Cargando…
Effect of simple interventions on the performance of a miniature MFC fed with fresh urine
The aim of the present study is to enhance the performance of a microbial fuel cell (MFC) design by making simple interventions. Specifically, terracotta “t” and mullite “m” ceramics are tested as membranes while carbon veil and carbon cloth are used as electrodes. In the case of “m” cylinders diffe...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Pergamon Press
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8461078/ https://www.ncbi.nlm.nih.gov/pubmed/34594062 http://dx.doi.org/10.1016/j.ijhydene.2021.07.171 |
Sumario: | The aim of the present study is to enhance the performance of a microbial fuel cell (MFC) design by making simple interventions. Specifically, terracotta “t” and mullite “m” ceramics are tested as membranes while carbon veil and carbon cloth are used as electrodes. In the case of “m” cylinders different dimensions are examined (m: ID 30 mm x height 11.5 mm; sm: ID 18 mm x height 18 mm). The units operated continuously with urine as the feedstock. The best performing is the sm type (60–100 μW), followed by the t type (40–80 μW) and the m type (20–40 μW). Polarisation experiments indicated that activated carbon on the anode enhances the power output (t: 423 μW, sm: 288 μW). Similarly, the increase of the surface area and the addition of stainless steel mesh on the cathode improves the power performance for the “sm” and the “t” units. Furthermore, it is shown that the design with the smaller internal diameter, performs better and is more stable through time. |
---|