Cargando…

Helicopter Inside Cabin Acoustic Evaluation: A Case Study—IAR PUMA 330

This paper presents an inside-cabin acoustic evaluation of the IAR PUMA 330 helicopter, manufactured by IAR S.A. Brasov. In this study, based on the acoustic assessment inside the helicopter, areas with high noise levels are identified. In this regard, several tests were carried out in accordance wi...

Descripción completa

Detalles Bibliográficos
Autores principales: Deaconu, Marius, Cican, Grigore, Toma, Adina-Cristina, Drăgășanu, Luminița Ioana
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8465724/
https://www.ncbi.nlm.nih.gov/pubmed/34574638
http://dx.doi.org/10.3390/ijerph18189716
Descripción
Sumario:This paper presents an inside-cabin acoustic evaluation of the IAR PUMA 330 helicopter, manufactured by IAR S.A. Brasov. In this study, based on the acoustic assessment inside the helicopter, areas with high noise levels are identified. In this regard, several tests were carried out in accordance with the ISO 5129 standard. In the first stage of the assessment, a measurement campaign was performed to identify the acoustic leaks from the outside noise sources propagating inside the cabin (in the door area) and the acoustic attenuation of the helicopter structure. These tests were performed on the factory runway, with the helicopter in parked position (ground tests). During the ground tests, the helicopter engines were turned off. The tests consisted of placing two loudspeakers directed towards the helicopter door and generating pink noise. Inside the helicopter, the entire door frame opening was scanned with an intensity probe to identify acoustic leaks areas. The second assessment stage was to determine the areas of the cabin with the highest levels of noise. Within the measurement campaign, 16 microphones were placed inside the cabin, at the level of the passengers’ heads, arranged in seven zones. The tests were carried out with the helicopter engines started, staying at fixed point above the ground (hovering), and then a flight test, in which all the maneuvers necessary for the use of the helicopter were performed (in-flight tests). Based on the measurement results, it was possible to highlight the noise spectral components in each of the seven areas. The noise assessment revealed high noise levels inside the cabin, having as main noise sources the transmission gear and the door area, leading to the need for reducing the noise exposure for passengers and crew, thus the need to reduce noise levels inside the helicopter.