Cargando…
Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers
We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chambe...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8467773/ https://www.ncbi.nlm.nih.gov/pubmed/34577651 http://dx.doi.org/10.3390/mi12091008 |
_version_ | 1784573485011435520 |
---|---|
author | Yang, Dapeng Wang, Xiaohuan Sun, Junze Chen, Heng Ju, Chenhao Lin, Tingting Tian, Baofeng Zheng, Fan |
author_facet | Yang, Dapeng Wang, Xiaohuan Sun, Junze Chen, Heng Ju, Chenhao Lin, Tingting Tian, Baofeng Zheng, Fan |
author_sort | Yang, Dapeng |
collection | PubMed |
description | We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chamber. Then, it is diverged into the shunt channels, pumped into reflux channels and merged by a fluid pump. The velocities of shunt flows are measured by two electrochemical transducers. The feasibility of the method was demonstrated in theory, and a 2D finite element model was built to simulate the dynamics of the liquid jet gyroscope. Simulation results confirm the effectiveness of the gyroscope, which has higher sensitivity in the near DC frequency band. |
format | Online Article Text |
id | pubmed-8467773 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84677732021-09-27 Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers Yang, Dapeng Wang, Xiaohuan Sun, Junze Chen, Heng Ju, Chenhao Lin, Tingting Tian, Baofeng Zheng, Fan Micromachines (Basel) Article We propose a novel liquid jet gyroscope based on electrochemical transducers, which uses electrolyte as the jet medium, and two electrochemical transducers placed symmetrically as the velocity measuring unit. The gyroscope includes a fluid pump to generate a jet flow, which flows into the jet chamber. Then, it is diverged into the shunt channels, pumped into reflux channels and merged by a fluid pump. The velocities of shunt flows are measured by two electrochemical transducers. The feasibility of the method was demonstrated in theory, and a 2D finite element model was built to simulate the dynamics of the liquid jet gyroscope. Simulation results confirm the effectiveness of the gyroscope, which has higher sensitivity in the near DC frequency band. MDPI 2021-08-24 /pmc/articles/PMC8467773/ /pubmed/34577651 http://dx.doi.org/10.3390/mi12091008 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yang, Dapeng Wang, Xiaohuan Sun, Junze Chen, Heng Ju, Chenhao Lin, Tingting Tian, Baofeng Zheng, Fan Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers |
title | Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers |
title_full | Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers |
title_fullStr | Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers |
title_full_unstemmed | Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers |
title_short | Design, Modeling and Simulation of a Liquid Jet Gyroscope Based on Electrochemical Transducers |
title_sort | design, modeling and simulation of a liquid jet gyroscope based on electrochemical transducers |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8467773/ https://www.ncbi.nlm.nih.gov/pubmed/34577651 http://dx.doi.org/10.3390/mi12091008 |
work_keys_str_mv | AT yangdapeng designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT wangxiaohuan designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT sunjunze designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT chenheng designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT juchenhao designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT lintingting designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT tianbaofeng designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers AT zhengfan designmodelingandsimulationofaliquidjetgyroscopebasedonelectrochemicaltransducers |