Cargando…
Interventions to mitigate indoor air pollution: A cost-benefit analysis
Globally, around three billion people depend upon solid fuels such as firewood, dry animal dung, crop residues, or coal, and use traditional stoves for cooking and heating purposes. This solid fuel combustion causes indoor air pollution (IAP) and severely impairs health and the environment, especial...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8462720/ https://www.ncbi.nlm.nih.gov/pubmed/34559814 http://dx.doi.org/10.1371/journal.pone.0257543 |
_version_ | 1784572256510279680 |
---|---|
author | Irfan, Muhammad Cameron, Michael P. Hassan, Gazi |
author_facet | Irfan, Muhammad Cameron, Michael P. Hassan, Gazi |
author_sort | Irfan, Muhammad |
collection | PubMed |
description | Globally, around three billion people depend upon solid fuels such as firewood, dry animal dung, crop residues, or coal, and use traditional stoves for cooking and heating purposes. This solid fuel combustion causes indoor air pollution (IAP) and severely impairs health and the environment, especially in developing countries like Pakistan. A number of alternative household energy strategies can be adopted to mitigate IAP, such as using liquefied petroleum gas (LPG), natural gas, biogas, electric stoves, or improved cook stoves (ICS). In this study, we estimate the benefit-cost ratios and net present value of these interventions over a ten-year period in Pakistan. Annual costs include both fixed and operating costs, whereas benefits cover health, productivity gains, time savings, and fuel savings. We find that LPG has the highest benefit-cost ratio, followed by natural gas, while ICS has the lowest benefit-cost ratio. Electric stoves and biogas have moderate benefit-cost ratios that nevertheless exceed one. To maximize the return on cleaner burning technology, the government of Pakistan should consider encouraging the adoption of LPG, piped natural gas, and electric stoves as means to reduce IAP and adopt clean technologies. |
format | Online Article Text |
id | pubmed-8462720 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-84627202021-09-25 Interventions to mitigate indoor air pollution: A cost-benefit analysis Irfan, Muhammad Cameron, Michael P. Hassan, Gazi PLoS One Research Article Globally, around three billion people depend upon solid fuels such as firewood, dry animal dung, crop residues, or coal, and use traditional stoves for cooking and heating purposes. This solid fuel combustion causes indoor air pollution (IAP) and severely impairs health and the environment, especially in developing countries like Pakistan. A number of alternative household energy strategies can be adopted to mitigate IAP, such as using liquefied petroleum gas (LPG), natural gas, biogas, electric stoves, or improved cook stoves (ICS). In this study, we estimate the benefit-cost ratios and net present value of these interventions over a ten-year period in Pakistan. Annual costs include both fixed and operating costs, whereas benefits cover health, productivity gains, time savings, and fuel savings. We find that LPG has the highest benefit-cost ratio, followed by natural gas, while ICS has the lowest benefit-cost ratio. Electric stoves and biogas have moderate benefit-cost ratios that nevertheless exceed one. To maximize the return on cleaner burning technology, the government of Pakistan should consider encouraging the adoption of LPG, piped natural gas, and electric stoves as means to reduce IAP and adopt clean technologies. Public Library of Science 2021-09-24 /pmc/articles/PMC8462720/ /pubmed/34559814 http://dx.doi.org/10.1371/journal.pone.0257543 Text en © 2021 Irfan et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Irfan, Muhammad Cameron, Michael P. Hassan, Gazi Interventions to mitigate indoor air pollution: A cost-benefit analysis |
title | Interventions to mitigate indoor air pollution: A cost-benefit analysis |
title_full | Interventions to mitigate indoor air pollution: A cost-benefit analysis |
title_fullStr | Interventions to mitigate indoor air pollution: A cost-benefit analysis |
title_full_unstemmed | Interventions to mitigate indoor air pollution: A cost-benefit analysis |
title_short | Interventions to mitigate indoor air pollution: A cost-benefit analysis |
title_sort | interventions to mitigate indoor air pollution: a cost-benefit analysis |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8462720/ https://www.ncbi.nlm.nih.gov/pubmed/34559814 http://dx.doi.org/10.1371/journal.pone.0257543 |
work_keys_str_mv | AT irfanmuhammad interventionstomitigateindoorairpollutionacostbenefitanalysis AT cameronmichaelp interventionstomitigateindoorairpollutionacostbenefitanalysis AT hassangazi interventionstomitigateindoorairpollutionacostbenefitanalysis |