Cargando…
Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients
BACKGROUND: In vivo corneal biomechanics evaluation has been used to help screen early keratoconus in recent years. This study is to evaluate the value of a Scheimpflug-based biomechanical analyser combined with tomography in detecting subclinical keratoconus by distinguishing normal eyes from frank...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8454178/ https://www.ncbi.nlm.nih.gov/pubmed/34544392 http://dx.doi.org/10.1186/s12886-021-02102-2 |
_version_ | 1784570436860772352 |
---|---|
author | Liu, Yan Zhang, Yu Chen, Yueguo |
author_facet | Liu, Yan Zhang, Yu Chen, Yueguo |
author_sort | Liu, Yan |
collection | PubMed |
description | BACKGROUND: In vivo corneal biomechanics evaluation has been used to help screen early keratoconus in recent years. This study is to evaluate the value of a Scheimpflug-based biomechanical analyser combined with tomography in detecting subclinical keratoconus by distinguishing normal eyes from frank keratoconus (KC) and forme frusta keratoconus (FFKC) eyes in Chinese patients. METHODS: Study design: diagnostic test. This study included 31 bilateral frank keratoconus patients, 27 unilateral clinically manifesting keratoconus patients with very asymmetric eyes, and 79 control subjects with normal corneas. Corneal morphological and biomechanical parameters were measured using a Pentacam HR and a Corvis ST (OCULUS, Wetzlar, Germany). The diagnostic ability of computed parameters reflecting corneal biomechanical and morphological traits [including the Belin-Ambrósio deviation index (BAD_D), the Corvis biomechanical index (CBI) and the tomographic and biomechanical index (TBI)] was determined using receiver operating characteristic (ROC) curve analysis and compared by the DeLong test. Additionally, the area under the curve (AUC), the best cut-off values, and the Youden index for each parameter were reported. A novel corneal stiffness parameter, the stress-strain index (SSI), was also compared between KC, FFKC and normal eyes. RESULTS: Every morphological and biomechanical index analysed in this study was significantly different among KC, FFKC and normal eyes (P = 0.000). The TBI was most valuable in detecting subclinical keratoconus (FFKC eyes), with an AUC of 0.928 (P = 0.000), and both forms of corneal ectasia (FFKC and frank KC eyes), with an AUC of 0.966 (P = 0.000). The sensitivity and specificity of the TBI was 97.5 and 77.8 % in detecting FFKC and 97.5 and 89.7 % in detecting any KC, respectively, with a cut-off value of 0.375. The morphological index BAD_D and the biomechanical index CBI were also very useful in distinguishing eyes with any KC from normal eyes, with AUCs of 0.965 and 0.934, respectively. The SSI was significantly different between KC, FFKC and normal eyes (P = 0.000), indicating an independent decrease in corneal stiffness in KC eyes. CONCLUSIONS: The combination of a Scheimpflug-based biomechanical analyser and tomography could increase the accuracy in detecting subclinical keratoconus in Chinese patients. The TBI was the most valuable index for detecting subclinical keratoconus, with a high sensitivity and specificity. Evaluation of corneal biomechanical properties in refractive surgery candidates could be helpful for recognizing potential keratoconic eyes and increasing surgical safety. |
format | Online Article Text |
id | pubmed-8454178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-84541782021-09-21 Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients Liu, Yan Zhang, Yu Chen, Yueguo BMC Ophthalmol Research Article BACKGROUND: In vivo corneal biomechanics evaluation has been used to help screen early keratoconus in recent years. This study is to evaluate the value of a Scheimpflug-based biomechanical analyser combined with tomography in detecting subclinical keratoconus by distinguishing normal eyes from frank keratoconus (KC) and forme frusta keratoconus (FFKC) eyes in Chinese patients. METHODS: Study design: diagnostic test. This study included 31 bilateral frank keratoconus patients, 27 unilateral clinically manifesting keratoconus patients with very asymmetric eyes, and 79 control subjects with normal corneas. Corneal morphological and biomechanical parameters were measured using a Pentacam HR and a Corvis ST (OCULUS, Wetzlar, Germany). The diagnostic ability of computed parameters reflecting corneal biomechanical and morphological traits [including the Belin-Ambrósio deviation index (BAD_D), the Corvis biomechanical index (CBI) and the tomographic and biomechanical index (TBI)] was determined using receiver operating characteristic (ROC) curve analysis and compared by the DeLong test. Additionally, the area under the curve (AUC), the best cut-off values, and the Youden index for each parameter were reported. A novel corneal stiffness parameter, the stress-strain index (SSI), was also compared between KC, FFKC and normal eyes. RESULTS: Every morphological and biomechanical index analysed in this study was significantly different among KC, FFKC and normal eyes (P = 0.000). The TBI was most valuable in detecting subclinical keratoconus (FFKC eyes), with an AUC of 0.928 (P = 0.000), and both forms of corneal ectasia (FFKC and frank KC eyes), with an AUC of 0.966 (P = 0.000). The sensitivity and specificity of the TBI was 97.5 and 77.8 % in detecting FFKC and 97.5 and 89.7 % in detecting any KC, respectively, with a cut-off value of 0.375. The morphological index BAD_D and the biomechanical index CBI were also very useful in distinguishing eyes with any KC from normal eyes, with AUCs of 0.965 and 0.934, respectively. The SSI was significantly different between KC, FFKC and normal eyes (P = 0.000), indicating an independent decrease in corneal stiffness in KC eyes. CONCLUSIONS: The combination of a Scheimpflug-based biomechanical analyser and tomography could increase the accuracy in detecting subclinical keratoconus in Chinese patients. The TBI was the most valuable index for detecting subclinical keratoconus, with a high sensitivity and specificity. Evaluation of corneal biomechanical properties in refractive surgery candidates could be helpful for recognizing potential keratoconic eyes and increasing surgical safety. BioMed Central 2021-09-20 /pmc/articles/PMC8454178/ /pubmed/34544392 http://dx.doi.org/10.1186/s12886-021-02102-2 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Article Liu, Yan Zhang, Yu Chen, Yueguo Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
title | Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
title_full | Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
title_fullStr | Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
title_full_unstemmed | Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
title_short | Application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
title_sort | application of a scheimpflug-based biomechanical analyser and tomography in the early detection of subclinical keratoconus in chinese patients |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8454178/ https://www.ncbi.nlm.nih.gov/pubmed/34544392 http://dx.doi.org/10.1186/s12886-021-02102-2 |
work_keys_str_mv | AT liuyan applicationofascheimpflugbasedbiomechanicalanalyserandtomographyintheearlydetectionofsubclinicalkeratoconusinchinesepatients AT zhangyu applicationofascheimpflugbasedbiomechanicalanalyserandtomographyintheearlydetectionofsubclinicalkeratoconusinchinesepatients AT chenyueguo applicationofascheimpflugbasedbiomechanicalanalyserandtomographyintheearlydetectionofsubclinicalkeratoconusinchinesepatients |