Cargando…

Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept

METHODS: The influences of methanol proportion, flow rate, column temperature, and injection volume in the mobile phase on the chromatographic resolution of chromatographic peak of euphorbia factor L1 were experimentally studied via Plackett–Burman design, and the key analysis parameters were screen...

Descripción completa

Detalles Bibliográficos
Autores principales: Xuehua, Feng, Guangjiao, Zhou, Ali, Tao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8463240/
https://www.ncbi.nlm.nih.gov/pubmed/34567821
http://dx.doi.org/10.1155/2021/4311934
_version_ 1784572359288553472
author Xuehua, Feng
Guangjiao, Zhou
Ali, Tao
author_facet Xuehua, Feng
Guangjiao, Zhou
Ali, Tao
author_sort Xuehua, Feng
collection PubMed
description METHODS: The influences of methanol proportion, flow rate, column temperature, and injection volume in the mobile phase on the chromatographic resolution of chromatographic peak of euphorbia factor L1 were experimentally studied via Plackett–Burman design, and the key analysis parameters were screened out; the key analysis parameters were optimized through the central composite design, and the chromatographic analysis conditions were established. Euphorbia factor L1 was taken as the internal reference to construct the relative correction factors for L3 and L4 relative to L1, and their contents were calculated, thus realizing the QAMS. Meanwhile, the euphorbia factor L3 and euphorbia factor L4 were determined using the external standard method, and the differences of values measured by the external standard method from the values predicted by the QAMS method were compared, in an effort to verify the accuracy and feasibility of the QAMS method. RESULTS: The methanol proportion and column temperature in the mobile phase were the key analysis parameters (P < 0.05), and the chromatographic conditions were determined as follows. The methanol/water ratio, column temperature, detection wavelength, flow rate, and injection volume were 60 : 40, 30°C, 275 nm, 1.0 mL/min, and 10 μL, respectively. A total of 20 batches of samples were determined by the QAMS method and external standard method; the relative standard deviations (RSDs) of L3 and L4 determination results were less than 2.0%, without any significant difference. CONCLUSION: The QbD-based QAMS method can be used to determine the contents of euphorbia factor L3 and euphorbia factor L4 in Euphorbia lathyris L., and it is accurate and feasible.
format Online
Article
Text
id pubmed-8463240
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-84632402021-09-25 Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept Xuehua, Feng Guangjiao, Zhou Ali, Tao J Anal Methods Chem Research Article METHODS: The influences of methanol proportion, flow rate, column temperature, and injection volume in the mobile phase on the chromatographic resolution of chromatographic peak of euphorbia factor L1 were experimentally studied via Plackett–Burman design, and the key analysis parameters were screened out; the key analysis parameters were optimized through the central composite design, and the chromatographic analysis conditions were established. Euphorbia factor L1 was taken as the internal reference to construct the relative correction factors for L3 and L4 relative to L1, and their contents were calculated, thus realizing the QAMS. Meanwhile, the euphorbia factor L3 and euphorbia factor L4 were determined using the external standard method, and the differences of values measured by the external standard method from the values predicted by the QAMS method were compared, in an effort to verify the accuracy and feasibility of the QAMS method. RESULTS: The methanol proportion and column temperature in the mobile phase were the key analysis parameters (P < 0.05), and the chromatographic conditions were determined as follows. The methanol/water ratio, column temperature, detection wavelength, flow rate, and injection volume were 60 : 40, 30°C, 275 nm, 1.0 mL/min, and 10 μL, respectively. A total of 20 batches of samples were determined by the QAMS method and external standard method; the relative standard deviations (RSDs) of L3 and L4 determination results were less than 2.0%, without any significant difference. CONCLUSION: The QbD-based QAMS method can be used to determine the contents of euphorbia factor L3 and euphorbia factor L4 in Euphorbia lathyris L., and it is accurate and feasible. Hindawi 2021-09-17 /pmc/articles/PMC8463240/ /pubmed/34567821 http://dx.doi.org/10.1155/2021/4311934 Text en Copyright © 2021 Feng Xuehua et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xuehua, Feng
Guangjiao, Zhou
Ali, Tao
Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept
title Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept
title_full Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept
title_fullStr Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept
title_full_unstemmed Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept
title_short Establishment of the Quantitative Analysis of Multiindex in Euphorbia lathyris by the Single Marker Method for Euphorbia lathyris Based on the Quality by Design Concept
title_sort establishment of the quantitative analysis of multiindex in euphorbia lathyris by the single marker method for euphorbia lathyris based on the quality by design concept
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8463240/
https://www.ncbi.nlm.nih.gov/pubmed/34567821
http://dx.doi.org/10.1155/2021/4311934
work_keys_str_mv AT xuehuafeng establishmentofthequantitativeanalysisofmultiindexineuphorbialathyrisbythesinglemarkermethodforeuphorbialathyrisbasedonthequalitybydesignconcept
AT guangjiaozhou establishmentofthequantitativeanalysisofmultiindexineuphorbialathyrisbythesinglemarkermethodforeuphorbialathyrisbasedonthequalitybydesignconcept
AT alitao establishmentofthequantitativeanalysisofmultiindexineuphorbialathyrisbythesinglemarkermethodforeuphorbialathyrisbasedonthequalitybydesignconcept