Cargando…

Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks

Background: Night-time heart rate (HR) is expected to reflect more accurately the cardiac autonomic function of modulating cardiovascular activity. Few studies have been conducted on the predictive values of night-time HR in relation to cardioverter-defibrillator therapies. Aims: To explore the asso...

Descripción completa

Detalles Bibliográficos
Autores principales: Sun, Xuerong, Zhou, Bin, Chen, Keping, Hua, Wei, Su, Yangang, Xu, Wei, Wang, Fang, Fan, Xiaohan, Niu, Hongxia, Dai, Yan, Liu, Zhimin, Zhao, Shuang, Zhang, Shu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8450398/
https://www.ncbi.nlm.nih.gov/pubmed/34552968
http://dx.doi.org/10.3389/fcvm.2021.739889
_version_ 1784569636552966144
author Sun, Xuerong
Zhou, Bin
Chen, Keping
Hua, Wei
Su, Yangang
Xu, Wei
Wang, Fang
Fan, Xiaohan
Niu, Hongxia
Dai, Yan
Liu, Zhimin
Zhao, Shuang
Zhang, Shu
author_facet Sun, Xuerong
Zhou, Bin
Chen, Keping
Hua, Wei
Su, Yangang
Xu, Wei
Wang, Fang
Fan, Xiaohan
Niu, Hongxia
Dai, Yan
Liu, Zhimin
Zhao, Shuang
Zhang, Shu
author_sort Sun, Xuerong
collection PubMed
description Background: Night-time heart rate (HR) is expected to reflect more accurately the cardiac autonomic function of modulating cardiovascular activity. Few studies have been conducted on the predictive values of night-time HR in relation to cardioverter-defibrillator therapies. Aims: To explore the associations of night-time HR with the ventricular tachyarrhythmias (VTAs), appropriate and inappropriate implantable cardioverter-defibrillator (ICD) shocks. Methods: Patients from the SUMMIT registry receiving ICD or cardiac resynchronization therapy with defibrillator (CRT-D) implantation were retrospectively analyzed using archived home monitoring data. Night-time HR was recorded from 2:00 am to 6:00 am during the first 30 to 60 days after implantation. VTA events and ICD shocks were identified using the intracardiac electrograms by two independent physicians. Restricted cubic splines and smooth curve fitting were conducted to address the non-linear associations between night-time HR and adjusted hazards for clinical outcomes. Results: Over a mean follow-up duration of 55.8 ± 22.7 months, 187 deaths were observed among 730 patients. VTAs, appropriate and inappropriate ICD shocks were observed in 422 (57.8%), 293 (40.1%), and 72 (10.0%) patients, respectively. Apparent U-shaped non-linear associations of night-time HR with VTAs (P for non-linearity = 0.007), appropriate ICD shocks (P for non-linearity = 0.003) and inappropriate ICD shocks (P for non-linearity = 0.014) were detected. When night-time HR was beyond 60 bpm, every 1 bpm increase in night-time HR could result in 3.2, 3.3, and 4.9% higher risks of VTAs and appropriate and inappropriate ICD shocks, respectively; when night-time HR was lower than 60 bpm, every 1 bpm increase in night-time HR could result in 6.0 and 10.7% lower risks of appropriate and inappropriate ICD shocks. Compared to night-time HR of ≤ 50 or ≥70 bpm, night-time HR of 50–70 bpm was associated with 24.9, 30.2, 63.5, and 31.5% reduced incidences of VTA events, appropriate ICD shocks, inappropriate ICD shocks, and all-cause mortality, respectively. Conclusion: Apparent non-linear associations of night-time HR with VTAs and ICD shocks were detected. An increasing incidence of VTAs and ICD shocks was observed at both low and high levels of night-time HR. Night-time HR of 50–70 bpm might be the optimal therapeutics target for the management of ICD/CRT-D recipients.
format Online
Article
Text
id pubmed-8450398
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-84503982021-09-21 Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks Sun, Xuerong Zhou, Bin Chen, Keping Hua, Wei Su, Yangang Xu, Wei Wang, Fang Fan, Xiaohan Niu, Hongxia Dai, Yan Liu, Zhimin Zhao, Shuang Zhang, Shu Front Cardiovasc Med Cardiovascular Medicine Background: Night-time heart rate (HR) is expected to reflect more accurately the cardiac autonomic function of modulating cardiovascular activity. Few studies have been conducted on the predictive values of night-time HR in relation to cardioverter-defibrillator therapies. Aims: To explore the associations of night-time HR with the ventricular tachyarrhythmias (VTAs), appropriate and inappropriate implantable cardioverter-defibrillator (ICD) shocks. Methods: Patients from the SUMMIT registry receiving ICD or cardiac resynchronization therapy with defibrillator (CRT-D) implantation were retrospectively analyzed using archived home monitoring data. Night-time HR was recorded from 2:00 am to 6:00 am during the first 30 to 60 days after implantation. VTA events and ICD shocks were identified using the intracardiac electrograms by two independent physicians. Restricted cubic splines and smooth curve fitting were conducted to address the non-linear associations between night-time HR and adjusted hazards for clinical outcomes. Results: Over a mean follow-up duration of 55.8 ± 22.7 months, 187 deaths were observed among 730 patients. VTAs, appropriate and inappropriate ICD shocks were observed in 422 (57.8%), 293 (40.1%), and 72 (10.0%) patients, respectively. Apparent U-shaped non-linear associations of night-time HR with VTAs (P for non-linearity = 0.007), appropriate ICD shocks (P for non-linearity = 0.003) and inappropriate ICD shocks (P for non-linearity = 0.014) were detected. When night-time HR was beyond 60 bpm, every 1 bpm increase in night-time HR could result in 3.2, 3.3, and 4.9% higher risks of VTAs and appropriate and inappropriate ICD shocks, respectively; when night-time HR was lower than 60 bpm, every 1 bpm increase in night-time HR could result in 6.0 and 10.7% lower risks of appropriate and inappropriate ICD shocks. Compared to night-time HR of ≤ 50 or ≥70 bpm, night-time HR of 50–70 bpm was associated with 24.9, 30.2, 63.5, and 31.5% reduced incidences of VTA events, appropriate ICD shocks, inappropriate ICD shocks, and all-cause mortality, respectively. Conclusion: Apparent non-linear associations of night-time HR with VTAs and ICD shocks were detected. An increasing incidence of VTAs and ICD shocks was observed at both low and high levels of night-time HR. Night-time HR of 50–70 bpm might be the optimal therapeutics target for the management of ICD/CRT-D recipients. Frontiers Media S.A. 2021-09-06 /pmc/articles/PMC8450398/ /pubmed/34552968 http://dx.doi.org/10.3389/fcvm.2021.739889 Text en Copyright © 2021 Sun, Zhou, Chen, Hua, Su, Xu, Wang, Fan, Niu, Dai, Liu, Zhao and Zhang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Sun, Xuerong
Zhou, Bin
Chen, Keping
Hua, Wei
Su, Yangang
Xu, Wei
Wang, Fang
Fan, Xiaohan
Niu, Hongxia
Dai, Yan
Liu, Zhimin
Zhao, Shuang
Zhang, Shu
Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks
title Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks
title_full Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks
title_fullStr Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks
title_full_unstemmed Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks
title_short Association of Night-Time Heart Rate With Ventricular Tachyarrhythmias, Appropriate and Inappropriate Implantable Cardioverter-Defibrillator Shocks
title_sort association of night-time heart rate with ventricular tachyarrhythmias, appropriate and inappropriate implantable cardioverter-defibrillator shocks
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8450398/
https://www.ncbi.nlm.nih.gov/pubmed/34552968
http://dx.doi.org/10.3389/fcvm.2021.739889
work_keys_str_mv AT sunxuerong associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT zhoubin associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT chenkeping associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT huawei associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT suyangang associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT xuwei associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT wangfang associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT fanxiaohan associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT niuhongxia associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT daiyan associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT liuzhimin associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT zhaoshuang associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks
AT zhangshu associationofnighttimeheartratewithventriculartachyarrhythmiasappropriateandinappropriateimplantablecardioverterdefibrillatorshocks