Cargando…

Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity

Aim Hip fracture fixation surgeries are one of the most common surgeries that every trauma unit does regularly. Surgical training and expertise to fix these fractures properly are quite crucial for every orthopaedic surgeon. Therefore, orthopaedic training programmes all over the world consider sign...

Descripción completa

Detalles Bibliográficos
Autores principales: Bruce, Angus, De, Chiranjit, Golmohamad, Ramez, Habeebullah, Awais, Sikand, Manoj, Gulati, Aashish
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8457677/
https://www.ncbi.nlm.nih.gov/pubmed/34584803
http://dx.doi.org/10.7759/cureus.17393
_version_ 1784571151552348160
author Bruce, Angus
De, Chiranjit
Golmohamad, Ramez
Habeebullah, Awais
Sikand, Manoj
Gulati, Aashish
author_facet Bruce, Angus
De, Chiranjit
Golmohamad, Ramez
Habeebullah, Awais
Sikand, Manoj
Gulati, Aashish
author_sort Bruce, Angus
collection PubMed
description Aim Hip fracture fixation surgeries are one of the most common surgeries that every trauma unit does regularly. Surgical training and expertise to fix these fractures properly are quite crucial for every orthopaedic surgeon. Therefore, orthopaedic training programmes all over the world consider significant focus on this and teach trainee surgeons expectantly to manage these fractures independently. Surgical fixation of hip fractures often requires fluoroscopy assistance in the operating theatre with associated hazards from ionising radiation. Moreover, hip fractures can be sometimes quite complex and may require relatively more fluoroscopy usage even with the higher grade of the operating surgeons. Therefore, training need for hip fracture fixation surgery is imperative and there is also a need for intraoperative radiation safety. This study has tried to find a balance between intraoperative fluoroscopic radiation exposure, surgical training requirement, and hip fracture complexity. Methodology This single centre study has collected retrospective peri-operative data over a period of two years including hip fractures that required fluoroscopy-guided surgical fixation. Femoral head fractures, subtrochanteric fractures, diaphyseal fractures, and trochanteric fractures with associated pelvic fractures were excluded from the study. We collected data on demographic parameters, fracture complexity and grading (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association [AO/OTA] Classification), intraoperative ionising radiation exposure (centi-Gray/cm(2)), and grade of the operating surgeon in order to find any relation between these factors. Results Total 268 patients were included in the study with a mean age of 81.8 years (SD 9.3) comprising of 83 (31%) male patients and 185 (69%) female patients. The study population was further stratified into three groups depending upon the operating grade of the surgeon: ‘Junior Trainee’ (<five years of experience; 77 cases [29%]); ‘Senior Trainee’ (>five years of experience; 148 cases [55%]); and ‘Consultant’ (fully trained to practice independently; 43 cases [16%]). There was no statistically significant difference among these three sub-groups with regards to the age (p = 0.79), gender (p = 0.73), body mass index (p = 0.46), and fracture pattern (p = 0.96) of the patients. However, consultants tend to operate more on the higher American Society of Anesthesiologists (ASA) grade patients (p = 0.049) with more comorbidities. There was statistically significant higher fluoroscopic radiation exposure while junior trainee surgeons (p = 0.005) were operating and during the higher complex grade of hip fracture (p = <0.001) fixation. Conclusion In conclusion, the quantity of intra-operative radiation dose utilised in the surgical fixation of hip fractures is significantly associated with the grade and level of training of the operating surgeon and fracture complexity type. The results of this study emphasise and support the importance of comprehensive, supervised, and structured orthopaedic training for in-theatre radiation safety. It is recommended to have a safe balance between teaching, learning, and prevention of ionising radiation hazards in order to optimally achieve trainee’s professional development with successful patient outcomes.
format Online
Article
Text
id pubmed-8457677
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-84576772021-09-27 Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity Bruce, Angus De, Chiranjit Golmohamad, Ramez Habeebullah, Awais Sikand, Manoj Gulati, Aashish Cureus Orthopedics Aim Hip fracture fixation surgeries are one of the most common surgeries that every trauma unit does regularly. Surgical training and expertise to fix these fractures properly are quite crucial for every orthopaedic surgeon. Therefore, orthopaedic training programmes all over the world consider significant focus on this and teach trainee surgeons expectantly to manage these fractures independently. Surgical fixation of hip fractures often requires fluoroscopy assistance in the operating theatre with associated hazards from ionising radiation. Moreover, hip fractures can be sometimes quite complex and may require relatively more fluoroscopy usage even with the higher grade of the operating surgeons. Therefore, training need for hip fracture fixation surgery is imperative and there is also a need for intraoperative radiation safety. This study has tried to find a balance between intraoperative fluoroscopic radiation exposure, surgical training requirement, and hip fracture complexity. Methodology This single centre study has collected retrospective peri-operative data over a period of two years including hip fractures that required fluoroscopy-guided surgical fixation. Femoral head fractures, subtrochanteric fractures, diaphyseal fractures, and trochanteric fractures with associated pelvic fractures were excluded from the study. We collected data on demographic parameters, fracture complexity and grading (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association [AO/OTA] Classification), intraoperative ionising radiation exposure (centi-Gray/cm(2)), and grade of the operating surgeon in order to find any relation between these factors. Results Total 268 patients were included in the study with a mean age of 81.8 years (SD 9.3) comprising of 83 (31%) male patients and 185 (69%) female patients. The study population was further stratified into three groups depending upon the operating grade of the surgeon: ‘Junior Trainee’ (<five years of experience; 77 cases [29%]); ‘Senior Trainee’ (>five years of experience; 148 cases [55%]); and ‘Consultant’ (fully trained to practice independently; 43 cases [16%]). There was no statistically significant difference among these three sub-groups with regards to the age (p = 0.79), gender (p = 0.73), body mass index (p = 0.46), and fracture pattern (p = 0.96) of the patients. However, consultants tend to operate more on the higher American Society of Anesthesiologists (ASA) grade patients (p = 0.049) with more comorbidities. There was statistically significant higher fluoroscopic radiation exposure while junior trainee surgeons (p = 0.005) were operating and during the higher complex grade of hip fracture (p = <0.001) fixation. Conclusion In conclusion, the quantity of intra-operative radiation dose utilised in the surgical fixation of hip fractures is significantly associated with the grade and level of training of the operating surgeon and fracture complexity type. The results of this study emphasise and support the importance of comprehensive, supervised, and structured orthopaedic training for in-theatre radiation safety. It is recommended to have a safe balance between teaching, learning, and prevention of ionising radiation hazards in order to optimally achieve trainee’s professional development with successful patient outcomes. Cureus 2021-08-23 /pmc/articles/PMC8457677/ /pubmed/34584803 http://dx.doi.org/10.7759/cureus.17393 Text en Copyright © 2021, Bruce et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Bruce, Angus
De, Chiranjit
Golmohamad, Ramez
Habeebullah, Awais
Sikand, Manoj
Gulati, Aashish
Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
title Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
title_full Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
title_fullStr Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
title_full_unstemmed Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
title_short Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity
title_sort intraoperative fluoroscopic radiation exposure during hip fracture fixation: a study combining surgical experience and fracture complexity
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8457677/
https://www.ncbi.nlm.nih.gov/pubmed/34584803
http://dx.doi.org/10.7759/cureus.17393
work_keys_str_mv AT bruceangus intraoperativefluoroscopicradiationexposureduringhipfracturefixationastudycombiningsurgicalexperienceandfracturecomplexity
AT dechiranjit intraoperativefluoroscopicradiationexposureduringhipfracturefixationastudycombiningsurgicalexperienceandfracturecomplexity
AT golmohamadramez intraoperativefluoroscopicradiationexposureduringhipfracturefixationastudycombiningsurgicalexperienceandfracturecomplexity
AT habeebullahawais intraoperativefluoroscopicradiationexposureduringhipfracturefixationastudycombiningsurgicalexperienceandfracturecomplexity
AT sikandmanoj intraoperativefluoroscopicradiationexposureduringhipfracturefixationastudycombiningsurgicalexperienceandfracturecomplexity
AT gulatiaashish intraoperativefluoroscopicradiationexposureduringhipfracturefixationastudycombiningsurgicalexperienceandfracturecomplexity