Cargando…
Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent
The SureID®S6 system used a lyophilized pellet as the amplification reagent to enable multiplexing of sex-determining marker Amelogenin, 21 autosomal short tandem repeats (STRs), and one Y-STR. To assess the performance, reliability, and limitation of the dry amplification system, the validation stu...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451954/ https://www.ncbi.nlm.nih.gov/pubmed/34552616 http://dx.doi.org/10.3389/fgene.2021.705819 |
_version_ | 1784569963265130496 |
---|---|
author | Li, Shuanglin Lin, Jinfeng Hao, Honglei Jin, Haiying Song, Danlu Zhu, Bofeng |
author_facet | Li, Shuanglin Lin, Jinfeng Hao, Honglei Jin, Haiying Song, Danlu Zhu, Bofeng |
author_sort | Li, Shuanglin |
collection | PubMed |
description | The SureID®S6 system used a lyophilized pellet as the amplification reagent to enable multiplexing of sex-determining marker Amelogenin, 21 autosomal short tandem repeats (STRs), and one Y-STR. To assess the performance, reliability, and limitation of the dry amplification system, the validation studies including PCR condition, reproducibility, sizing and precision, analytical threshold calculation, sensitivity and stochastic threshold calculation, species specificity, stability, mixture, case sample, and population and concordance were conducted according to the Scientific Working Group on DNA Analysis Methods (SWGDAM) Validation Guidelines. Experimental data suggested that the optimal range of total input DNA was from 125 to 500 pg; the appropriate analytical threshold was 80 relative fluorescence units (RFUs) while the stochastic threshold was 260 RFUs; for the stability studies, SureID®S6 system could resist against less than 500 μmol/L of hematin, 100 ng/μl of humic acid, 4 mM of indigotin, 800 mM of tannic acid, and 800 mM of calcium ion. Population and concordance studies using 500 unrelated individuals showed that the combined probability of discrimination (CPD) and cumulative probability of exclusion (CPE) values were 0.999999999999 and 0.999999998416, respectively. The genotypes for the same sample were concordant with the previously validated HUAXIA™ Platinum kit. The validation results demonstrated that the SureID®S6 system could be used for forensic applifications. |
format | Online Article Text |
id | pubmed-8451954 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-84519542021-09-21 Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent Li, Shuanglin Lin, Jinfeng Hao, Honglei Jin, Haiying Song, Danlu Zhu, Bofeng Front Genet Genetics The SureID®S6 system used a lyophilized pellet as the amplification reagent to enable multiplexing of sex-determining marker Amelogenin, 21 autosomal short tandem repeats (STRs), and one Y-STR. To assess the performance, reliability, and limitation of the dry amplification system, the validation studies including PCR condition, reproducibility, sizing and precision, analytical threshold calculation, sensitivity and stochastic threshold calculation, species specificity, stability, mixture, case sample, and population and concordance were conducted according to the Scientific Working Group on DNA Analysis Methods (SWGDAM) Validation Guidelines. Experimental data suggested that the optimal range of total input DNA was from 125 to 500 pg; the appropriate analytical threshold was 80 relative fluorescence units (RFUs) while the stochastic threshold was 260 RFUs; for the stability studies, SureID®S6 system could resist against less than 500 μmol/L of hematin, 100 ng/μl of humic acid, 4 mM of indigotin, 800 mM of tannic acid, and 800 mM of calcium ion. Population and concordance studies using 500 unrelated individuals showed that the combined probability of discrimination (CPD) and cumulative probability of exclusion (CPE) values were 0.999999999999 and 0.999999998416, respectively. The genotypes for the same sample were concordant with the previously validated HUAXIA™ Platinum kit. The validation results demonstrated that the SureID®S6 system could be used for forensic applifications. Frontiers Media S.A. 2021-09-06 /pmc/articles/PMC8451954/ /pubmed/34552616 http://dx.doi.org/10.3389/fgene.2021.705819 Text en Copyright © 2021 Li, Lin, Hao, Jin, Song and Zhu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Genetics Li, Shuanglin Lin, Jinfeng Hao, Honglei Jin, Haiying Song, Danlu Zhu, Bofeng Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent |
title | Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent |
title_full | Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent |
title_fullStr | Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent |
title_full_unstemmed | Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent |
title_short | Validation of a 6-Dye Short Tandem Repeat System: A Dry Kit With Lyophilized Amplification Reagent |
title_sort | validation of a 6-dye short tandem repeat system: a dry kit with lyophilized amplification reagent |
topic | Genetics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8451954/ https://www.ncbi.nlm.nih.gov/pubmed/34552616 http://dx.doi.org/10.3389/fgene.2021.705819 |
work_keys_str_mv | AT lishuanglin validationofa6dyeshorttandemrepeatsystemadrykitwithlyophilizedamplificationreagent AT linjinfeng validationofa6dyeshorttandemrepeatsystemadrykitwithlyophilizedamplificationreagent AT haohonglei validationofa6dyeshorttandemrepeatsystemadrykitwithlyophilizedamplificationreagent AT jinhaiying validationofa6dyeshorttandemrepeatsystemadrykitwithlyophilizedamplificationreagent AT songdanlu validationofa6dyeshorttandemrepeatsystemadrykitwithlyophilizedamplificationreagent AT zhubofeng validationofa6dyeshorttandemrepeatsystemadrykitwithlyophilizedamplificationreagent |