Cargando…

Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC

To ensure the quality of concrete construction, the workability of fresh mix measured by rational test methods is critical to be controlled. With the presence of steel fibers, whether the test methods and evaluation indices of fresh self-compacting concrete (SCC) are adaptable for self-compacting st...

Descripción completa

Detalles Bibliográficos
Autores principales: Ding, Xinxin, Geng, Haibin, Shi, Kang, Song, Li, Li, Shangyu, Liu, Guirong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8468712/
https://www.ncbi.nlm.nih.gov/pubmed/34576537
http://dx.doi.org/10.3390/ma14185312
_version_ 1784573741506756608
author Ding, Xinxin
Geng, Haibin
Shi, Kang
Song, Li
Li, Shangyu
Liu, Guirong
author_facet Ding, Xinxin
Geng, Haibin
Shi, Kang
Song, Li
Li, Shangyu
Liu, Guirong
author_sort Ding, Xinxin
collection PubMed
description To ensure the quality of concrete construction, the workability of fresh mix measured by rational test methods is critical to be controlled. With the presence of steel fibers, whether the test methods and evaluation indices of fresh self-compacting concrete (SCC) are adaptable for self-compacting steel fiber reinforced concrete (SFRC) needs to be systematically verified. In this paper, seven groups of self-compacting SFRC, referenced with one group SCC, were prepared by using the mix proportion design method based on the steel fiber-aggregates skeleton packing test. The main factors included the volume fraction and the length of hooked-end steel fiber. Tests for filling ability, passing ability, and stability of fresh self-compacting SFRC and SCC were carried out. Results indicate that the adaptability was well for the slump-flow test with indices of slump flow and flow time T(500) to evaluate the filling ability, the J-ring flow test with an index of PA level to evaluate the passing ability, and the static segregation test with an index of static segregation resistance to evaluate the stability of fresh self-compacting SFRC. By the repeated tests and measurements, the slump cone should be vertically lifted off to a height of 300 mm within 3 s at a constant speed, the spacing of the rebar in the J-ring test should be adjusted to be two times the fiber length. If the table jumping test is used, the dynamic segregation percent should be increased to 35% to fit the result of the static segregation test. Good workability of the self-compacting SFRC prepared in this study is presented with the general evaluation of test results.
format Online
Article
Text
id pubmed-8468712
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84687122021-09-27 Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC Ding, Xinxin Geng, Haibin Shi, Kang Song, Li Li, Shangyu Liu, Guirong Materials (Basel) Article To ensure the quality of concrete construction, the workability of fresh mix measured by rational test methods is critical to be controlled. With the presence of steel fibers, whether the test methods and evaluation indices of fresh self-compacting concrete (SCC) are adaptable for self-compacting steel fiber reinforced concrete (SFRC) needs to be systematically verified. In this paper, seven groups of self-compacting SFRC, referenced with one group SCC, were prepared by using the mix proportion design method based on the steel fiber-aggregates skeleton packing test. The main factors included the volume fraction and the length of hooked-end steel fiber. Tests for filling ability, passing ability, and stability of fresh self-compacting SFRC and SCC were carried out. Results indicate that the adaptability was well for the slump-flow test with indices of slump flow and flow time T(500) to evaluate the filling ability, the J-ring flow test with an index of PA level to evaluate the passing ability, and the static segregation test with an index of static segregation resistance to evaluate the stability of fresh self-compacting SFRC. By the repeated tests and measurements, the slump cone should be vertically lifted off to a height of 300 mm within 3 s at a constant speed, the spacing of the rebar in the J-ring test should be adjusted to be two times the fiber length. If the table jumping test is used, the dynamic segregation percent should be increased to 35% to fit the result of the static segregation test. Good workability of the self-compacting SFRC prepared in this study is presented with the general evaluation of test results. MDPI 2021-09-15 /pmc/articles/PMC8468712/ /pubmed/34576537 http://dx.doi.org/10.3390/ma14185312 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Ding, Xinxin
Geng, Haibin
Shi, Kang
Song, Li
Li, Shangyu
Liu, Guirong
Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC
title Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC
title_full Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC
title_fullStr Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC
title_full_unstemmed Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC
title_short Study on Adaptability of Test Methods for Workability of Fresh Self-Compacting SFRC
title_sort study on adaptability of test methods for workability of fresh self-compacting sfrc
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8468712/
https://www.ncbi.nlm.nih.gov/pubmed/34576537
http://dx.doi.org/10.3390/ma14185312
work_keys_str_mv AT dingxinxin studyonadaptabilityoftestmethodsforworkabilityoffreshselfcompactingsfrc
AT genghaibin studyonadaptabilityoftestmethodsforworkabilityoffreshselfcompactingsfrc
AT shikang studyonadaptabilityoftestmethodsforworkabilityoffreshselfcompactingsfrc
AT songli studyonadaptabilityoftestmethodsforworkabilityoffreshselfcompactingsfrc
AT lishangyu studyonadaptabilityoftestmethodsforworkabilityoffreshselfcompactingsfrc
AT liuguirong studyonadaptabilityoftestmethodsforworkabilityoffreshselfcompactingsfrc