Cargando…

Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition

Background and Purpose: Robot-assisted cochlear implantation has recently been implemented in clinical practice; however, its effect on hearing outcomes is unknown. The aim of this preliminary study was to evaluate hearing performance 1 year post-implantation whether the electrode array was inserted...

Descripción completa

Detalles Bibliográficos
Autores principales: Torres, Renato, Daoudi, Hannah, Lahlou, Ghizlene, Sterkers, Olivier, Ferrary, Evelyne, Mosnier, Isabelle, Nguyen, Yann
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8461256/
https://www.ncbi.nlm.nih.gov/pubmed/34568420
http://dx.doi.org/10.3389/fsurg.2021.729736
_version_ 1784571937738981376
author Torres, Renato
Daoudi, Hannah
Lahlou, Ghizlene
Sterkers, Olivier
Ferrary, Evelyne
Mosnier, Isabelle
Nguyen, Yann
author_facet Torres, Renato
Daoudi, Hannah
Lahlou, Ghizlene
Sterkers, Olivier
Ferrary, Evelyne
Mosnier, Isabelle
Nguyen, Yann
author_sort Torres, Renato
collection PubMed
description Background and Purpose: Robot-assisted cochlear implantation has recently been implemented in clinical practice; however, its effect on hearing outcomes is unknown. The aim of this preliminary study was to evaluate hearing performance 1 year post-implantation whether the electrode array was inserted manually or assisted by a robot. Methods: Forty-two profoundly deaf adults were implanted either manually (n = 21) or assisted by a robot (RobOtol®, Collin, Bagneux, France) with three different electrode array types. Participants were paired by age, and electrode array type. The scalar position of the electrode array in the cochlea was assessed by 3D reconstruction from the pre- and post-implantation computed tomography. Pure-tone audiometry and speech perception in silence (percentage of disyllabic words at 60 dB) were tested on the implanted ear 1 year post-implantation in free-field conditions. The pure-tone average was calculated at 250–500–750 Hz, 500–1,000–2,000–3,000 Hz, and 3,000–4,000–8,000 Hz for low, mid, and high frequencies, respectively. Results: One year after cochlear implantation, restoration of the high-frequency thresholds was associated with better speech perception in silence, but not with low or mid frequencies (p < 0.0001; Adjusted R(2) = 0.64, polynomial non-linear regression). Although array translocation was similar using either technique, the number of translocated electrodes was lower when the electrode arrays had been inserted with the assistance of the robot compared with manual insertion (p = 0.018; Fisher's exact test). Conclusion: The restoration of high-frequency thresholds (3,000–4,000–8,000 Hz) by cochlear implantation was associated with good speech perception in silence. The numbers of translocated electrodes were reduced after a robot-assisted insertion.
format Online
Article
Text
id pubmed-8461256
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-84612562021-09-25 Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition Torres, Renato Daoudi, Hannah Lahlou, Ghizlene Sterkers, Olivier Ferrary, Evelyne Mosnier, Isabelle Nguyen, Yann Front Surg Surgery Background and Purpose: Robot-assisted cochlear implantation has recently been implemented in clinical practice; however, its effect on hearing outcomes is unknown. The aim of this preliminary study was to evaluate hearing performance 1 year post-implantation whether the electrode array was inserted manually or assisted by a robot. Methods: Forty-two profoundly deaf adults were implanted either manually (n = 21) or assisted by a robot (RobOtol®, Collin, Bagneux, France) with three different electrode array types. Participants were paired by age, and electrode array type. The scalar position of the electrode array in the cochlea was assessed by 3D reconstruction from the pre- and post-implantation computed tomography. Pure-tone audiometry and speech perception in silence (percentage of disyllabic words at 60 dB) were tested on the implanted ear 1 year post-implantation in free-field conditions. The pure-tone average was calculated at 250–500–750 Hz, 500–1,000–2,000–3,000 Hz, and 3,000–4,000–8,000 Hz for low, mid, and high frequencies, respectively. Results: One year after cochlear implantation, restoration of the high-frequency thresholds was associated with better speech perception in silence, but not with low or mid frequencies (p < 0.0001; Adjusted R(2) = 0.64, polynomial non-linear regression). Although array translocation was similar using either technique, the number of translocated electrodes was lower when the electrode arrays had been inserted with the assistance of the robot compared with manual insertion (p = 0.018; Fisher's exact test). Conclusion: The restoration of high-frequency thresholds (3,000–4,000–8,000 Hz) by cochlear implantation was associated with good speech perception in silence. The numbers of translocated electrodes were reduced after a robot-assisted insertion. Frontiers Media S.A. 2021-09-10 /pmc/articles/PMC8461256/ /pubmed/34568420 http://dx.doi.org/10.3389/fsurg.2021.729736 Text en Copyright © 2021 Torres, Daoudi, Lahlou, Sterkers, Ferrary, Mosnier and Nguyen. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Torres, Renato
Daoudi, Hannah
Lahlou, Ghizlene
Sterkers, Olivier
Ferrary, Evelyne
Mosnier, Isabelle
Nguyen, Yann
Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition
title Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition
title_full Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition
title_fullStr Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition
title_full_unstemmed Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition
title_short Restoration of High Frequency Auditory Perception After Robot-Assisted or Manual Cochlear Implantation in Profoundly Deaf Adults Improves Speech Recognition
title_sort restoration of high frequency auditory perception after robot-assisted or manual cochlear implantation in profoundly deaf adults improves speech recognition
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8461256/
https://www.ncbi.nlm.nih.gov/pubmed/34568420
http://dx.doi.org/10.3389/fsurg.2021.729736
work_keys_str_mv AT torresrenato restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition
AT daoudihannah restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition
AT lahloughizlene restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition
AT sterkersolivier restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition
AT ferraryevelyne restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition
AT mosnierisabelle restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition
AT nguyenyann restorationofhighfrequencyauditoryperceptionafterrobotassistedormanualcochlearimplantationinprofoundlydeafadultsimprovesspeechrecognition