Cargando…
Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking
BACKGROUND: A shock-absorbing pylon (SAP) is a modular prosthetic component designed to attenuate impact forces, which unlike traditional pylons that are rigid, can compress to absorb, return, or dissipate energy. Previous studies found that walking with a SAP improved lower-limb prosthesis users’ c...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8456590/ https://www.ncbi.nlm.nih.gov/pubmed/34548080 http://dx.doi.org/10.1186/s12984-021-00939-8 |
_version_ | 1784570897579900928 |
---|---|
author | Maun, Jenny Anne Gard, Steven A. Major, Matthew J. Takahashi, Kota Z. |
author_facet | Maun, Jenny Anne Gard, Steven A. Major, Matthew J. Takahashi, Kota Z. |
author_sort | Maun, Jenny Anne |
collection | PubMed |
description | BACKGROUND: A shock-absorbing pylon (SAP) is a modular prosthetic component designed to attenuate impact forces, which unlike traditional pylons that are rigid, can compress to absorb, return, or dissipate energy. Previous studies found that walking with a SAP improved lower-limb prosthesis users’ comfort and residual limb pain. While longitudinal stiffness of a SAP has been shown to affect gait kinematics, kinetics, and work done by the entire lower limb, the energetic contributions from the prosthesis and the intact joints have not been examined. The purpose of this study was to determine the effects of SAP stiffness and walking speed on the mechanical work contributions of the prosthesis (i.e., all components distal to socket), knee, and hip in individuals with a transtibial amputation. METHODS: Twelve participants with unilateral transtibial amputation walked overground at their customary (1.22 ± 0.18 ms(−1)) and fast speeds (1.53 ± 0.29 ms(−1)) under four different levels of SAP stiffness. Power and mechanical work profiles of the leg joints and components distal to the socket were quantified. The effects of SAP stiffness and walking speed on positive and negative work were analyzed using two-factor (stiffness and speed) repeated-measure ANOVAs (α = 0.05). RESULTS: Faster walking significantly increased mechanical work from the SAP-integrated prosthesis (p < 0.001). Reducing SAP stiffness increased the magnitude of prosthesis negative work (energy absorption) during early stance (p = 0.045) by as much as 0.027 Jkg(−1), without affecting the positive work (energy return) during late stance (p = 0.159), suggesting a damping effect. This energy loss was partially offset by an increase in residual hip positive work (as much as 0.012 Jkg(−1)) during late stance (p = 0.045). Reducing SAP stiffness also reduced the magnitude of negative work on the contralateral sound limb during early stance by 11–17% (p = 0.001). CONCLUSIONS: Reducing SAP stiffness and faster walking amplified the prostheses damping effect, which redistributed the mechanical work, both in magnitude and timing, within the residual joints and sound limb. With its capacity to absorb and dissipate energy, future studies are warranted to determine whether SAPs can provide additional user benefit for locomotor tasks that require greater attenuation of impact forces (e.g., load carriage) or energy dissipation (e.g., downhill walking). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12984-021-00939-8. |
format | Online Article Text |
id | pubmed-8456590 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-84565902021-09-22 Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking Maun, Jenny Anne Gard, Steven A. Major, Matthew J. Takahashi, Kota Z. J Neuroeng Rehabil Research BACKGROUND: A shock-absorbing pylon (SAP) is a modular prosthetic component designed to attenuate impact forces, which unlike traditional pylons that are rigid, can compress to absorb, return, or dissipate energy. Previous studies found that walking with a SAP improved lower-limb prosthesis users’ comfort and residual limb pain. While longitudinal stiffness of a SAP has been shown to affect gait kinematics, kinetics, and work done by the entire lower limb, the energetic contributions from the prosthesis and the intact joints have not been examined. The purpose of this study was to determine the effects of SAP stiffness and walking speed on the mechanical work contributions of the prosthesis (i.e., all components distal to socket), knee, and hip in individuals with a transtibial amputation. METHODS: Twelve participants with unilateral transtibial amputation walked overground at their customary (1.22 ± 0.18 ms(−1)) and fast speeds (1.53 ± 0.29 ms(−1)) under four different levels of SAP stiffness. Power and mechanical work profiles of the leg joints and components distal to the socket were quantified. The effects of SAP stiffness and walking speed on positive and negative work were analyzed using two-factor (stiffness and speed) repeated-measure ANOVAs (α = 0.05). RESULTS: Faster walking significantly increased mechanical work from the SAP-integrated prosthesis (p < 0.001). Reducing SAP stiffness increased the magnitude of prosthesis negative work (energy absorption) during early stance (p = 0.045) by as much as 0.027 Jkg(−1), without affecting the positive work (energy return) during late stance (p = 0.159), suggesting a damping effect. This energy loss was partially offset by an increase in residual hip positive work (as much as 0.012 Jkg(−1)) during late stance (p = 0.045). Reducing SAP stiffness also reduced the magnitude of negative work on the contralateral sound limb during early stance by 11–17% (p = 0.001). CONCLUSIONS: Reducing SAP stiffness and faster walking amplified the prostheses damping effect, which redistributed the mechanical work, both in magnitude and timing, within the residual joints and sound limb. With its capacity to absorb and dissipate energy, future studies are warranted to determine whether SAPs can provide additional user benefit for locomotor tasks that require greater attenuation of impact forces (e.g., load carriage) or energy dissipation (e.g., downhill walking). SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12984-021-00939-8. BioMed Central 2021-09-21 /pmc/articles/PMC8456590/ /pubmed/34548080 http://dx.doi.org/10.1186/s12984-021-00939-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Maun, Jenny Anne Gard, Steven A. Major, Matthew J. Takahashi, Kota Z. Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
title | Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
title_full | Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
title_fullStr | Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
title_full_unstemmed | Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
title_short | Reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
title_sort | reducing stiffness of shock-absorbing pylon amplifies prosthesis energy loss and redistributes joint mechanical work during walking |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8456590/ https://www.ncbi.nlm.nih.gov/pubmed/34548080 http://dx.doi.org/10.1186/s12984-021-00939-8 |
work_keys_str_mv | AT maunjennyanne reducingstiffnessofshockabsorbingpylonamplifiesprosthesisenergylossandredistributesjointmechanicalworkduringwalking AT gardstevena reducingstiffnessofshockabsorbingpylonamplifiesprosthesisenergylossandredistributesjointmechanicalworkduringwalking AT majormatthewj reducingstiffnessofshockabsorbingpylonamplifiesprosthesisenergylossandredistributesjointmechanicalworkduringwalking AT takahashikotaz reducingstiffnessofshockabsorbingpylonamplifiesprosthesisenergylossandredistributesjointmechanicalworkduringwalking |