Cargando…
Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance
BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcu...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451893/ https://www.ncbi.nlm.nih.gov/pubmed/33113157 http://dx.doi.org/10.1111/evj.13372 |
_version_ | 1784569949099917312 |
---|---|
author | Buhl, Rikke Nissen, Sarah D. Winther, Marie L. K. Poulsen, Sofie K. Hopster‐Iversen, Charlotte Jespersen, Thomas Sanders, Prashanthan Carstensen, Helena Hesselkilde, Eva M. |
author_facet | Buhl, Rikke Nissen, Sarah D. Winther, Marie L. K. Poulsen, Sofie K. Hopster‐Iversen, Charlotte Jespersen, Thomas Sanders, Prashanthan Carstensen, Helena Hesselkilde, Eva M. |
author_sort | Buhl, Rikke |
collection | PubMed |
description | BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. OBJECTIVES: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. STUDY DESIGN: Prospective field study. METHODS: Twelve racing Standardbred trotters with intermittent reduced performance (mean age: six years) were enrolled prospectively. The ILR was implanted subcutaneously at the fifth or sixth left intercostal space and data from the ILR was collected during the study period in which the horses were followed for a median duration of 7.5 month (range 6‐28). RESULTS: The ILR was able to detect PAF in four out of twelve racehorses. The ILR also detected sustained atrial fibrillation (AF) in one horse during the study. The ILRs rely on RR detection and R waves were correctly identified in 96%. One hundred episodes were categorised as AF by the ILRs and subsequently visual ECG inspection categorised 12 as sinus rhythm (SR), 28 as sinus arrhythmia (SA), 14 as other arrhythmias and 46 as AF episodes. The Root Mean Square of the Successive Differences (RMSSD) values were significantly increased for AF compared to SR and SA. MAIN LIMITATIONS: Few horses included and duration of study period varied among the horses. Further it was not possible to assess the sensitivity of the device in the current study and the ILRs proved to have a high rate of false positive misclassifications. CONCLUSIONS: This study indicates that ILRs can be used for detection of PAF episodes and could be a useful ECG tool for horses presenting with poor performance. This methodology provides a platform to facilitate the long‐term assessment of AF development and quantification of AF burden in horses. Further studies including both healthy and poor performing horses are needed in order to learn more about PAF prevalence in racehorses. |
format | Online Article Text |
id | pubmed-8451893 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2020 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84518932021-09-27 Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance Buhl, Rikke Nissen, Sarah D. Winther, Marie L. K. Poulsen, Sofie K. Hopster‐Iversen, Charlotte Jespersen, Thomas Sanders, Prashanthan Carstensen, Helena Hesselkilde, Eva M. Equine Vet J Descriptive Clinical Reports BACKGROUND: Limited information is available on paroxysmal atrial fibrillation (PAF) in the horse. Indeed, undiagnosed PAF could result in poor performance. Due to the intermittent occurrence, PAF is difficult to diagnose. However, implanting a small ECG device (implantable loop recorder, ILR) subcutaneously, allows the continuous and automatic detection of PAF. OBJECTIVES: The aim was to investigate the potential of ILRs as a tool for diagnosing PAF in horses with poor performance. STUDY DESIGN: Prospective field study. METHODS: Twelve racing Standardbred trotters with intermittent reduced performance (mean age: six years) were enrolled prospectively. The ILR was implanted subcutaneously at the fifth or sixth left intercostal space and data from the ILR was collected during the study period in which the horses were followed for a median duration of 7.5 month (range 6‐28). RESULTS: The ILR was able to detect PAF in four out of twelve racehorses. The ILR also detected sustained atrial fibrillation (AF) in one horse during the study. The ILRs rely on RR detection and R waves were correctly identified in 96%. One hundred episodes were categorised as AF by the ILRs and subsequently visual ECG inspection categorised 12 as sinus rhythm (SR), 28 as sinus arrhythmia (SA), 14 as other arrhythmias and 46 as AF episodes. The Root Mean Square of the Successive Differences (RMSSD) values were significantly increased for AF compared to SR and SA. MAIN LIMITATIONS: Few horses included and duration of study period varied among the horses. Further it was not possible to assess the sensitivity of the device in the current study and the ILRs proved to have a high rate of false positive misclassifications. CONCLUSIONS: This study indicates that ILRs can be used for detection of PAF episodes and could be a useful ECG tool for horses presenting with poor performance. This methodology provides a platform to facilitate the long‐term assessment of AF development and quantification of AF burden in horses. Further studies including both healthy and poor performing horses are needed in order to learn more about PAF prevalence in racehorses. John Wiley and Sons Inc. 2020-11-23 2021-09 /pmc/articles/PMC8451893/ /pubmed/33113157 http://dx.doi.org/10.1111/evj.13372 Text en © 2020 The Authors. Equine Veterinary Journal published by John Wiley & Sons Ltd on behalf of EVJ Ltd https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Descriptive Clinical Reports Buhl, Rikke Nissen, Sarah D. Winther, Marie L. K. Poulsen, Sofie K. Hopster‐Iversen, Charlotte Jespersen, Thomas Sanders, Prashanthan Carstensen, Helena Hesselkilde, Eva M. Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance |
title | Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance |
title_full | Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance |
title_fullStr | Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance |
title_full_unstemmed | Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance |
title_short | Implantable loop recorders can detect paroxysmal atrial fibrillation in Standardbred racehorses with intermittent poor performance |
title_sort | implantable loop recorders can detect paroxysmal atrial fibrillation in standardbred racehorses with intermittent poor performance |
topic | Descriptive Clinical Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451893/ https://www.ncbi.nlm.nih.gov/pubmed/33113157 http://dx.doi.org/10.1111/evj.13372 |
work_keys_str_mv | AT buhlrikke implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT nissensarahd implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT winthermarielk implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT poulsensofiek implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT hopsteriversencharlotte implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT jespersenthomas implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT sandersprashanthan implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT carstensenhelena implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance AT hesselkildeevam implantablelooprecorderscandetectparoxysmalatrialfibrillationinstandardbredracehorseswithintermittentpoorperformance |