Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
The new Abbott Alinity m STI Assay was compared with Abbott m2000 RealTime PCR. For Chlamydia trachomatis, 26 (7.5%) of 347 samples were positive in the Alinity assay and 24 (6.9%) in the m2000 assay. Corresponding figures for Neisseria gonorrhoeae were 23 (6.6%) and 17 (4.9%). For Mycoplasma genita...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8449771/ https://www.ncbi.nlm.nih.gov/pubmed/33723736 http://dx.doi.org/10.1007/s10096-020-04135-9 |
_version_ | 1784569488981622784 |
---|---|
author | Herrmann, Björn Malm, Karin |
author_facet | Herrmann, Björn Malm, Karin |
author_sort | Herrmann, Björn |
collection | PubMed |
description | The new Abbott Alinity m STI Assay was compared with Abbott m2000 RealTime PCR. For Chlamydia trachomatis, 26 (7.5%) of 347 samples were positive in the Alinity assay and 24 (6.9%) in the m2000 assay. Corresponding figures for Neisseria gonorrhoeae were 23 (6.6%) and 17 (4.9%). For Mycoplasma genitalium, 22 (7.9%) of 279 samples were positive in the Alinity assay and 18 (6.5%) in the m2000 assay, for which DNA extraction was performed on an m2000sp instrument combined with in-house real-time PCR. The Alinity assay has at least the same sensitivity as the m2000 assay. The specificity was evaluated by discrepancy analysis. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-020-04135-9. |
format | Online Article Text |
id | pubmed-8449771 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-84497712021-10-01 Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium Herrmann, Björn Malm, Karin Eur J Clin Microbiol Infect Dis Brief Report The new Abbott Alinity m STI Assay was compared with Abbott m2000 RealTime PCR. For Chlamydia trachomatis, 26 (7.5%) of 347 samples were positive in the Alinity assay and 24 (6.9%) in the m2000 assay. Corresponding figures for Neisseria gonorrhoeae were 23 (6.6%) and 17 (4.9%). For Mycoplasma genitalium, 22 (7.9%) of 279 samples were positive in the Alinity assay and 18 (6.5%) in the m2000 assay, for which DNA extraction was performed on an m2000sp instrument combined with in-house real-time PCR. The Alinity assay has at least the same sensitivity as the m2000 assay. The specificity was evaluated by discrepancy analysis. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-020-04135-9. Springer Berlin Heidelberg 2021-03-15 2021 /pmc/articles/PMC8449771/ /pubmed/33723736 http://dx.doi.org/10.1007/s10096-020-04135-9 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Brief Report Herrmann, Björn Malm, Karin Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium |
title | Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium |
title_full | Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium |
title_fullStr | Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium |
title_full_unstemmed | Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium |
title_short | Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium |
title_sort | comparison between abbott m2000 realtime and alinity m sti systems for detection of chlamydia trachomatis, neisseria gonorrhoeae, and mycoplasma genitalium |
topic | Brief Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8449771/ https://www.ncbi.nlm.nih.gov/pubmed/33723736 http://dx.doi.org/10.1007/s10096-020-04135-9 |
work_keys_str_mv | AT herrmannbjorn comparisonbetweenabbottm2000realtimeandalinitymstisystemsfordetectionofchlamydiatrachomatisneisseriagonorrhoeaeandmycoplasmagenitalium AT malmkarin comparisonbetweenabbottm2000realtimeandalinitymstisystemsfordetectionofchlamydiatrachomatisneisseriagonorrhoeaeandmycoplasmagenitalium |