Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study
Objectives: To compare the conspicuity of lobular breast cancers at digital breast tomosynthesis (DBT) versus synthesized 2D mammography (synt2D). Materials and methods: Seventy-six women (mean age 61.2 years, range 50–74 years) submitted to biopsy in our institution, from 2019 to 2021, with proven...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464936/ https://www.ncbi.nlm.nih.gov/pubmed/34564111 http://dx.doi.org/10.3390/jimaging7090185 |
_version_ | 1784572742447661056 |
---|---|
author | Romanucci, Giovanna Zantedeschi, Lisa Ventriglia, Anna Mercogliano, Sara Bisighin, Maria Vittoria Cugola, Loredana Bricolo, Paola Rella, Rossella Mandarà, Marta Benassuti, Chiara Caneva, Andrea Fornasa, Francesca |
author_facet | Romanucci, Giovanna Zantedeschi, Lisa Ventriglia, Anna Mercogliano, Sara Bisighin, Maria Vittoria Cugola, Loredana Bricolo, Paola Rella, Rossella Mandarà, Marta Benassuti, Chiara Caneva, Andrea Fornasa, Francesca |
author_sort | Romanucci, Giovanna |
collection | PubMed |
description | Objectives: To compare the conspicuity of lobular breast cancers at digital breast tomosynthesis (DBT) versus synthesized 2D mammography (synt2D). Materials and methods: Seventy-six women (mean age 61.2 years, range 50–74 years) submitted to biopsy in our institution, from 2019 to 2021, with proven invasive lobular breast cancer (ILC) were enrolled in this retrospective study. The participants underwent DBT and synt2D. Five breast radiologists, with different years of experience in breast imaging, independently assigned a conspicuity score (ordinal 6-point scale) to DBT and synt2D. Lesion conspicuity was compared, for each reader, between the synt2D overall conspicuity interpretation and DBT overall conspicuity interpretation using a Wilcoxon matched pairs test. Results: A total of 50/78 (64%) cancers were detected on both synt2D and DBT by all the readers, while 28/78 (26%) cancers where not recognized by at least one reader on synt2D. For each reader, in comparison with synt2D, DBT increased significantly the conspicuity of ILC (p < 0.0001). The raw proportion of high versus low conspicuity by modality confirmed that cancers were more likely to have high conspicuity at DBT than synt2D. Conclusions: ILCs were more likely to have high conspicuity at DBT than at synt2D, increasing the chances of the detection of ILC breast cancer. |
format | Online Article Text |
id | pubmed-8464936 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84649362021-10-28 Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study Romanucci, Giovanna Zantedeschi, Lisa Ventriglia, Anna Mercogliano, Sara Bisighin, Maria Vittoria Cugola, Loredana Bricolo, Paola Rella, Rossella Mandarà, Marta Benassuti, Chiara Caneva, Andrea Fornasa, Francesca J Imaging Article Objectives: To compare the conspicuity of lobular breast cancers at digital breast tomosynthesis (DBT) versus synthesized 2D mammography (synt2D). Materials and methods: Seventy-six women (mean age 61.2 years, range 50–74 years) submitted to biopsy in our institution, from 2019 to 2021, with proven invasive lobular breast cancer (ILC) were enrolled in this retrospective study. The participants underwent DBT and synt2D. Five breast radiologists, with different years of experience in breast imaging, independently assigned a conspicuity score (ordinal 6-point scale) to DBT and synt2D. Lesion conspicuity was compared, for each reader, between the synt2D overall conspicuity interpretation and DBT overall conspicuity interpretation using a Wilcoxon matched pairs test. Results: A total of 50/78 (64%) cancers were detected on both synt2D and DBT by all the readers, while 28/78 (26%) cancers where not recognized by at least one reader on synt2D. For each reader, in comparison with synt2D, DBT increased significantly the conspicuity of ILC (p < 0.0001). The raw proportion of high versus low conspicuity by modality confirmed that cancers were more likely to have high conspicuity at DBT than synt2D. Conclusions: ILCs were more likely to have high conspicuity at DBT than at synt2D, increasing the chances of the detection of ILC breast cancer. MDPI 2021-09-12 /pmc/articles/PMC8464936/ /pubmed/34564111 http://dx.doi.org/10.3390/jimaging7090185 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Romanucci, Giovanna Zantedeschi, Lisa Ventriglia, Anna Mercogliano, Sara Bisighin, Maria Vittoria Cugola, Loredana Bricolo, Paola Rella, Rossella Mandarà, Marta Benassuti, Chiara Caneva, Andrea Fornasa, Francesca Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study |
title | Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study |
title_full | Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study |
title_fullStr | Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study |
title_full_unstemmed | Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study |
title_short | Lobular Breast Cancer Conspicuity on Digital Breast Tomosynthesis Compared to Synthesized 2D Mammography: A Multireader Study |
title_sort | lobular breast cancer conspicuity on digital breast tomosynthesis compared to synthesized 2d mammography: a multireader study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464936/ https://www.ncbi.nlm.nih.gov/pubmed/34564111 http://dx.doi.org/10.3390/jimaging7090185 |
work_keys_str_mv | AT romanuccigiovanna lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT zantedeschilisa lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT ventrigliaanna lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT mercoglianosara lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT bisighinmariavittoria lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT cugolaloredana lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT bricolopaola lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT rellarossella lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT mandaramarta lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT benassutichiara lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT canevaandrea lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy AT fornasafrancesca lobularbreastcancerconspicuityondigitalbreasttomosynthesiscomparedtosynthesized2dmammographyamultireaderstudy |