Cargando…

The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine

Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Purgat, Krystian, Kośka, Izabella, Kubalczyk, Paweł
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8468900/
https://www.ncbi.nlm.nih.gov/pubmed/34577158
http://dx.doi.org/10.3390/molecules26185687
_version_ 1784573791335088128
author Purgat, Krystian
Kośka, Izabella
Kubalczyk, Paweł
author_facet Purgat, Krystian
Kośka, Izabella
Kubalczyk, Paweł
author_sort Purgat, Krystian
collection PubMed
description Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with field amplified sample injection (FASI). The off-line SDME protocol consists of the following steps: urine dilution with 0.2 mol/L, pH 8.2 phosphate buffer (1:2, v/v), chloroform addition, drop formation and extraction of HTL. The pre-concentration of HTL inside a separation capillary was performed by FASI. For sample separation, the 0.1 mol/L pH 4.75 phosphate buffer served as the background electrolyte, and HTL was detected at 240 nm. A standard fused-silica capillary (effective length 55.5 cm, 75 μm id) and a separation voltage of 21 kV (~99 μA) were used. Electrophoretic separation was completed within 7 min, whereas the LOD and LOQ for HTL were 0.04 and 0.1 μmol/L urine, respectively. The calibration curve in urine was linear in the range of 0.1–0.5 μmol/L, with R(2) = 0.9991. The relative standard deviation of the points of the calibration curve varied from 2.4% to 14.9%. The intra- and inter-day precision and recovery were 6.4–10.2% (average 6.0% and 6.7%) and 94.9–102.7% (average 99.7% and 99.5%), respectively. The analytical procedure was successfully applied to the analysis of spiked urine samples obtained from apparently healthy volunteers.
format Online
Article
Text
id pubmed-8468900
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84689002021-09-27 The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine Purgat, Krystian Kośka, Izabella Kubalczyk, Paweł Molecules Article Two cheap, simple and reproducible methods for the electrophoretic determination of homocysteine thiolactone (HTL) in human urine have been developed and validated. The first method utilizes off-line single drop microextraction (SDME), whereas the second one uses off-line SDME in combination with field amplified sample injection (FASI). The off-line SDME protocol consists of the following steps: urine dilution with 0.2 mol/L, pH 8.2 phosphate buffer (1:2, v/v), chloroform addition, drop formation and extraction of HTL. The pre-concentration of HTL inside a separation capillary was performed by FASI. For sample separation, the 0.1 mol/L pH 4.75 phosphate buffer served as the background electrolyte, and HTL was detected at 240 nm. A standard fused-silica capillary (effective length 55.5 cm, 75 μm id) and a separation voltage of 21 kV (~99 μA) were used. Electrophoretic separation was completed within 7 min, whereas the LOD and LOQ for HTL were 0.04 and 0.1 μmol/L urine, respectively. The calibration curve in urine was linear in the range of 0.1–0.5 μmol/L, with R(2) = 0.9991. The relative standard deviation of the points of the calibration curve varied from 2.4% to 14.9%. The intra- and inter-day precision and recovery were 6.4–10.2% (average 6.0% and 6.7%) and 94.9–102.7% (average 99.7% and 99.5%), respectively. The analytical procedure was successfully applied to the analysis of spiked urine samples obtained from apparently healthy volunteers. MDPI 2021-09-20 /pmc/articles/PMC8468900/ /pubmed/34577158 http://dx.doi.org/10.3390/molecules26185687 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Purgat, Krystian
Kośka, Izabella
Kubalczyk, Paweł
The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine
title The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine
title_full The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine
title_fullStr The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine
title_full_unstemmed The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine
title_short The Use of Single Drop Microextraction and Field Amplified Sample Injection for CZE Determination of Homocysteine Thiolactone in Urine
title_sort use of single drop microextraction and field amplified sample injection for cze determination of homocysteine thiolactone in urine
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8468900/
https://www.ncbi.nlm.nih.gov/pubmed/34577158
http://dx.doi.org/10.3390/molecules26185687
work_keys_str_mv AT purgatkrystian theuseofsingledropmicroextractionandfieldamplifiedsampleinjectionforczedeterminationofhomocysteinethiolactoneinurine
AT koskaizabella theuseofsingledropmicroextractionandfieldamplifiedsampleinjectionforczedeterminationofhomocysteinethiolactoneinurine
AT kubalczykpaweł theuseofsingledropmicroextractionandfieldamplifiedsampleinjectionforczedeterminationofhomocysteinethiolactoneinurine
AT purgatkrystian useofsingledropmicroextractionandfieldamplifiedsampleinjectionforczedeterminationofhomocysteinethiolactoneinurine
AT koskaizabella useofsingledropmicroextractionandfieldamplifiedsampleinjectionforczedeterminationofhomocysteinethiolactoneinurine
AT kubalczykpaweł useofsingledropmicroextractionandfieldamplifiedsampleinjectionforczedeterminationofhomocysteinethiolactoneinurine