Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers

We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chambe...

Descripción completa

Detalles Bibliográficos
Autores principales: Yang, Dapeng, Wang, Xiaohuan, Sun, Junze, Chen, Heng, Ju, Chenhao, Lin, Tingting, Tian, Baofeng, Zheng, Fan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8467773/
https://www.ncbi.nlm.nih.gov/pubmed/34577651
http://dx.doi.org/10.3390/mi12091008
_version_ 1784573485011435520
author Yang, Dapeng
Wang, Xiaohuan
Sun, Junze
Chen, Heng
Ju, Chenhao
Lin, Tingting
Tian, Baofeng
Zheng, Fan
author_facet Yang, Dapeng
Wang, Xiaohuan
Sun, Junze
Chen, Heng
Ju, Chenhao
Lin, Tingting
Tian, Baofeng
Zheng, Fan
author_sort Yang, Dapeng
collection PubMed
description We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chamber. Then, it is diverged into the shunt channels, pumped into reflux channels and merged by a fluid pump. The velocities of shunt flows are measured by two electrochemical transducers. The feasibility of the method was demonstrated in theory, and a 2D finite element model was built to simulate the dynamics of the liquid jet gyroscope. Simulation results confirm the effectiveness of the gyroscope, which has higher sensitivity in the near DC frequency band.
format Online
Article
Text
id pubmed-8467773
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84677732021-09-27 Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers Yang, Dapeng Wang, Xiaohuan Sun, Junze Chen, Heng Ju, Chenhao Lin, Tingting Tian, Baofeng Zheng, Fan Micromachines (Basel) Article We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chamber. Then, it is diverged into the shunt channels, pumped into reflux channels and merged by a fluid pump. The velocities of shunt flows are measured by two electrochemical transducers. The feasibility of the method was demonstrated in theory, and a 2D finite element model was built to simulate the dynamics of the liquid jet gyroscope. Simulation results confirm the effectiveness of the gyroscope, which has higher sensitivity in the near DC frequency band. MDPI 2021-08-24 /pmc/articles/PMC8467773/ /pubmed/34577651 http://dx.doi.org/10.3390/mi12091008 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yang, Dapeng
Wang, Xiaohuan
Sun, Junze
Chen, Heng
Ju, Chenhao
Lin, Tingting
Tian, Baofeng
Zheng, Fan
Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
title Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
title_full Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
title_fullStr Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
title_full_unstemmed Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
title_short Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
title_sort design, modeling and simulation of a liquid jet gyroscope based on electrochemical transducers
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8467773/
https://www.ncbi.nlm.nih.gov/pubmed/34577651
http://dx.doi.org/10.3390/mi12091008
work_keys_str_mv AT yangdapeng designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT wangxiaohuan designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT sunjunze designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT chenheng designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT juchenhao designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT lintingting designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT tianbaofeng designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers
AT zhengfan designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers