Cargando…
Correlation Between Trans-Stenotic Blood Flow Velocity Differences and the Cerebral Venous Pressure Gradient in Transverse Sinus Stenosis: A Prospective 4-Dimensional Flow Magnetic Resonance Imaging Study
BACKGROUND: The relationship between trans-stenotic blood flow velocity differences and the cerebral venous pressure gradient (CVPG) in transverse sinus (TS) stenosis (TSS) has not been studied. OBJECTIVE: To evaluate the hemodynamic manifestations of TSS and the relationship between trans-stenotic...
Autores principales: | Ding, Heyu, Zhao, Pengfei, Lv, Han, Li, Xiaoshuai, Qiu, Xiaoyu, Zeng, Rong, Wang, Guopeng, Yang, Zhenghan, Gong, Shusheng, Jin, Long, Wang, Zhenchang |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8440065/ https://www.ncbi.nlm.nih.gov/pubmed/34171923 http://dx.doi.org/10.1093/neuros/nyab222 |
Ejemplares similares
-
A new method for assessing transverse sinus stenosis with CT venography based on the venous trans-stenotic pressure gradient
por: Ding, Heyu, et al.
Publicado: (2023) -
The Relationships Among Transverse Sinus Stenosis Measured by CT Venography, Venous Trans-stenotic Pressure Gradient and Intracranial Pressure in Patients With Unilateral Venous Pulsatile Tinnitus
por: Qiu, Xiaoyu, et al.
Publicado: (2021) -
CT venography correlate of transverse sinus stenosis and venous transstenotic pressure gradient in unilateral pulsatile tinnitus patients with sigmoid sinus wall anomalies
por: Zhao, Pengfei, et al.
Publicado: (2020) -
Transverse Sinus Stenosis in Venous Pulsatile Tinnitus Patients May Lead to Brain Perfusion and White Matter Changes
por: Li, Xiaoshuai, et al.
Publicado: (2021) -
Effect of Emissary Vein on Hemodynamics of the Transverse- Sigmoid Sinus Junction
por: Qiu, Xiaoyu, et al.