Cargando…

Three-dimensional microengineered vascularised endometrium-on-a-chip

STUDY QUESTION: Can we reconstitute physiologically relevant 3-dimensional (3D) microengineered endometrium in-vitro model? SUMMARY ANSWER: Our representative microengineered vascularised endometrium on-a-chip closely recapitulates the endometrial microenvironment that consists of three distinct lay...

Descripción completa

Detalles Bibliográficos
Autores principales: Ahn, Jungho, Yoon, Min-Ji, Hong, Seon-Hwa, Cha, Hwijae, Lee, Danbi, Koo, Hwa Seon, Ko, Ji-Eun, Lee, Jungseub, Oh, Soojung, Jeon, Noo Li, Kang, Youn-Jung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8450871/
https://www.ncbi.nlm.nih.gov/pubmed/34363466
http://dx.doi.org/10.1093/humrep/deab186
_version_ 1784569732264886272
author Ahn, Jungho
Yoon, Min-Ji
Hong, Seon-Hwa
Cha, Hwijae
Lee, Danbi
Koo, Hwa Seon
Ko, Ji-Eun
Lee, Jungseub
Oh, Soojung
Jeon, Noo Li
Kang, Youn-Jung
author_facet Ahn, Jungho
Yoon, Min-Ji
Hong, Seon-Hwa
Cha, Hwijae
Lee, Danbi
Koo, Hwa Seon
Ko, Ji-Eun
Lee, Jungseub
Oh, Soojung
Jeon, Noo Li
Kang, Youn-Jung
author_sort Ahn, Jungho
collection PubMed
description STUDY QUESTION: Can we reconstitute physiologically relevant 3-dimensional (3D) microengineered endometrium in-vitro model? SUMMARY ANSWER: Our representative microengineered vascularised endometrium on-a-chip closely recapitulates the endometrial microenvironment that consists of three distinct layers including epithelial cells, stromal fibroblasts and endothelial cells in a 3D extracellular matrix in a spatiotemporal manner. WHAT IS KNOWN ALREADY: Organ-on-a-chip, a multi-channel 3D microfluidic cell culture system, is widely used to investigate physiologically relevant responses of organ systems. STUDY DESIGN, SIZE, DURATION: The device consists of five microchannels that are arrayed in parallel and partitioned by array of micropost. Two central channels are for 3D culture and morphogenesis of stromal fibroblast and endothelial cells. In addition, the outermost channel is for the culture of additional endometrial stromal fibroblasts that secrete biochemical cues to induce directional pro-angiogenic responses of endothelial cells. To seed endometrial epithelial cells, on Day 8, Ishikawa cells were introduced to one of the two medium channels to adhere on the gel surface. After that, the microengineered endometrium was cultured for an additional 5–6 days (total ∼ 14 days) for the purpose of each experiment. PARTICIPANTS/MATERIALS, SETTING, METHODS: Microfluidic 3D cultures were maintained in endothelial growth Medium 2 with or without oestradiol and progesterone. Some cultures additionally received exogenous pro-angiogenic factors. For the three distinct layers of microengineered endometrium-on-a-chip, the epithelium, stroma and blood vessel characteristics and drug response of each distinct layer in the microfluidic model were assessed morphologically and biochemically. The quantitative measurement of endometrial drug delivery was evaluated by the permeability coefficients. MAIN RESULTS AND THE ROLE OF CHANCE: We established microengineered vascularised endometrium-on-chip, which consists of three distinct layers: epithelium, stroma and blood vessels. Our endometrium model faithfully recapitulates in-vivo endometrial vasculo-angiogenesis and hormonal responses displaying key features of the proliferative and secretory phases of the menstrual cycle. Furthermore, the effect of the emergency contraception drug levonorgestrel was evaluated in our model demonstrating increased endometrial permeability and blood vessel regression in a dose-dependent manner. We finally provided a proof of concept of the multi-layered endometrium model for embryo implantation, which aids a better understanding of the molecular and cellular mechanisms underlying this process. LARGE SCALE DATA: N/A. LIMITATIONS, REASONS FOR CAUTION: This report is largely an in-vitro study and it would be beneficial to validate our findings using human primary endometrial cells. WIDER IMPLICATIONS OF THE FINDINGS: Our 3D microengineered vascularised endometrium-on-a-chip provides a new in-vitro approach to drug screening and drug discovery by mimicking the complicated behaviours of human endometrium. Thus, we suggest our model as a tool for addressing critical challenges and unsolved problems in female diseases, such as endometriosis, uterine cancer and female infertility, in a personalised manner. STUDY FUNDING/COMPETING INTEREST(S): This work is supported by funding from the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) to Y.J.K. (No. 2018R1C1B6003), to J.A. (No. 2020R1I1A1A01074136) and to H.S.K. (No. 2020R1C1C100787212). The authors report no conflicts of interest.
format Online
Article
Text
id pubmed-8450871
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-84508712021-09-22 Three-dimensional microengineered vascularised endometrium-on-a-chip Ahn, Jungho Yoon, Min-Ji Hong, Seon-Hwa Cha, Hwijae Lee, Danbi Koo, Hwa Seon Ko, Ji-Eun Lee, Jungseub Oh, Soojung Jeon, Noo Li Kang, Youn-Jung Hum Reprod Original Articles STUDY QUESTION: Can we reconstitute physiologically relevant 3-dimensional (3D) microengineered endometrium in-vitro model? SUMMARY ANSWER: Our representative microengineered vascularised endometrium on-a-chip closely recapitulates the endometrial microenvironment that consists of three distinct layers including epithelial cells, stromal fibroblasts and endothelial cells in a 3D extracellular matrix in a spatiotemporal manner. WHAT IS KNOWN ALREADY: Organ-on-a-chip, a multi-channel 3D microfluidic cell culture system, is widely used to investigate physiologically relevant responses of organ systems. STUDY DESIGN, SIZE, DURATION: The device consists of five microchannels that are arrayed in parallel and partitioned by array of micropost. Two central channels are for 3D culture and morphogenesis of stromal fibroblast and endothelial cells. In addition, the outermost channel is for the culture of additional endometrial stromal fibroblasts that secrete biochemical cues to induce directional pro-angiogenic responses of endothelial cells. To seed endometrial epithelial cells, on Day 8, Ishikawa cells were introduced to one of the two medium channels to adhere on the gel surface. After that, the microengineered endometrium was cultured for an additional 5–6 days (total ∼ 14 days) for the purpose of each experiment. PARTICIPANTS/MATERIALS, SETTING, METHODS: Microfluidic 3D cultures were maintained in endothelial growth Medium 2 with or without oestradiol and progesterone. Some cultures additionally received exogenous pro-angiogenic factors. For the three distinct layers of microengineered endometrium-on-a-chip, the epithelium, stroma and blood vessel characteristics and drug response of each distinct layer in the microfluidic model were assessed morphologically and biochemically. The quantitative measurement of endometrial drug delivery was evaluated by the permeability coefficients. MAIN RESULTS AND THE ROLE OF CHANCE: We established microengineered vascularised endometrium-on-chip, which consists of three distinct layers: epithelium, stroma and blood vessels. Our endometrium model faithfully recapitulates in-vivo endometrial vasculo-angiogenesis and hormonal responses displaying key features of the proliferative and secretory phases of the menstrual cycle. Furthermore, the effect of the emergency contraception drug levonorgestrel was evaluated in our model demonstrating increased endometrial permeability and blood vessel regression in a dose-dependent manner. We finally provided a proof of concept of the multi-layered endometrium model for embryo implantation, which aids a better understanding of the molecular and cellular mechanisms underlying this process. LARGE SCALE DATA: N/A. LIMITATIONS, REASONS FOR CAUTION: This report is largely an in-vitro study and it would be beneficial to validate our findings using human primary endometrial cells. WIDER IMPLICATIONS OF THE FINDINGS: Our 3D microengineered vascularised endometrium-on-a-chip provides a new in-vitro approach to drug screening and drug discovery by mimicking the complicated behaviours of human endometrium. Thus, we suggest our model as a tool for addressing critical challenges and unsolved problems in female diseases, such as endometriosis, uterine cancer and female infertility, in a personalised manner. STUDY FUNDING/COMPETING INTEREST(S): This work is supported by funding from the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) to Y.J.K. (No. 2018R1C1B6003), to J.A. (No. 2020R1I1A1A01074136) and to H.S.K. (No. 2020R1C1C100787212). The authors report no conflicts of interest. Oxford University Press 2021-08-07 /pmc/articles/PMC8450871/ /pubmed/34363466 http://dx.doi.org/10.1093/humrep/deab186 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of European Society of Human Reproduction and Embryology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Original Articles
Ahn, Jungho
Yoon, Min-Ji
Hong, Seon-Hwa
Cha, Hwijae
Lee, Danbi
Koo, Hwa Seon
Ko, Ji-Eun
Lee, Jungseub
Oh, Soojung
Jeon, Noo Li
Kang, Youn-Jung
Three-dimensional microengineered vascularised endometrium-on-a-chip
title Three-dimensional microengineered vascularised endometrium-on-a-chip
title_full Three-dimensional microengineered vascularised endometrium-on-a-chip
title_fullStr Three-dimensional microengineered vascularised endometrium-on-a-chip
title_full_unstemmed Three-dimensional microengineered vascularised endometrium-on-a-chip
title_short Three-dimensional microengineered vascularised endometrium-on-a-chip
title_sort three-dimensional microengineered vascularised endometrium-on-a-chip
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8450871/
https://www.ncbi.nlm.nih.gov/pubmed/34363466
http://dx.doi.org/10.1093/humrep/deab186
work_keys_str_mv AT ahnjungho threedimensionalmicroengineeredvascularisedendometriumonachip
AT yoonminji threedimensionalmicroengineeredvascularisedendometriumonachip
AT hongseonhwa threedimensionalmicroengineeredvascularisedendometriumonachip
AT chahwijae threedimensionalmicroengineeredvascularisedendometriumonachip
AT leedanbi threedimensionalmicroengineeredvascularisedendometriumonachip
AT koohwaseon threedimensionalmicroengineeredvascularisedendometriumonachip
AT kojieun threedimensionalmicroengineeredvascularisedendometriumonachip
AT leejungseub threedimensionalmicroengineeredvascularisedendometriumonachip
AT ohsoojung threedimensionalmicroengineeredvascularisedendometriumonachip
AT jeonnooli threedimensionalmicroengineeredvascularisedendometriumonachip
AT kangyounjung threedimensionalmicroengineeredvascularisedendometriumonachip