Cargando…

Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance

BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcu...

Descripción completa

Detalles Bibliográficos
Autores principales: Buhl, Rikke, Nissen, Sarah D., Winther, Marie L. K., Poulsen, Sofie K., Hopster‐Iversen, Charlotte, Jespersen, Thomas, Sanders, Prashanthan, Carstensen, Helena, Hesselkilde, Eva M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451893/
https://www.ncbi.nlm.nih.gov/pubmed/33113157
http://dx.doi.org/10.1111/evj.13372
_version_ 1784569949099917312
author Buhl, Rikke
Nissen, Sarah D.
Winther, Marie L. K.
Poulsen, Sofie K.
Hopster‐Iversen, Charlotte
Jespersen, Thomas
Sanders, Prashanthan
Carstensen, Helena
Hesselkilde, Eva M.
author_facet Buhl, Rikke
Nissen, Sarah D.
Winther, Marie L. K.
Poulsen, Sofie K.
Hopster‐Iversen, Charlotte
Jespersen, Thomas
Sanders, Prashanthan
Carstensen, Helena
Hesselkilde, Eva M.
author_sort Buhl, Rikke
collection PubMed
description BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. OBJECTIVES: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. STUDY DESIGN: Prospective field study. METHODS: Twelve racing Standardbred trotters with intermittent reduced performance (mean age: six years) were enrolled prospectively. The ILR was implanted subcutaneously at the fifth or sixth left intercostal space and data from the ILR was collected during the study period in which the horses were followed for a median duration of 7.5 month (range 6‐28). RESULTS: The ILR was able to detect PAF in four out of twelve racehorses. The ILR also detected sustained atrial fibrillation (AF) in one horse during the study. The ILRs rely on RR detection and R waves were correctly identified in 96%. One hundred episodes were categorised as AF by the ILRs and subsequently visual ECG inspection categorised 12 as sinus rhythm (SR), 28 as sinus arrhythmia (SA), 14 as other arrhythmias and 46 as AF episodes. The Root Mean Square of the Successive Differences (RMSSD) values were significantly increased for AF compared to SR and SA. MAIN LIMITATIONS: Few horses included and duration of study period varied among the horses. Further it was not possible to assess the sensitivity of the device in the current study and the ILRs proved to have a high rate of false positive misclassifications. CONCLUSIONS: This study indicates that ILRs can be used for detection of PAF episodes and could be a useful ECG tool for horses presenting with poor performance. This methodology provides a platform to facilitate the long‐term assessment of AF development and quantification of AF burden in horses. Further studies including both healthy and poor performing horses are needed in order to learn more about PAF prevalence in racehorses.
format Online
Article
Text
id pubmed-8451893
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-84518932021-09-27 Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance Buhl, Rikke Nissen, Sarah D. Winther, Marie L. K. Poulsen, Sofie K. Hopster‐Iversen, Charlotte Jespersen, Thomas Sanders, Prashanthan Carstensen, Helena Hesselkilde, Eva M. Equine Vet J Descriptive Clinical Reports BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. OBJECTIVES: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. STUDY DESIGN: Prospective field study. METHODS: Twelve racing Standardbred trotters with intermittent reduced performance (mean age: six years) were enrolled prospectively. The ILR was implanted subcutaneously at the fifth or sixth left intercostal space and data from the ILR was collected during the study period in which the horses were followed for a median duration of 7.5 month (range 6‐28). RESULTS: The ILR was able to detect PAF in four out of twelve racehorses. The ILR also detected sustained atrial fibrillation (AF) in one horse during the study. The ILRs rely on RR detection and R waves were correctly identified in 96%. One hundred episodes were categorised as AF by the ILRs and subsequently visual ECG inspection categorised 12 as sinus rhythm (SR), 28 as sinus arrhythmia (SA), 14 as other arrhythmias and 46 as AF episodes. The Root Mean Square of the Successive Differences (RMSSD) values were significantly increased for AF compared to SR and SA. MAIN LIMITATIONS: Few horses included and duration of study period varied among the horses. Further it was not possible to assess the sensitivity of the device in the current study and the ILRs proved to have a high rate of false positive misclassifications. CONCLUSIONS: This study indicates that ILRs can be used for detection of PAF episodes and could be a useful ECG tool for horses presenting with poor performance. This methodology provides a platform to facilitate the long‐term assessment of AF development and quantification of AF burden in horses. Further studies including both healthy and poor performing horses are needed in order to learn more about PAF prevalence in racehorses. John Wiley and Sons Inc. 2020-11-23 2021-09 /pmc/articles/PMC8451893/ /pubmed/33113157 http://dx.doi.org/10.1111/evj.13372 Text en © 2020 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Descriptive Clinical Reports
Buhl, Rikke
Nissen, Sarah D.
Winther, Marie L. K.
Poulsen, Sofie K.
Hopster‐Iversen, Charlotte
Jespersen, Thomas
Sanders, Prashanthan
Carstensen, Helena
Hesselkilde, Eva M.
Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
title Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
title_full Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
title_fullStr Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
title_full_unstemmed Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
title_short Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
title_sort implantable loop recorders can detect paroxysmal atrial fibrillation in standardbred racehorses with intermittent poor performance
topic Descriptive Clinical Reports
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451893/
https://www.ncbi.nlm.nih.gov/pubmed/33113157
http://dx.doi.org/10.1111/evj.13372
work_keys_str_mv AT buhlrikke implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT nissensarahd implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT winthermarielk implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT poulsensofiek implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT hopsteriversencharlotte implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT jespersenthomas implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT sandersprashanthan implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT carstensenhelena implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance
AT hesselkildeevam implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance