Cargando…

Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)

INTRODUCTION: The FreeStyle Libre (FSL) is a flash glucose monitoring (FGM) system. The Flash Monitor Register in the Netherlands (FLARE-NL-4) study previously demonstrated the positive effects of FSL-FGM use during 1 year on glycemic control, quality of life and disease burden among persons with di...

Descripción completa

Detalles Bibliográficos
Autores principales: Lameijer, Annel, Fokkert, Marion J, Edens, Mireille A, Gans, Reinold O B, Bilo, Henk J G, van Dijk, Peter R
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8442047/
https://www.ncbi.nlm.nih.gov/pubmed/34521652
http://dx.doi.org/10.1136/bmjdrc-2021-002124
_version_ 1783752945847762944
author Lameijer, Annel
Fokkert, Marion J
Edens, Mireille A
Gans, Reinold O B
Bilo, Henk J G
van Dijk, Peter R
author_facet Lameijer, Annel
Fokkert, Marion J
Edens, Mireille A
Gans, Reinold O B
Bilo, Henk J G
van Dijk, Peter R
author_sort Lameijer, Annel
collection PubMed
description INTRODUCTION: The FreeStyle Libre (FSL) is a flash glucose monitoring (FGM) system. The Flash Monitor Register in the Netherlands (FLARE-NL-4) study previously demonstrated the positive effects of FSL-FGM use during 1 year on glycemic control, quality of life and disease burden among persons with diabetes mellitus (DM). The present follow-up study assesses the effects of FSL-FGM after 2 years. RESEARCH DESIGN AND METHODS: Patients included in the FLARE-NL-4 study who continued FSL-FGM during the 1-year study period were invited to participate (n=687). Data were collected using questionnaires (the 12-Item Short Form Health Survey version 2 (SF-12(v2)) and the EuroQol 5-Dimension 3-Level (EQ-5D-3L) for quality of life), including self-reported hemoglobin A1c (HbA1c). RESULTS: A total of 342 patients agreed to participate: mean age 48.0 (±15.6) years, 52% men and 79.5% with type 1 DM. HbA1c decreased from 60.7 (95% CI 59.1 to 62.3) mmol/mol before use of FSL-FGM to 57.3 (95% CI 55.8 to 58.8) mmol/mol after 1 year and 57.8 (95% CI 56.0 to 59.5) mmol/mol after 2 years. At the end of the 2-year follow-up period, 260 (76%) persons were still using the FSL-FGM and 82 (24%) had stopped. The main reason for stopping FSL-FGM was financial constraints (55%). Concerning the whole 2-year period, there was a significant decrease in HbA1c among persons who continued use of FSL-FGM (−3.5 mmol/mol, 95% CI −6.4 to –0.7), while HbA1c was unaltered compared with baseline among persons who stopped FSL-FGM (−2.4 mmol/mol, 95% CI −7.5 to 2.7): difference between groups 2.2 (95% CI −1.3 to 5.8) mmol/mol. After 2 years, persons who continued use of FSL-FGM had higher SF-12 mental component score and higher EQ-5D Dutch tariff score and felt less often anxious or depressed compared with persons who discontinued FSL-FGM. CONCLUSIONS: Although the considerable number of non-responders limits generalizability, this study suggests that persons who continue to use FSL-FGM for 2 years may experience sustained improvement in glycemic control and quality of life.
format Online
Article
Text
id pubmed-8442047
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-84420472021-09-29 Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6) Lameijer, Annel Fokkert, Marion J Edens, Mireille A Gans, Reinold O B Bilo, Henk J G van Dijk, Peter R BMJ Open Diabetes Res Care Emerging Technologies, Pharmacology and Therapeutics INTRODUCTION: The FreeStyle Libre (FSL) is a flash glucose monitoring (FGM) system. The Flash Monitor Register in the Netherlands (FLARE-NL-4) study previously demonstrated the positive effects of FSL-FGM use during 1 year on glycemic control, quality of life and disease burden among persons with diabetes mellitus (DM). The present follow-up study assesses the effects of FSL-FGM after 2 years. RESEARCH DESIGN AND METHODS: Patients included in the FLARE-NL-4 study who continued FSL-FGM during the 1-year study period were invited to participate (n=687). Data were collected using questionnaires (the 12-Item Short Form Health Survey version 2 (SF-12(v2)) and the EuroQol 5-Dimension 3-Level (EQ-5D-3L) for quality of life), including self-reported hemoglobin A1c (HbA1c). RESULTS: A total of 342 patients agreed to participate: mean age 48.0 (±15.6) years, 52% men and 79.5% with type 1 DM. HbA1c decreased from 60.7 (95% CI 59.1 to 62.3) mmol/mol before use of FSL-FGM to 57.3 (95% CI 55.8 to 58.8) mmol/mol after 1 year and 57.8 (95% CI 56.0 to 59.5) mmol/mol after 2 years. At the end of the 2-year follow-up period, 260 (76%) persons were still using the FSL-FGM and 82 (24%) had stopped. The main reason for stopping FSL-FGM was financial constraints (55%). Concerning the whole 2-year period, there was a significant decrease in HbA1c among persons who continued use of FSL-FGM (−3.5 mmol/mol, 95% CI −6.4 to –0.7), while HbA1c was unaltered compared with baseline among persons who stopped FSL-FGM (−2.4 mmol/mol, 95% CI −7.5 to 2.7): difference between groups 2.2 (95% CI −1.3 to 5.8) mmol/mol. After 2 years, persons who continued use of FSL-FGM had higher SF-12 mental component score and higher EQ-5D Dutch tariff score and felt less often anxious or depressed compared with persons who discontinued FSL-FGM. CONCLUSIONS: Although the considerable number of non-responders limits generalizability, this study suggests that persons who continue to use FSL-FGM for 2 years may experience sustained improvement in glycemic control and quality of life. BMJ Publishing Group 2021-09-14 /pmc/articles/PMC8442047/ /pubmed/34521652 http://dx.doi.org/10.1136/bmjdrc-2021-002124 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Emerging Technologies, Pharmacology and Therapeutics
Lameijer, Annel
Fokkert, Marion J
Edens, Mireille A
Gans, Reinold O B
Bilo, Henk J G
van Dijk, Peter R
Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)
title Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)
title_full Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)
title_fullStr Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)
title_full_unstemmed Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)
title_short Two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (FLARE-NL-6)
title_sort two-year use of flash glucose monitoring is associated with sustained improvement of glycemic control and quality of life (flare-nl-6)
topic Emerging Technologies, Pharmacology and Therapeutics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8442047/
https://www.ncbi.nlm.nih.gov/pubmed/34521652
http://dx.doi.org/10.1136/bmjdrc-2021-002124
work_keys_str_mv AT lameijerannel twoyearuseofflashglucosemonitoringisassociatedwithsustainedimprovementofglycemiccontrolandqualityoflifeflarenl6
AT fokkertmarionj twoyearuseofflashglucosemonitoringisassociatedwithsustainedimprovementofglycemiccontrolandqualityoflifeflarenl6
AT edensmireillea twoyearuseofflashglucosemonitoringisassociatedwithsustainedimprovementofglycemiccontrolandqualityoflifeflarenl6
AT gansreinoldob twoyearuseofflashglucosemonitoringisassociatedwithsustainedimprovementofglycemiccontrolandqualityoflifeflarenl6
AT bilohenkjg twoyearuseofflashglucosemonitoringisassociatedwithsustainedimprovementofglycemiccontrolandqualityoflifeflarenl6
AT vandijkpeterr twoyearuseofflashglucosemonitoringisassociatedwithsustainedimprovementofglycemiccontrolandqualityoflifeflarenl6