Cargando…
Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics
Applying microfluidic patterning, droplets were precisely generated on an electrowetting-on-dielectric (EWOD) chip considering these parameters: number of generating electrodes, number of cutting electrodes, voltage, frequency and gap between upper and lower plates of the electrode array on the EWOD...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464762/ https://www.ncbi.nlm.nih.gov/pubmed/34577747 http://dx.doi.org/10.3390/mi12091104 |
_version_ | 1784572697017057280 |
---|---|
author | Lin, Yi-Wei Ciou, Ying-Jhen Yao, Da-Jeng |
author_facet | Lin, Yi-Wei Ciou, Ying-Jhen Yao, Da-Jeng |
author_sort | Lin, Yi-Wei |
collection | PubMed |
description | Applying microfluidic patterning, droplets were precisely generated on an electrowetting-on-dielectric (EWOD) chip considering these parameters: number of generating electrodes, number of cutting electrodes, voltage, frequency and gap between upper and lower plates of the electrode array on the EWOD chip. In a subsequent patterning experiment, an environment with three generating electrodes, one cutting electrode and a gap height 10 μm, we obtained a quantitative volume for patterning. Propylene carbonate liquid and a mixed colloid of polyphthalate carbonate (PPC) and photosensitive polymer material were manipulated into varied patterns. With support from a Z-axis lifting platform and a UV lamp, a cured 3D structure was stacked. Using an EWOD system, a multi-layer three-dimensional structure was produced for the patterning. A two-plate EWOD system patterned propylene carbonate in a quantitative volume at 140 Vpp/20 kHz with automatic patterning. |
format | Online Article Text |
id | pubmed-8464762 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84647622021-09-27 Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics Lin, Yi-Wei Ciou, Ying-Jhen Yao, Da-Jeng Micromachines (Basel) Article Applying microfluidic patterning, droplets were precisely generated on an electrowetting-on-dielectric (EWOD) chip considering these parameters: number of generating electrodes, number of cutting electrodes, voltage, frequency and gap between upper and lower plates of the electrode array on the EWOD chip. In a subsequent patterning experiment, an environment with three generating electrodes, one cutting electrode and a gap height 10 μm, we obtained a quantitative volume for patterning. Propylene carbonate liquid and a mixed colloid of polyphthalate carbonate (PPC) and photosensitive polymer material were manipulated into varied patterns. With support from a Z-axis lifting platform and a UV lamp, a cured 3D structure was stacked. Using an EWOD system, a multi-layer three-dimensional structure was produced for the patterning. A two-plate EWOD system patterned propylene carbonate in a quantitative volume at 140 Vpp/20 kHz with automatic patterning. MDPI 2021-09-14 /pmc/articles/PMC8464762/ /pubmed/34577747 http://dx.doi.org/10.3390/mi12091104 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Lin, Yi-Wei Ciou, Ying-Jhen Yao, Da-Jeng Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics |
title | Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics |
title_full | Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics |
title_fullStr | Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics |
title_full_unstemmed | Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics |
title_short | Virtual Stencil for Patterning and Modeling in a Quantitative Volume Using EWOD and DEP Devices for Microfluidics |
title_sort | virtual stencil for patterning and modeling in a quantitative volume using ewod and dep devices for microfluidics |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464762/ https://www.ncbi.nlm.nih.gov/pubmed/34577747 http://dx.doi.org/10.3390/mi12091104 |
work_keys_str_mv | AT linyiwei virtualstencilforpatterningandmodelinginaquantitativevolumeusingewodanddepdevicesformicrofluidics AT ciouyingjhen virtualstencilforpatterningandmodelinginaquantitativevolumeusingewodanddepdevicesformicrofluidics AT yaodajeng virtualstencilforpatterningandmodelinginaquantitativevolumeusingewodanddepdevicesformicrofluidics |