Cargando…

Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study

BACKGROUND: The locking plate is a useful treatment for lateral clavicle fractures, however, there are limits to the fragment size that can be fixed. The current study aimed to measure the screw angles of three locking plates for lateral clavicle fractures. In addition, to assess the number of screw...

Descripción completa

Detalles Bibliográficos
Autores principales: Abe, Shingo, Koizumi, Kota, Murase, Tsuyoshi, Kuriyama, Kohji
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8456609/
https://www.ncbi.nlm.nih.gov/pubmed/34548051
http://dx.doi.org/10.1186/s12891-021-04697-5
_version_ 1784570902166372352
author Abe, Shingo
Koizumi, Kota
Murase, Tsuyoshi
Kuriyama, Kohji
author_facet Abe, Shingo
Koizumi, Kota
Murase, Tsuyoshi
Kuriyama, Kohji
author_sort Abe, Shingo
collection PubMed
description BACKGROUND: The locking plate is a useful treatment for lateral clavicle fractures, however, there are limits to the fragment size that can be fixed. The current study aimed to measure the screw angles of three locking plates for lateral clavicle fractures. In addition, to assess the number of screws that can be inserted in different fragment sizes, to elucidate the size limits for locking plate fixation. METHODS: The following three locking plates were analyzed: the distal clavicle plate [Acumed, LLC, Oregon, the USA], the LCP clavicle plate lateral extension [Depuy Synthes, LLC, PA, the USA], and the HAI clavicle plate [HOMS Engineering, Inc., Nagano, Japan]. We measured the angles between the most medial and lateral locking screws in the coronal plane and between the most anterior and posterior locking screws in the sagittal plane. A computer simulation was used to position the plates as laterally as possible in ten normal three-dimensional clavicle models. Lateral fragment sizes of 10, 15, 20, 25, and 30 mm were simulated in the acromioclavicular joint, and the number of screws that could be inserted in the lateral fragment was assessed. Subsequently, the area covered by the locking screws on the inferior surface of the clavicle was measured. RESULTS: The distal clavicle plate had relatively large screw angles (20° in the coronal plane and 32° in the sagittal plane). The LCP clavicle lateral extension had a large angle (38°) in the sagittal plane. However, the maximum angle of the HAI clavicle plate was 13° in either plane. The distal clavicle plate allowed most screws to be inserted in each size of bone fragment. For all locking plates, all screws could be inserted in 25 mm fragments. The screws of distal clavicle plate covered the largest area on the inferior surface of the clavicle. CONCLUSIONS: Screw angles and the numbers of screws that could be inserted in the lateral fragment differed among products. Other augmented fixation procedures should be considered for fractures with fragment sizes < 25 mm that cannot be fixed with a sufficient number of screws. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04697-5.
format Online
Article
Text
id pubmed-8456609
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-84566092021-09-22 Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study Abe, Shingo Koizumi, Kota Murase, Tsuyoshi Kuriyama, Kohji BMC Musculoskelet Disord Research Article BACKGROUND: The locking plate is a useful treatment for lateral clavicle fractures, however, there are limits to the fragment size that can be fixed. The current study aimed to measure the screw angles of three locking plates for lateral clavicle fractures. In addition, to assess the number of screws that can be inserted in different fragment sizes, to elucidate the size limits for locking plate fixation. METHODS: The following three locking plates were analyzed: the distal clavicle plate [Acumed, LLC, Oregon, the USA], the LCP clavicle plate lateral extension [Depuy Synthes, LLC, PA, the USA], and the HAI clavicle plate [HOMS Engineering, Inc., Nagano, Japan]. We measured the angles between the most medial and lateral locking screws in the coronal plane and between the most anterior and posterior locking screws in the sagittal plane. A computer simulation was used to position the plates as laterally as possible in ten normal three-dimensional clavicle models. Lateral fragment sizes of 10, 15, 20, 25, and 30 mm were simulated in the acromioclavicular joint, and the number of screws that could be inserted in the lateral fragment was assessed. Subsequently, the area covered by the locking screws on the inferior surface of the clavicle was measured. RESULTS: The distal clavicle plate had relatively large screw angles (20° in the coronal plane and 32° in the sagittal plane). The LCP clavicle lateral extension had a large angle (38°) in the sagittal plane. However, the maximum angle of the HAI clavicle plate was 13° in either plane. The distal clavicle plate allowed most screws to be inserted in each size of bone fragment. For all locking plates, all screws could be inserted in 25 mm fragments. The screws of distal clavicle plate covered the largest area on the inferior surface of the clavicle. CONCLUSIONS: Screw angles and the numbers of screws that could be inserted in the lateral fragment differed among products. Other augmented fixation procedures should be considered for fractures with fragment sizes < 25 mm that cannot be fixed with a sufficient number of screws. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12891-021-04697-5. BioMed Central 2021-09-21 /pmc/articles/PMC8456609/ /pubmed/34548051 http://dx.doi.org/10.1186/s12891-021-04697-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Abe, Shingo
Koizumi, Kota
Murase, Tsuyoshi
Kuriyama, Kohji
Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
title Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
title_full Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
title_fullStr Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
title_full_unstemmed Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
title_short Comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
title_sort comparing the locking screw direction of three locking plates for lateral clavicle fractures: a simulation study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8456609/
https://www.ncbi.nlm.nih.gov/pubmed/34548051
http://dx.doi.org/10.1186/s12891-021-04697-5
work_keys_str_mv AT abeshingo comparingthelockingscrewdirectionofthreelockingplatesforlateralclaviclefracturesasimulationstudy
AT koizumikota comparingthelockingscrewdirectionofthreelockingplatesforlateralclaviclefracturesasimulationstudy
AT murasetsuyoshi comparingthelockingscrewdirectionofthreelockingplatesforlateralclaviclefracturesasimulationstudy
AT kuriyamakohji comparingthelockingscrewdirectionofthreelockingplatesforlateralclaviclefracturesasimulationstudy