Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis

An 80-year-old Japanese man presented with decreased vision in his right eye (OD) after every hemodialysis (HD) session beginning several months previously. His local ophthalmologist prescribed antiglaucoma medications because of high intraocular pressure (IOP) (38 mm Hg) OD 4 months previously; wit...

Descripción completa

Detalles Bibliográficos
Autores principales: Mochiji, Mihoko, Tsutsui, Aika, Manabe, Kaoru, Tanito, Masaki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: S. Karger AG 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8460952/
https://www.ncbi.nlm.nih.gov/pubmed/34720974
http://dx.doi.org/10.1159/000513957
_version_ 1784571872867778560
author Mochiji, Mihoko
Tsutsui, Aika
Manabe, Kaoru
Tanito, Masaki
author_facet Mochiji, Mihoko
Tsutsui, Aika
Manabe, Kaoru
Tanito, Masaki
author_sort Mochiji, Mihoko
collection PubMed
description An 80-year-old Japanese man presented with decreased vision in his right eye (OD) after every hemodialysis (HD) session beginning several months previously. His local ophthalmologist prescribed antiglaucoma medications because of high intraocular pressure (IOP) (38 mm Hg) OD 4 months previously; with treatment, the IOP fluctuated between 6 and 34 mm Hg OD. When hospitalized, the IOP was measured, and the anterior chamber was observed by anterior-segment optical coherence tomography (AS-OCT) before and after HD. Before HD, the IOP levels were 7 mm Hg OD and 8 mm Hg in the left eye (OS). AS-OCT showed marked anterior iris bowing due to circumferential posterior synechia OD. The scan showed irido-trabecular contact (ITC) in the nasal angle and not the temporal angle OD. Immediately after HD, the IOP levels were 28 mm Hg OD and 12 mm Hg OS; AS-OCT showed ITC in the nasal and temporal angles OD. Since the iris bombe and HD-induced increase in the ITC were expected to have caused the IOP spike and blurred vision, posterior synechialysis and goniosynechialysis were performed OD. Postoperatively, the iris plane flattened; no IOP spike was recorded, and the blurred vision after HD resolved. At 22 months postoperatively, the IOP was 7 mm Hg in both eyes (OU). No deterioration of visual acuity and visual field was recorded during the follow-up period OU. IOP spikes can occur during and after HD because of transient anterior chamber angle obstruction in cases with narrow angles. AS-OCT is useful for detecting minor morphologic changes in the anterior chamber angle during HD.
format Online
Article
Text
id pubmed-8460952
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher S. Karger AG
record_format MEDLINE/PubMed
spelling pubmed-84609522021-10-28 Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis Mochiji, Mihoko Tsutsui, Aika Manabe, Kaoru Tanito, Masaki Case Rep Ophthalmol Case Report An 80-year-old Japanese man presented with decreased vision in his right eye (OD) after every hemodialysis (HD) session beginning several months previously. His local ophthalmologist prescribed antiglaucoma medications because of high intraocular pressure (IOP) (38 mm Hg) OD 4 months previously; with treatment, the IOP fluctuated between 6 and 34 mm Hg OD. When hospitalized, the IOP was measured, and the anterior chamber was observed by anterior-segment optical coherence tomography (AS-OCT) before and after HD. Before HD, the IOP levels were 7 mm Hg OD and 8 mm Hg in the left eye (OS). AS-OCT showed marked anterior iris bowing due to circumferential posterior synechia OD. The scan showed irido-trabecular contact (ITC) in the nasal angle and not the temporal angle OD. Immediately after HD, the IOP levels were 28 mm Hg OD and 12 mm Hg OS; AS-OCT showed ITC in the nasal and temporal angles OD. Since the iris bombe and HD-induced increase in the ITC were expected to have caused the IOP spike and blurred vision, posterior synechialysis and goniosynechialysis were performed OD. Postoperatively, the iris plane flattened; no IOP spike was recorded, and the blurred vision after HD resolved. At 22 months postoperatively, the IOP was 7 mm Hg in both eyes (OU). No deterioration of visual acuity and visual field was recorded during the follow-up period OU. IOP spikes can occur during and after HD because of transient anterior chamber angle obstruction in cases with narrow angles. AS-OCT is useful for detecting minor morphologic changes in the anterior chamber angle during HD. S. Karger AG 2021-09-13 /pmc/articles/PMC8460952/ /pubmed/34720974 http://dx.doi.org/10.1159/000513957 Text en Copyright © 2021 by S. Karger AG, Basel https://creativecommons.org/licenses/by-nc/4.0/This article is licensed under the Creative Commons Attribution-NonCommercial-4.0 International License (CC BY-NC) (http://www.karger.com/Services/OpenAccessLicense). Usage and distribution for commercial purposes requires written permission.
spellingShingle Case Report
Mochiji, Mihoko
Tsutsui, Aika
Manabe, Kaoru
Tanito, Masaki
Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis
title Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis
title_full Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis
title_fullStr Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis
title_full_unstemmed Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis
title_short Transient Angle Obstruction Detected by Anterior-Segment Optical Coherence Tomography and Intraocular Pressure Elevation after Hemodialysis
title_sort transient angle obstruction detected by anterior-segment optical coherence tomography and intraocular pressure elevation after hemodialysis
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8460952/
https://www.ncbi.nlm.nih.gov/pubmed/34720974
http://dx.doi.org/10.1159/000513957
work_keys_str_mv AT mochijimihoko transientangleobstructiondetectedbyanteriorsegmentopticalcoherencetomographyandintraocularpressureelevationafterhemodialysis
AT tsutsuiaika transientangleobstructiondetectedbyanteriorsegmentopticalcoherencetomographyandintraocularpressureelevationafterhemodialysis
AT manabekaoru transientangleobstructiondetectedbyanteriorsegmentopticalcoherencetomographyandintraocularpressureelevationafterhemodialysis
AT tanitomasaki transientangleobstructiondetectedbyanteriorsegmentopticalcoherencetomographyandintraocularpressureelevationafterhemodialysis