Cargando…

Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium

The new Abbott Alinity m STI Assay was compared with Abbott m2000 RealTime PCR. For Chlamydia trachomatis, 26 (7.5%) of 347 samples were positive in the Alinity assay and 24 (6.9%) in the m2000 assay. Corresponding figures for Neisseria gonorrhoeae were 23 (6.6%) and 17 (4.9%). For Mycoplasma genita...

Descripción completa

Detalles Bibliográficos
Autores principales: Herrmann, Björn, Malm, Karin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8449771/
https://www.ncbi.nlm.nih.gov/pubmed/33723736
http://dx.doi.org/10.1007/s10096-020-04135-9
_version_ 1784569488981622784
author Herrmann, Björn
Malm, Karin
author_facet Herrmann, Björn
Malm, Karin
author_sort Herrmann, Björn
collection PubMed
description The new Abbott Alinity m STI Assay was compared with Abbott m2000 RealTime PCR. For Chlamydia trachomatis, 26 (7.5%) of 347 samples were positive in the Alinity assay and 24 (6.9%) in the m2000 assay. Corresponding figures for Neisseria gonorrhoeae were 23 (6.6%) and 17 (4.9%). For Mycoplasma genitalium, 22 (7.9%) of 279 samples were positive in the Alinity assay and 18 (6.5%) in the m2000 assay, for which DNA extraction was performed on an m2000sp instrument combined with in-house real-time PCR. The Alinity assay has at least the same sensitivity as the m2000 assay. The specificity was evaluated by discrepancy analysis. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-020-04135-9.
format Online
Article
Text
id pubmed-8449771
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-84497712021-10-01 Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium Herrmann, Björn Malm, Karin Eur J Clin Microbiol Infect Dis Brief Report The new Abbott Alinity m STI Assay was compared with Abbott m2000 RealTime PCR. For Chlamydia trachomatis, 26 (7.5%) of 347 samples were positive in the Alinity assay and 24 (6.9%) in the m2000 assay. Corresponding figures for Neisseria gonorrhoeae were 23 (6.6%) and 17 (4.9%). For Mycoplasma genitalium, 22 (7.9%) of 279 samples were positive in the Alinity assay and 18 (6.5%) in the m2000 assay, for which DNA extraction was performed on an m2000sp instrument combined with in-house real-time PCR. The Alinity assay has at least the same sensitivity as the m2000 assay. The specificity was evaluated by discrepancy analysis. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10096-020-04135-9. Springer Berlin Heidelberg 2021-03-15 2021 /pmc/articles/PMC8449771/ /pubmed/33723736 http://dx.doi.org/10.1007/s10096-020-04135-9 Text en © The Author(s) 2020 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Brief Report
Herrmann, Björn
Malm, Karin
Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
title Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
title_full Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
title_fullStr Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
title_full_unstemmed Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
title_short Comparison between Abbott m2000 RealTime and Alinity m STI systems for detection of Chlamydia trachomatis, Neisseria gonorrhoeae, and Mycoplasma genitalium
title_sort comparison between abbott m2000 realtime and alinity m sti systems for detection of chlamydia trachomatis, neisseria gonorrhoeae, and mycoplasma genitalium
topic Brief Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8449771/
https://www.ncbi.nlm.nih.gov/pubmed/33723736
http://dx.doi.org/10.1007/s10096-020-04135-9
work_keys_str_mv AT herrmannbjorn comparisonbetweenabbottm2000realtimeandalinitymstisystemsfordetectionofchlamydiatrachomatisneisseriagonorrhoeaeandmycoplasmagenitalium
AT malmkarin comparisonbetweenabbottm2000realtimeandalinitymstisystemsfordetectionofchlamydiatrachomatisneisseriagonorrhoeaeandmycoplasmagenitalium