Cargando…
Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance
Based on carboxylated multi-walled carbon nanotubes (MWCNTs-COOH), a MWCNTs/PVDF conductive membrane was prepared by a vacuum filtration cross-linking method. The surface compositions and morphology of conductive membranes were studied by X-ray photoelectron spectroscopy and high-resolution field em...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464980/ https://www.ncbi.nlm.nih.gov/pubmed/34564520 http://dx.doi.org/10.3390/membranes11090703 |
_version_ | 1784572753898110976 |
---|---|
author | Ding, Yi Guo, Zhansheng Dong, Xinan You, Hong Mei, Junxue Hou, Xuguang Liang, Zhenlin Li, Zhipeng |
author_facet | Ding, Yi Guo, Zhansheng Dong, Xinan You, Hong Mei, Junxue Hou, Xuguang Liang, Zhenlin Li, Zhipeng |
author_sort | Ding, Yi |
collection | PubMed |
description | Based on carboxylated multi-walled carbon nanotubes (MWCNTs-COOH), a MWCNTs/PVDF conductive membrane was prepared by a vacuum filtration cross-linking method. The surface compositions and morphology of conductive membranes were studied by X-ray photoelectron spectroscopy and high-resolution field emission scanning electron microscopy, respectively. The effects of cross-linked polymeric polyvinyl alcohol (PVA) on the conductive membrane properties such as the porosity, pore size distribution, pure water flux, conductivity, hydrophilicity, stability and antifouling properties were investigated. Results showed that the addition of PVA to the MWCNTs/PVDF conductive membrane decreased the pure water flux, porosity and the conductivity. However, the hydrophilicity of the modified MWCNTs/PVDF conductive membrane was greatly improved, and the contact angle of pure water was reduced from 70.18° to 25.48° with the addition of PVA contents from 0 wt% to 0.05 wt%. Meanwhile, the conductive membranes with higher content had a relatively higher stability. It was found that the conductive functional layer of the conductive membrane had an average mass loss rate of 1.22% in the 30 min ultrasonic oscillation experiment. The tensile intensity and break elongation ratio of the conductive membrane are improved by the addition of PVA, and the durability of the conductive membrane with PVA was superior to that without PVA added. The electric assisted anti-fouling experiments of modified conductive membrane indicated that compared with the condition without electric field, the average flux attenuation of the conductive membrane was reduced by 11.2%, and the membrane flux recovery rate reached 97.05%. Moreover, the addition of PVA could accelerate the clean of the conductive membranes. |
format | Online Article Text |
id | pubmed-8464980 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84649802021-09-27 Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance Ding, Yi Guo, Zhansheng Dong, Xinan You, Hong Mei, Junxue Hou, Xuguang Liang, Zhenlin Li, Zhipeng Membranes (Basel) Article Based on carboxylated multi-walled carbon nanotubes (MWCNTs-COOH), a MWCNTs/PVDF conductive membrane was prepared by a vacuum filtration cross-linking method. The surface compositions and morphology of conductive membranes were studied by X-ray photoelectron spectroscopy and high-resolution field emission scanning electron microscopy, respectively. The effects of cross-linked polymeric polyvinyl alcohol (PVA) on the conductive membrane properties such as the porosity, pore size distribution, pure water flux, conductivity, hydrophilicity, stability and antifouling properties were investigated. Results showed that the addition of PVA to the MWCNTs/PVDF conductive membrane decreased the pure water flux, porosity and the conductivity. However, the hydrophilicity of the modified MWCNTs/PVDF conductive membrane was greatly improved, and the contact angle of pure water was reduced from 70.18° to 25.48° with the addition of PVA contents from 0 wt% to 0.05 wt%. Meanwhile, the conductive membranes with higher content had a relatively higher stability. It was found that the conductive functional layer of the conductive membrane had an average mass loss rate of 1.22% in the 30 min ultrasonic oscillation experiment. The tensile intensity and break elongation ratio of the conductive membrane are improved by the addition of PVA, and the durability of the conductive membrane with PVA was superior to that without PVA added. The electric assisted anti-fouling experiments of modified conductive membrane indicated that compared with the condition without electric field, the average flux attenuation of the conductive membrane was reduced by 11.2%, and the membrane flux recovery rate reached 97.05%. Moreover, the addition of PVA could accelerate the clean of the conductive membranes. MDPI 2021-09-14 /pmc/articles/PMC8464980/ /pubmed/34564520 http://dx.doi.org/10.3390/membranes11090703 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ding, Yi Guo, Zhansheng Dong, Xinan You, Hong Mei, Junxue Hou, Xuguang Liang, Zhenlin Li, Zhipeng Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance |
title | Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance |
title_full | Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance |
title_fullStr | Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance |
title_full_unstemmed | Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance |
title_short | Preparation and Characterization of MWCNTs/PVDF Conductive Membrane with Cross-Linked Polymer PVA and Study on its Anti-Fouling Performance |
title_sort | preparation and characterization of mwcnts/pvdf conductive membrane with cross-linked polymer pva and study on its anti-fouling performance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8464980/ https://www.ncbi.nlm.nih.gov/pubmed/34564520 http://dx.doi.org/10.3390/membranes11090703 |
work_keys_str_mv | AT dingyi preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT guozhansheng preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT dongxinan preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT youhong preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT meijunxue preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT houxuguang preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT liangzhenlin preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance AT lizhipeng preparationandcharacterizationofmwcntspvdfconductivemembranewithcrosslinkedpolymerpvaandstudyonitsantifoulingperformance |