Cargando…
Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen
BACKGROUND: Sensor-based monitoring allows continuous observations of patient mobilization after proximal femoral fractures. A wrist-worn motion tracker allows long-term observation that is low in interruption and constraints for subjects. OBJECTIVE: Description of steps development after hip fractu...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Medizin
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8458168/ https://www.ncbi.nlm.nih.gov/pubmed/33620547 http://dx.doi.org/10.1007/s00391-021-01861-3 |
_version_ | 1784571254913630208 |
---|---|
author | Altenbuchner, Amelie Haug, Sonja Weber, Karsten |
author_facet | Altenbuchner, Amelie Haug, Sonja Weber, Karsten |
author_sort | Altenbuchner, Amelie |
collection | PubMed |
description | BACKGROUND: Sensor-based monitoring allows continuous observations of patient mobilization after proximal femoral fractures. A wrist-worn motion tracker allows long-term observation that is low in interruption and constraints for subjects. OBJECTIVE: Description of steps development after hip fracture surgery on a specialized geriatric trauma ward and beyond. MATERIAL AND METHODS: In the explorative long-term field research study, an applicable motion tracker observed steps per day of 20 patients (80% female, mean age 85.2 years ± 7.86 years) for 10 weeks. Weekly mean values (days 1–7, 8–14 etc.) of steps per day formed the database for descriptive analysis (mean, SD, min, max, median). RESULTS: During observation weeks (ow) a positive development of steps took place. A mean increase factor of 1.285 (±0.351) occurred from ow 1 (M = 353.57 ± 310.15) to ow 10 (M = 2482.07 ± 1374.12). The highest increase by a factor of 1.8 could be reported from ow 2 (M = 556.27 ± 478.11) to ow 3 (M = 1024.86 ± 921.24) as well as from ow 6 (M = 1268.21 ± 880.47) to 7 (M = 2367.14 ± 1680.08). A slight decrease of steps occurred from ow 4 (M = 1208.27 ± 1210.45) to ow 5 (0.99-fold) and from ow 9 (M = 2689.98 ± 2339.71) to 10 (0.92-fold). High ranges and standard deviations in relation to the mean occurred constantly. The presence of several step development groups could be presumed. CONCLUSION: Motion tracker and the variable steps per day can represent the ability to walk within an everyday environment, with a possible underestimation of < 10%. Differences regarding observation lengths and disruptions occurred. Cluster analysis should detect group attributes of different courses of development in subsequent studies. |
format | Online Article Text |
id | pubmed-8458168 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Springer Medizin |
record_format | MEDLINE/PubMed |
spelling | pubmed-84581682021-10-07 Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen Altenbuchner, Amelie Haug, Sonja Weber, Karsten Z Gerontol Geriatr Originalien BACKGROUND: Sensor-based monitoring allows continuous observations of patient mobilization after proximal femoral fractures. A wrist-worn motion tracker allows long-term observation that is low in interruption and constraints for subjects. OBJECTIVE: Description of steps development after hip fracture surgery on a specialized geriatric trauma ward and beyond. MATERIAL AND METHODS: In the explorative long-term field research study, an applicable motion tracker observed steps per day of 20 patients (80% female, mean age 85.2 years ± 7.86 years) for 10 weeks. Weekly mean values (days 1–7, 8–14 etc.) of steps per day formed the database for descriptive analysis (mean, SD, min, max, median). RESULTS: During observation weeks (ow) a positive development of steps took place. A mean increase factor of 1.285 (±0.351) occurred from ow 1 (M = 353.57 ± 310.15) to ow 10 (M = 2482.07 ± 1374.12). The highest increase by a factor of 1.8 could be reported from ow 2 (M = 556.27 ± 478.11) to ow 3 (M = 1024.86 ± 921.24) as well as from ow 6 (M = 1268.21 ± 880.47) to 7 (M = 2367.14 ± 1680.08). A slight decrease of steps occurred from ow 4 (M = 1208.27 ± 1210.45) to ow 5 (0.99-fold) and from ow 9 (M = 2689.98 ± 2339.71) to 10 (0.92-fold). High ranges and standard deviations in relation to the mean occurred constantly. The presence of several step development groups could be presumed. CONCLUSION: Motion tracker and the variable steps per day can represent the ability to walk within an everyday environment, with a possible underestimation of < 10%. Differences regarding observation lengths and disruptions occurred. Cluster analysis should detect group attributes of different courses of development in subsequent studies. Springer Medizin 2021-02-23 2021 /pmc/articles/PMC8458168/ /pubmed/33620547 http://dx.doi.org/10.1007/s00391-021-01861-3 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access Dieser Artikel wird unter der Creative Commons Namensnennung 4.0 International Lizenz veröffentlicht, welche die Nutzung, Vervielfältigung, Bearbeitung, Verbreitung und Wiedergabe in jeglichem Medium und Format erlaubt, sofern Sie den/die ursprünglichen Autor(en) und die Quelle ordnungsgemäß nennen, einen Link zur Creative Commons Lizenz beifügen und angeben, ob Änderungen vorgenommen wurden. Die in diesem Artikel enthaltenen Bilder und sonstiges Drittmaterial unterliegen ebenfalls der genannten Creative Commons Lizenz, sofern sich aus der Abbildungslegende nichts anderes ergibt. Sofern das betreffende Material nicht unter der genannten Creative Commons Lizenz steht und die betreffende Handlung nicht nach gesetzlichen Vorschriften erlaubt ist, ist für die oben aufgeführten Weiterverwendungen des Materials die Einwilligung des jeweiligen Rechteinhabers einzuholen. Weitere Details zur Lizenz entnehmen Sie bitte der Lizenzinformation auf http://creativecommons.org/licenses/by/4.0/deed.de (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Originalien Altenbuchner, Amelie Haug, Sonja Weber, Karsten Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen |
title | Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen |
title_full | Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen |
title_fullStr | Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen |
title_full_unstemmed | Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen |
title_short | Die ersten Schritte nach einer hüftnahen Fraktur: Sensorbasierte Bewegungsexploration bei geriatrischen Traumapatient/-innen |
title_sort | die ersten schritte nach einer hüftnahen fraktur: sensorbasierte bewegungsexploration bei geriatrischen traumapatient/-innen |
topic | Originalien |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8458168/ https://www.ncbi.nlm.nih.gov/pubmed/33620547 http://dx.doi.org/10.1007/s00391-021-01861-3 |
work_keys_str_mv | AT altenbuchneramelie dieerstenschrittenacheinerhuftnahenfraktursensorbasiertebewegungsexplorationbeigeriatrischentraumapatientinnen AT haugsonja dieerstenschrittenacheinerhuftnahenfraktursensorbasiertebewegungsexplorationbeigeriatrischentraumapatientinnen AT weberkarsten dieerstenschrittenacheinerhuftnahenfraktursensorbasiertebewegungsexplorationbeigeriatrischentraumapatientinnen |