Cargando…

Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts

AIMS: Recently, a new defibrillation modality using nanosecond pulses was shown to be effective at much lower energies than conventional 10 millisecond monophasic shocks in ex vivo experiments. Here we compare the safety factors of 300 nanosecond and 10 millisecond shocks to assess the safety of nan...

Descripción completa

Detalles Bibliográficos
Autores principales: Neuber, Johanna U., Pakhomov, Andrei G., Zemlin, Christian W.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8462679/
https://www.ncbi.nlm.nih.gov/pubmed/34559811
http://dx.doi.org/10.1371/journal.pone.0257287
_version_ 1784572245784395776
author Neuber, Johanna U.
Pakhomov, Andrei G.
Zemlin, Christian W.
author_facet Neuber, Johanna U.
Pakhomov, Andrei G.
Zemlin, Christian W.
author_sort Neuber, Johanna U.
collection PubMed
description AIMS: Recently, a new defibrillation modality using nanosecond pulses was shown to be effective at much lower energies than conventional 10 millisecond monophasic shocks in ex vivo experiments. Here we compare the safety factors of 300 nanosecond and 10 millisecond shocks to assess the safety of nanosecond defibrillation. METHODS AND RESULTS: The safety factor, i.e. the ratio of median effective doses (ED50) for electroporative damage and defibrillation, was assessed for nanosecond and conventional (millisecond) defibrillation shocks in Langendorff-perfused New Zealand white rabbit hearts. In order to allow for multiple shock applications in a single heart, a pair of needle electrodes was used to apply shocks of varying voltage. Propidium iodide (PI) staining at the surface of the heart showed that nanosecond shocks had a slightly lower safety factor (6.50) than millisecond shocks (8.69), p = 0.02; while PI staining cross-sections in the electrode plane showed no significant difference (5.38 for 300 ns shocks and 6.29 for 10 ms shocks, p = 0.22). CONCLUSIONS: In Langendorff-perfused rabbit hearts, nanosecond defibrillation has a similar safety factor as millisecond defibrillation, between 5 and 9, suggesting that nanosecond defibrillation can be performed safely.
format Online
Article
Text
id pubmed-8462679
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-84626792021-09-25 Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts Neuber, Johanna U. Pakhomov, Andrei G. Zemlin, Christian W. PLoS One Research Article AIMS: Recently, a new defibrillation modality using nanosecond pulses was shown to be effective at much lower energies than conventional 10 millisecond monophasic shocks in ex vivo experiments. Here we compare the safety factors of 300 nanosecond and 10 millisecond shocks to assess the safety of nanosecond defibrillation. METHODS AND RESULTS: The safety factor, i.e. the ratio of median effective doses (ED50) for electroporative damage and defibrillation, was assessed for nanosecond and conventional (millisecond) defibrillation shocks in Langendorff-perfused New Zealand white rabbit hearts. In order to allow for multiple shock applications in a single heart, a pair of needle electrodes was used to apply shocks of varying voltage. Propidium iodide (PI) staining at the surface of the heart showed that nanosecond shocks had a slightly lower safety factor (6.50) than millisecond shocks (8.69), p = 0.02; while PI staining cross-sections in the electrode plane showed no significant difference (5.38 for 300 ns shocks and 6.29 for 10 ms shocks, p = 0.22). CONCLUSIONS: In Langendorff-perfused rabbit hearts, nanosecond defibrillation has a similar safety factor as millisecond defibrillation, between 5 and 9, suggesting that nanosecond defibrillation can be performed safely. Public Library of Science 2021-09-24 /pmc/articles/PMC8462679/ /pubmed/34559811 http://dx.doi.org/10.1371/journal.pone.0257287 Text en © 2021 Neuber et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Neuber, Johanna U.
Pakhomov, Andrei G.
Zemlin, Christian W.
Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts
title Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts
title_full Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts
title_fullStr Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts
title_full_unstemmed Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts
title_short Electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in Langendorff-perfused rabbit hearts
title_sort electroporation safety factor of 300 nanosecond and 10 millisecond defibrillation in langendorff-perfused rabbit hearts
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8462679/
https://www.ncbi.nlm.nih.gov/pubmed/34559811
http://dx.doi.org/10.1371/journal.pone.0257287
work_keys_str_mv AT neuberjohannau electroporationsafetyfactorof300nanosecondand10milliseconddefibrillationinlangendorffperfusedrabbithearts
AT pakhomovandreig electroporationsafetyfactorof300nanosecondand10milliseconddefibrillationinlangendorffperfusedrabbithearts
AT zemlinchristianw electroporationsafetyfactorof300nanosecondand10milliseconddefibrillationinlangendorffperfusedrabbithearts