Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study

Background and Objectives: To evaluate the condensation and the microarchitecture of implant bed walls of sites prepared with counterclockwise drilling with tapered implant drills using optical coherence tomography. Materials and Methods: Four drill designs with different wall and tip angles were us...

Descripción completa

Detalles Bibliográficos
Autores principales: Delgado-Ruiz, Rafael, Mahdian, Mina, Benezha, Ilyasse, Romanos, Georgios
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8467273/
https://www.ncbi.nlm.nih.gov/pubmed/34577863
http://dx.doi.org/10.3390/medicina57090940
_version_ 1784573355153686528
author Delgado-Ruiz, Rafael
Mahdian, Mina
Benezha, Ilyasse
Romanos, Georgios
author_facet Delgado-Ruiz, Rafael
Mahdian, Mina
Benezha, Ilyasse
Romanos, Georgios
author_sort Delgado-Ruiz, Rafael
collection PubMed
description Background and Objectives: To evaluate the condensation and the microarchitecture of implant bed walls of sites prepared with counterclockwise drilling with tapered implant drills using optical coherence tomography. Materials and Methods: Four drill designs with different wall and tip angles were used. Polyurethane laminas resembling type IV bone microarchitecture were superimposed and clamped with a vice to simulate the coronal, middle, and apical aspects of the implant site. Twenty implant beds were prepared at 1200 rpm in clockwise (control) and counterclockwise (test) directions (N = 160). Optical coherence tomography (OCT) was used to evaluate the condensation and microarchitecture characteristics of the implant bed walls. The relative condensation was calculated using the Image J software Bone application. The microarchitecture was evaluated in reconstructed 3D volumes in XY, XZ, and YZ sections. Statistical analysis was performed using one-way ANOVA. Dunnet test was applied to determine differences between groups. Significance was set as p < 0.05. Results: Counterclockwise drilling (Test) condensed and changed the microarchitecture of the apical regions for all the implant beds in all of the groups when compared to clockwise drilling (control). The apical region of test groups showed the highest relative bone condensation (p = 0.026) when compared to controls. Conclusions: The direction of rotation (counterclockwise drilling) and not the design of tapered drills (tip and wall angles) is responsible for the condensation at the apical area observed in polyurethane blocks. The OCT method can be used for the evaluation of changes in density and microstructure of polyurethane blocks.
format Online
Article
Text
id pubmed-8467273
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84672732021-09-27 Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study Delgado-Ruiz, Rafael Mahdian, Mina Benezha, Ilyasse Romanos, Georgios Medicina (Kaunas) Article Background and Objectives: To evaluate the condensation and the microarchitecture of implant bed walls of sites prepared with counterclockwise drilling with tapered implant drills using optical coherence tomography. Materials and Methods: Four drill designs with different wall and tip angles were used. Polyurethane laminas resembling type IV bone microarchitecture were superimposed and clamped with a vice to simulate the coronal, middle, and apical aspects of the implant site. Twenty implant beds were prepared at 1200 rpm in clockwise (control) and counterclockwise (test) directions (N = 160). Optical coherence tomography (OCT) was used to evaluate the condensation and microarchitecture characteristics of the implant bed walls. The relative condensation was calculated using the Image J software Bone application. The microarchitecture was evaluated in reconstructed 3D volumes in XY, XZ, and YZ sections. Statistical analysis was performed using one-way ANOVA. Dunnet test was applied to determine differences between groups. Significance was set as p < 0.05. Results: Counterclockwise drilling (Test) condensed and changed the microarchitecture of the apical regions for all the implant beds in all of the groups when compared to clockwise drilling (control). The apical region of test groups showed the highest relative bone condensation (p = 0.026) when compared to controls. Conclusions: The direction of rotation (counterclockwise drilling) and not the design of tapered drills (tip and wall angles) is responsible for the condensation at the apical area observed in polyurethane blocks. The OCT method can be used for the evaluation of changes in density and microstructure of polyurethane blocks. MDPI 2021-09-06 /pmc/articles/PMC8467273/ /pubmed/34577863 http://dx.doi.org/10.3390/medicina57090940 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Delgado-Ruiz, Rafael
Mahdian, Mina
Benezha, Ilyasse
Romanos, Georgios
Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study
title Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study
title_full Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study
title_fullStr Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study
title_full_unstemmed Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study
title_short Counterclockwise Drilling with Different Tapered Drills Condenses the Implant Bed—An Optical Coherence Tomography In Vitro Study
title_sort counterclockwise drilling with different tapered drills condenses the implant bed—an optical coherence tomography in vitro study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8467273/
https://www.ncbi.nlm.nih.gov/pubmed/34577863
http://dx.doi.org/10.3390/medicina57090940
work_keys_str_mv AT delgadoruizrafael counterclockwisedrillingwithdifferenttapereddrillscondensestheimplantbedanopticalcoherencetomographyinvitrostudy
AT mahdianmina counterclockwisedrillingwithdifferenttapereddrillscondensestheimplantbedanopticalcoherencetomographyinvitrostudy
AT benezhailyasse counterclockwisedrillingwithdifferenttapereddrillscondensestheimplantbedanopticalcoherencetomographyinvitrostudy
AT romanosgeorgios counterclockwisedrillingwithdifferenttapereddrillscondensestheimplantbedanopticalcoherencetomographyinvitrostudy