Cargando…
Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center
INTRODUCTION: Ionizing radiation-producing equipment is used in surgical centers to guide invasive procedures. Technological advances have enabled improvements in image quality, which may be accompanied by increased radiation doses in the surgical team. Correct use of personal protective equipment a...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Associação Nacional de Medicina do Trabalho (ANAMT)
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8447647/ https://www.ncbi.nlm.nih.gov/pubmed/34603412 http://dx.doi.org/10.47626/1679-4435-2021-576 |
_version_ | 1784569062168199168 |
---|---|
author | Cury, Caio Santiloni Alves, Allan Felipe Fattori Mascarenhas, Yvone Maria Magon, Maria de Fátima Ruiz Jr, Raul Lopes Trindade Filho, José Carlos de Souza Camargo, Lucas Faconi Pina, Diana Rodrigues |
author_facet | Cury, Caio Santiloni Alves, Allan Felipe Fattori Mascarenhas, Yvone Maria Magon, Maria de Fátima Ruiz Jr, Raul Lopes Trindade Filho, José Carlos de Souza Camargo, Lucas Faconi Pina, Diana Rodrigues |
author_sort | Cury, Caio Santiloni |
collection | PubMed |
description | INTRODUCTION: Ionizing radiation-producing equipment is used in surgical centers to guide invasive procedures. Technological advances have enabled improvements in image quality, which may be accompanied by increased radiation doses in the surgical team. Correct use of personal protective equipment and monitoring of radiation levels are required to a safe practice. OBJECTIVES: To evaluate radiation exposure conditions in occupationally exposed persons working at the Surgical Center at Hospital das Clínicas da Faculdade de Medicina de Botucatu for implementation of radiation protection measures. METHODS: Three different types of fluoroscopy equipment were used: C-arms, a dosimetric system with ionization chambers, and optically stimulated dosimeters. A three-stage evaluation was conducted, consisting of a first stage for observation, a second stage for estimation of kerma rate simulating exposure conditions, and a final stage for dosimetry to estimate the effective dose in workers. RESULTS: The most frequent procedures and the disposition for each team member were determined. Kerma values were estimated for both the principal physician and the assistant physician. The maximum number of annual procedures was also estimated so that the dose limits are not exceeded. CONCLUSIONS: Dosimetry for the surgical team is indicated as an approach to monitor occupational dose levels. The dose rates and effective dose found in this study are low but not negligible. Thus, proper use of equipment and periodic training for workers are still the best options for radiation protection. |
format | Online Article Text |
id | pubmed-8447647 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Associação Nacional de Medicina do Trabalho (ANAMT) |
record_format | MEDLINE/PubMed |
spelling | pubmed-84476472021-09-30 Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center Cury, Caio Santiloni Alves, Allan Felipe Fattori Mascarenhas, Yvone Maria Magon, Maria de Fátima Ruiz Jr, Raul Lopes Trindade Filho, José Carlos de Souza Camargo, Lucas Faconi Pina, Diana Rodrigues Rev Bras Med Trab Original Article INTRODUCTION: Ionizing radiation-producing equipment is used in surgical centers to guide invasive procedures. Technological advances have enabled improvements in image quality, which may be accompanied by increased radiation doses in the surgical team. Correct use of personal protective equipment and monitoring of radiation levels are required to a safe practice. OBJECTIVES: To evaluate radiation exposure conditions in occupationally exposed persons working at the Surgical Center at Hospital das Clínicas da Faculdade de Medicina de Botucatu for implementation of radiation protection measures. METHODS: Three different types of fluoroscopy equipment were used: C-arms, a dosimetric system with ionization chambers, and optically stimulated dosimeters. A three-stage evaluation was conducted, consisting of a first stage for observation, a second stage for estimation of kerma rate simulating exposure conditions, and a final stage for dosimetry to estimate the effective dose in workers. RESULTS: The most frequent procedures and the disposition for each team member were determined. Kerma values were estimated for both the principal physician and the assistant physician. The maximum number of annual procedures was also estimated so that the dose limits are not exceeded. CONCLUSIONS: Dosimetry for the surgical team is indicated as an approach to monitor occupational dose levels. The dose rates and effective dose found in this study are low but not negligible. Thus, proper use of equipment and periodic training for workers are still the best options for radiation protection. Associação Nacional de Medicina do Trabalho (ANAMT) 2021-08-04 /pmc/articles/PMC8447647/ /pubmed/34603412 http://dx.doi.org/10.47626/1679-4435-2021-576 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial No Derivative License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium provided the original work is properly cited and the work is not changed in any way. |
spellingShingle | Original Article Cury, Caio Santiloni Alves, Allan Felipe Fattori Mascarenhas, Yvone Maria Magon, Maria de Fátima Ruiz Jr, Raul Lopes Trindade Filho, José Carlos de Souza Camargo, Lucas Faconi Pina, Diana Rodrigues Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
title | Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
title_full | Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
title_fullStr | Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
title_full_unstemmed | Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
title_short | Evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
title_sort | evaluation of exposure of a multidisciplinary team to ionizing radiation due to the use of fluoroscopy equipment in a surgical center |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8447647/ https://www.ncbi.nlm.nih.gov/pubmed/34603412 http://dx.doi.org/10.47626/1679-4435-2021-576 |
work_keys_str_mv | AT curycaiosantiloni evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT alvesallanfelipefattori evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT mascarenhasyvonemaria evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT magonmariadefatima evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT ruizjrraullopes evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT trindadefilhojosecarlosdesouza evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT camargolucasfaconi evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter AT pinadianarodrigues evaluationofexposureofamultidisciplinaryteamtoionizingradiationduetotheuseoffluoroscopyequipmentinasurgicalcenter |