Cargando…

Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system

PURPOSE: Total hip arthroplasties (THAs) are rising worldwide, as the functional request of patients who undergo this procedure. The trabeculae oriented pattern (TOP) is a modern cup, which follows the philosophy of the tissue sparing surgery (TSS). Focusing on clinical and radiological results and...

Descripción completa

Detalles Bibliográficos
Autores principales: Mosconi, L., Cavagnaro, L., Zanirato, A., Quarto, E., Lontaro Baracchini, M., Formica, M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Paris 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8448675/
https://www.ncbi.nlm.nih.gov/pubmed/33660047
http://dx.doi.org/10.1007/s00590-021-02917-1
_version_ 1784569285929074688
author Mosconi, L.
Cavagnaro, L.
Zanirato, A.
Quarto, E.
Lontaro Baracchini, M.
Formica, M.
author_facet Mosconi, L.
Cavagnaro, L.
Zanirato, A.
Quarto, E.
Lontaro Baracchini, M.
Formica, M.
author_sort Mosconi, L.
collection PubMed
description PURPOSE: Total hip arthroplasties (THAs) are rising worldwide, as the functional request of patients who undergo this procedure. The trabeculae oriented pattern (TOP) is a modern cup, which follows the philosophy of the tissue sparing surgery (TSS). Focusing on clinical and radiological results and complications, the authors aim to highlight the outcomes of the TOP at a long-term follow-up (FU). METHODS: A retrospective analysis was completed on THA performed with the TOP cup between 1997 and 2015. Five hundred and eighty-eight patients sustained surgery, for a total of 662 cup implanted. Four hundred and sixty patients (524 hips) were examined. Mean FU was 12 ± 4.9 years (range 5–22). Clinical (HHS, OHS and VAS) and radiological data were obtained. Every complication, reoperation or revision was recorded and analyzed. RESULTS: Clinical evaluation revealed a HHS of 87.1 ± 13.8 an OHS of 41.3 ± 5.4, and a VAS of 1.2 ± 1.1. Acetabular osteolysis was observed in 53 hips. Overall survival rate of the cup was 90.5% (50 revisions), the main causes of cup substitution being aseptic loosening (AL) of the cup combined with the stem (26), of the cup only (13 cases) and periprosthetic joint infection (7 cases). CONCLUSION: TOP cup has demonstrated a good overall survivorship at a long-term FU, even compared with other coated cups, providing excellent clinical result with low rate of complications. Its association with a neck sparing stem permits a physiologic load transmission, reducing the stress shielding effect that could cause early implant mobilization.
format Online
Article
Text
id pubmed-8448675
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Paris
record_format MEDLINE/PubMed
spelling pubmed-84486752021-10-01 Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system Mosconi, L. Cavagnaro, L. Zanirato, A. Quarto, E. Lontaro Baracchini, M. Formica, M. Eur J Orthop Surg Traumatol Original Article PURPOSE: Total hip arthroplasties (THAs) are rising worldwide, as the functional request of patients who undergo this procedure. The trabeculae oriented pattern (TOP) is a modern cup, which follows the philosophy of the tissue sparing surgery (TSS). Focusing on clinical and radiological results and complications, the authors aim to highlight the outcomes of the TOP at a long-term follow-up (FU). METHODS: A retrospective analysis was completed on THA performed with the TOP cup between 1997 and 2015. Five hundred and eighty-eight patients sustained surgery, for a total of 662 cup implanted. Four hundred and sixty patients (524 hips) were examined. Mean FU was 12 ± 4.9 years (range 5–22). Clinical (HHS, OHS and VAS) and radiological data were obtained. Every complication, reoperation or revision was recorded and analyzed. RESULTS: Clinical evaluation revealed a HHS of 87.1 ± 13.8 an OHS of 41.3 ± 5.4, and a VAS of 1.2 ± 1.1. Acetabular osteolysis was observed in 53 hips. Overall survival rate of the cup was 90.5% (50 revisions), the main causes of cup substitution being aseptic loosening (AL) of the cup combined with the stem (26), of the cup only (13 cases) and periprosthetic joint infection (7 cases). CONCLUSION: TOP cup has demonstrated a good overall survivorship at a long-term FU, even compared with other coated cups, providing excellent clinical result with low rate of complications. Its association with a neck sparing stem permits a physiologic load transmission, reducing the stress shielding effect that could cause early implant mobilization. Springer Paris 2021-03-03 2021 /pmc/articles/PMC8448675/ /pubmed/33660047 http://dx.doi.org/10.1007/s00590-021-02917-1 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Mosconi, L.
Cavagnaro, L.
Zanirato, A.
Quarto, E.
Lontaro Baracchini, M.
Formica, M.
Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system
title Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system
title_full Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system
title_fullStr Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system
title_full_unstemmed Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system
title_short Long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (T.O.P.) acetabular system
title_sort long-term follow-up of a low profile, coated, press-fit cup: the trabeculae oriented pattern (t.o.p.) acetabular system
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8448675/
https://www.ncbi.nlm.nih.gov/pubmed/33660047
http://dx.doi.org/10.1007/s00590-021-02917-1
work_keys_str_mv AT mosconil longtermfollowupofalowprofilecoatedpressfitcupthetrabeculaeorientedpatterntopacetabularsystem
AT cavagnarol longtermfollowupofalowprofilecoatedpressfitcupthetrabeculaeorientedpatterntopacetabularsystem
AT zaniratoa longtermfollowupofalowprofilecoatedpressfitcupthetrabeculaeorientedpatterntopacetabularsystem
AT quartoe longtermfollowupofalowprofilecoatedpressfitcupthetrabeculaeorientedpatterntopacetabularsystem
AT lontarobaracchinim longtermfollowupofalowprofilecoatedpressfitcupthetrabeculaeorientedpatterntopacetabularsystem
AT formicam longtermfollowupofalowprofilecoatedpressfitcupthetrabeculaeorientedpatterntopacetabularsystem