Cargando…

Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model

The development of new effective and safer therapies for osteoporosis, in addition to improved diagnostic and prevention strategies, represents a serious need in the scientific community. Micro-CT image-based analyses in association with biomechanical testing have become pivotal tools in identifying...

Descripción completa

Detalles Bibliográficos
Autores principales: Stephens, Maialen, López-Linares, Karen, Aldazabal, Javier, Macias, Iratxe, Ortuzar, Naiara, Bengoetxea, Harkaitz, Bulnes, Susana, Alcorta-Sevillano, Natividad, Infante, Arantza, Lafuente, Jose Vicente, Rodríguez, Clara I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8443718/
https://www.ncbi.nlm.nih.gov/pubmed/34526510
http://dx.doi.org/10.1038/s41597-021-01012-8
_version_ 1784568343639883776
author Stephens, Maialen
López-Linares, Karen
Aldazabal, Javier
Macias, Iratxe
Ortuzar, Naiara
Bengoetxea, Harkaitz
Bulnes, Susana
Alcorta-Sevillano, Natividad
Infante, Arantza
Lafuente, Jose Vicente
Rodríguez, Clara I.
author_facet Stephens, Maialen
López-Linares, Karen
Aldazabal, Javier
Macias, Iratxe
Ortuzar, Naiara
Bengoetxea, Harkaitz
Bulnes, Susana
Alcorta-Sevillano, Natividad
Infante, Arantza
Lafuente, Jose Vicente
Rodríguez, Clara I.
author_sort Stephens, Maialen
collection PubMed
description The development of new effective and safer therapies for osteoporosis, in addition to improved diagnostic and prevention strategies, represents a serious need in the scientific community. Micro-CT image-based analyses in association with biomechanical testing have become pivotal tools in identifying osteoporosis in animal models by assessment of bone microarchitecture and resistance, as well as bone strength. Here, we describe a dataset of micro-CT scans and reconstructions of 15 whole femurs and biomechanical tests on contralateral femurs from C57BL/6JOlaHsd ovariectomized (OVX), resembling human post-menopausal osteoporosis, and sham operated (sham) female mice. Data provided for each mouse include: the acquisition images (.tiff), the reconstructed images (.bmp) and an.xls file containing the maximum attenuations for each reconstructed image. Biomechanical data include an.xls file with the recorded load-displacement, a movie with the filmed test and an.xls file collecting all biomechanical results.
format Online
Article
Text
id pubmed-8443718
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-84437182021-10-04 Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model Stephens, Maialen López-Linares, Karen Aldazabal, Javier Macias, Iratxe Ortuzar, Naiara Bengoetxea, Harkaitz Bulnes, Susana Alcorta-Sevillano, Natividad Infante, Arantza Lafuente, Jose Vicente Rodríguez, Clara I. Sci Data Data Descriptor The development of new effective and safer therapies for osteoporosis, in addition to improved diagnostic and prevention strategies, represents a serious need in the scientific community. Micro-CT image-based analyses in association with biomechanical testing have become pivotal tools in identifying osteoporosis in animal models by assessment of bone microarchitecture and resistance, as well as bone strength. Here, we describe a dataset of micro-CT scans and reconstructions of 15 whole femurs and biomechanical tests on contralateral femurs from C57BL/6JOlaHsd ovariectomized (OVX), resembling human post-menopausal osteoporosis, and sham operated (sham) female mice. Data provided for each mouse include: the acquisition images (.tiff), the reconstructed images (.bmp) and an.xls file containing the maximum attenuations for each reconstructed image. Biomechanical data include an.xls file with the recorded load-displacement, a movie with the filmed test and an.xls file collecting all biomechanical results. Nature Publishing Group UK 2021-09-15 /pmc/articles/PMC8443718/ /pubmed/34526510 http://dx.doi.org/10.1038/s41597-021-01012-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) applies to the metadata files associated with this article.
spellingShingle Data Descriptor
Stephens, Maialen
López-Linares, Karen
Aldazabal, Javier
Macias, Iratxe
Ortuzar, Naiara
Bengoetxea, Harkaitz
Bulnes, Susana
Alcorta-Sevillano, Natividad
Infante, Arantza
Lafuente, Jose Vicente
Rodríguez, Clara I.
Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
title Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
title_full Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
title_fullStr Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
title_full_unstemmed Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
title_short Murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
title_sort murine femur micro-computed tomography and biomechanical datasets for an ovariectomy-induced osteoporosis model
topic Data Descriptor
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8443718/
https://www.ncbi.nlm.nih.gov/pubmed/34526510
http://dx.doi.org/10.1038/s41597-021-01012-8
work_keys_str_mv AT stephensmaialen murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT lopezlinareskaren murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT aldazabaljavier murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT maciasiratxe murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT ortuzarnaiara murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT bengoetxeaharkaitz murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT bulnessusana murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT alcortasevillanonatividad murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT infantearantza murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT lafuentejosevicente murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel
AT rodriguezclarai murinefemurmicrocomputedtomographyandbiomechanicaldatasetsforanovariectomyinducedosteoporosismodel