Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk

A composite material comprised of graphene nanoplatelet and silver particles (GNPs–AgPs) was used for the deposition of GNPs–AgPs’ nanofilms with cold plasma on silk. α-Cyclodextrin was used as a modifier of the active surface of the disposable sensor. The disposable stochastic sensor was used in sc...

Descripción completa

Detalles Bibliográficos
Autores principales: Gheorghe, Sorin Sebastian, Cioates Negut, Catalina, Badulescu, Marius, Stefan-van Staden, Raluca Ioana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8465493/
https://www.ncbi.nlm.nih.gov/pubmed/34575044
http://dx.doi.org/10.3390/life11090894
_version_ 1784572888309825536
author Gheorghe, Sorin Sebastian
Cioates Negut, Catalina
Badulescu, Marius
Stefan-van Staden, Raluca Ioana
author_facet Gheorghe, Sorin Sebastian
Cioates Negut, Catalina
Badulescu, Marius
Stefan-van Staden, Raluca Ioana
author_sort Gheorghe, Sorin Sebastian
collection PubMed
description A composite material comprised of graphene nanoplatelet and silver particles (GNPs–AgPs) was used for the deposition of GNPs–AgPs’ nanofilms with cold plasma on silk. α-Cyclodextrin was used as a modifier of the active surface of the disposable sensor. The disposable stochastic sensor was used in screening tests for the assay of heregulin-α in whole blood and tissue samples. The disposable stochastic sensor showed a low limit of determination (4.10 fg mL(−1)) and can be used with high sensitivity on a wide concentration range (4.10 fg mL(−1)–0.04 µg mL(−1)). The screening method was validated against ELISA when good correlations (confirmed also by the t-test) were obtained.
format Online
Article
Text
id pubmed-8465493
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84654932021-09-27 Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk Gheorghe, Sorin Sebastian Cioates Negut, Catalina Badulescu, Marius Stefan-van Staden, Raluca Ioana Life (Basel) Article A composite material comprised of graphene nanoplatelet and silver particles (GNPs–AgPs) was used for the deposition of GNPs–AgPs’ nanofilms with cold plasma on silk. α-Cyclodextrin was used as a modifier of the active surface of the disposable sensor. The disposable stochastic sensor was used in screening tests for the assay of heregulin-α in whole blood and tissue samples. The disposable stochastic sensor showed a low limit of determination (4.10 fg mL(−1)) and can be used with high sensitivity on a wide concentration range (4.10 fg mL(−1)–0.04 µg mL(−1)). The screening method was validated against ELISA when good correlations (confirmed also by the t-test) were obtained. MDPI 2021-08-29 /pmc/articles/PMC8465493/ /pubmed/34575044 http://dx.doi.org/10.3390/life11090894 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Gheorghe, Sorin Sebastian
Cioates Negut, Catalina
Badulescu, Marius
Stefan-van Staden, Raluca Ioana
Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk
title Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk
title_full Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk
title_fullStr Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk
title_full_unstemmed Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk
title_short Sensitive Detection of Heregulin-α from Biological Samples Using a Disposable Stochastic Sensor Based on Plasma Deposition of GNPs–AgPs’ Nanofilms on Silk
title_sort sensitive detection of heregulin-α from biological samples using a disposable stochastic sensor based on plasma deposition of gnps–agps’ nanofilms on silk
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8465493/
https://www.ncbi.nlm.nih.gov/pubmed/34575044
http://dx.doi.org/10.3390/life11090894
work_keys_str_mv AT gheorghesorinsebastian sensitivedetectionofheregulinafrombiologicalsamplesusingadisposablestochasticsensorbasedonplasmadepositionofgnpsagpsnanofilmsonsilk
AT cioatesnegutcatalina sensitivedetectionofheregulinafrombiologicalsamplesusingadisposablestochasticsensorbasedonplasmadepositionofgnpsagpsnanofilmsonsilk
AT badulescumarius sensitivedetectionofheregulinafrombiologicalsamplesusingadisposablestochasticsensorbasedonplasmadepositionofgnpsagpsnanofilmsonsilk
AT stefanvanstadenralucaioana sensitivedetectionofheregulinafrombiologicalsamplesusingadisposablestochasticsensorbasedonplasmadepositionofgnpsagpsnanofilmsonsilk