves (AUC 0.955 [95% CI, 0.933–0.978] in m/s and AUC 0.967 [95% CI, 0.940–0.985] in kPa). Conclusions: Shear wave elastography may be an important alternative diagnostic tool in the diagnosis of optic neuritis. Exeley Inc. 2021-08-16 2021-09-09 /pmc/articles/PMC8439124/ /pubmed/34540272 http://dx.doi.org/10.15557/JoU.2021.0031 Text en © Polish Ultrasound Society. Published by Medical Communications Sp. z o.o. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article licensed under the Creative Commons CC BY-NC-ND 4.0 license. https://creativecommons.org/licenses/by-nc-nd/4.0/
spellingShingle Medicine
Aybar, Mustafa Devran
Turna, Onder
Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
title Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
title_full Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
title_fullStr Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
title_full_unstemmed Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
title_short Shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
title_sort shear wave elastography in optic neuritis: diagnostic accuracy of the optic nerve and adjacent fat tissue values
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439124/
https://www.ncbi.nlm.nih.gov/pubmed/34540272
http://dx.doi.org/10.15557/JoU.2021.0031
work_keys_str_mv AT aybarmustafadevran shearwaveelastographyinopticneuritisdiagnosticaccuracyoftheopticnerveandadjacentfattissuevalues
AT turnaonder shearwaveelastographyinopticneuritisdiagnosticaccuracyoftheopticnerveandadjacentfattissuevalues