Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system

BACKGROUND: DYMIND DH76 (DYMIND BIOTECH, China) is a new automated hematology system designed to provide CBC count, including a 5-part WBC differential count, and its analytical performance should be assessed before adoption for clinical use. METHODS: The analyzer was evaluated according to the Inte...

Descripción completa

Detalles Bibliográficos
Autores principales: Velizarova, Milena, Yacheva, Teodora, Genova, Mariana, Svinarov, Dobrin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Society of Medical Biochemists of Serbia, Belgrade 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451233/
https://www.ncbi.nlm.nih.gov/pubmed/34616226
http://dx.doi.org/10.5937/jomb0-28836
_version_ 1784569800402403328
author Velizarova, Milena
Yacheva, Teodora
Genova, Mariana
Svinarov, Dobrin
author_facet Velizarova, Milena
Yacheva, Teodora
Genova, Mariana
Svinarov, Dobrin
author_sort Velizarova, Milena
collection PubMed
description BACKGROUND: DYMIND DH76 (DYMIND BIOTECH, China) is a new automated hematology system designed to provide CBC count, including a 5-part WBC differential count, and its analytical performance should be assessed before adoption for clinical use. METHODS: The analyzer was evaluated according to the International Council for Standardization in Haematology guideline. The purposes of this study were to assess its analytical performance in comparison to SYSMEX XN 1000 hematology analyzer currently used in our laboratory, as well as to compare the automated and manual WBC differential. RESULTS: Within-run precision in all concentration ranges was very good with coefficients of variation (CVs) between 0.02% and 2.5% except for platelets over 500×109/L (CV 9.5%). Within-batch imprecision showed CVs lower the declared deviation ranges. Accuracy (defined as trueness) was excellent for all CBC and white cell differential parameters, compared with the state of the art%. Linearity was confirmed with excellent regression coefficients (0.999-1.000), even in the lowest values, and carryover was ≤ 1%. Comparison between DYMIND DH76 and SYSMEX XN 1000 was also very good with correlation coefficients (R2) for WBC (1.000), RBC (0.999), hemoglobin (0.999) and PLT over 50×10(9)/L (0.994) and R2 was lower but still acceptable (0.910) for PLT<50×10(9)/L. R2 for neutrophils, lymphocytes, eosinophils, basophils, and monocytes were 0.974, 0.982, 0.957, 0.625, and 0.836, respectively, in the comparison between the manual and DYMIND DH76 automated differential WBC counts. CONCLUSIONS: With excellent analytical performance and acceptable comparative analysis, DYMIND DH76 hematology analyser covered the predefined international standards and requirements and is fully appropriate for clinical application.
format Online
Article
Text
id pubmed-8451233
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Society of Medical Biochemists of Serbia, Belgrade
record_format MEDLINE/PubMed
spelling pubmed-84512332021-10-05 Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system Velizarova, Milena Yacheva, Teodora Genova, Mariana Svinarov, Dobrin J Med Biochem Original Paper BACKGROUND: DYMIND DH76 (DYMIND BIOTECH, China) is a new automated hematology system designed to provide CBC count, including a 5-part WBC differential count, and its analytical performance should be assessed before adoption for clinical use. METHODS: The analyzer was evaluated according to the International Council for Standardization in Haematology guideline. The purposes of this study were to assess its analytical performance in comparison to SYSMEX XN 1000 hematology analyzer currently used in our laboratory, as well as to compare the automated and manual WBC differential. RESULTS: Within-run precision in all concentration ranges was very good with coefficients of variation (CVs) between 0.02% and 2.5% except for platelets over 500×109/L (CV 9.5%). Within-batch imprecision showed CVs lower the declared deviation ranges. Accuracy (defined as trueness) was excellent for all CBC and white cell differential parameters, compared with the state of the art%. Linearity was confirmed with excellent regression coefficients (0.999-1.000), even in the lowest values, and carryover was ≤ 1%. Comparison between DYMIND DH76 and SYSMEX XN 1000 was also very good with correlation coefficients (R2) for WBC (1.000), RBC (0.999), hemoglobin (0.999) and PLT over 50×10(9)/L (0.994) and R2 was lower but still acceptable (0.910) for PLT<50×10(9)/L. R2 for neutrophils, lymphocytes, eosinophils, basophils, and monocytes were 0.974, 0.982, 0.957, 0.625, and 0.836, respectively, in the comparison between the manual and DYMIND DH76 automated differential WBC counts. CONCLUSIONS: With excellent analytical performance and acceptable comparative analysis, DYMIND DH76 hematology analyser covered the predefined international standards and requirements and is fully appropriate for clinical application. Society of Medical Biochemists of Serbia, Belgrade 2021-09-03 2021-09-03 /pmc/articles/PMC8451233/ /pubmed/34616226 http://dx.doi.org/10.5937/jomb0-28836 Text en 2021 Milena Velizarova, Teodora Yacheva, Mariana Genova, Dobrin Svinarov, published by CEON/CEES https://creativecommons.org/licenses/by/4.0/This work is licensed under the Creative Commons Attribution 4.0 License.
spellingShingle Original Paper
Velizarova, Milena
Yacheva, Teodora
Genova, Mariana
Svinarov, Dobrin
Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system
title Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system
title_full Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system
title_fullStr Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system
title_full_unstemmed Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system
title_short Evaluation of automated hematology analyzer DYMIND DH76 compared to SYSMEX XN 1000 system
title_sort evaluation of automated hematology analyzer dymind dh76 compared to sysmex xn 1000 system
topic Original Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451233/
https://www.ncbi.nlm.nih.gov/pubmed/34616226
http://dx.doi.org/10.5937/jomb0-28836
work_keys_str_mv AT velizarovamilena evaluationofautomatedhematologyanalyzerdyminddh76comparedtosysmexxn1000system
AT yachevateodora evaluationofautomatedhematologyanalyzerdyminddh76comparedtosysmexxn1000system
AT genovamariana evaluationofautomatedhematologyanalyzerdyminddh76comparedtosysmexxn1000system
AT svinarovdobrin evaluationofautomatedhematologyanalyzerdyminddh76comparedtosysmexxn1000system