Cargando…

Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique

One of the recently evolving methods for cyanide determination in body fluids is GC-MS, following extractive alkylation with pentafluorobenzyl bromide or pentafluorobenzyl p-toluenesulfonate. The aim of this study was to improve previous GC methods by utilizing a triple quadrupole mass spectrometer,...

Descripción completa

Detalles Bibliográficos
Autores principales: Osak, Marcin, Buszewicz, Grzegorz, Baj, Jacek, Teresiński, Grzegorz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469058/
https://www.ncbi.nlm.nih.gov/pubmed/34577109
http://dx.doi.org/10.3390/molecules26185638
_version_ 1784573832896446464
author Osak, Marcin
Buszewicz, Grzegorz
Baj, Jacek
Teresiński, Grzegorz
author_facet Osak, Marcin
Buszewicz, Grzegorz
Baj, Jacek
Teresiński, Grzegorz
author_sort Osak, Marcin
collection PubMed
description One of the recently evolving methods for cyanide determination in body fluids is GC-MS, following extractive alkylation with pentafluorobenzyl bromide or pentafluorobenzyl p-toluenesulfonate. The aim of this study was to improve previous GC methods by utilizing a triple quadrupole mass spectrometer, which could enhance selectivity and sensitivity allowing for the reliable confirmation of cyanide exposure in toxicological studies. Another purpose of this study was to facilitate a case investigation including a determination of cyanide in blood and to use the obtained data to confirm the ingestion of a substance, found together with a human corpse at the forensic scene. The blood samples were prepared following extractive alkylation with a phase transfer catalyst tetrabutylammonium sulfate and the PFB-Br derivatization agent. Optimal parameters for detection, including ionization type and multiple reaction monitoring (MRM) transitions had been investigated and then selected. The validation parameters for the above method were as follows—linear regression R(2) = 0.9997 in the range of 0.1 µg/mL to 10 µg/mL; LOD = 24 ng/mL; LOQ = 80 ng/mL and an average recovery of extraction of 98%. Our study demonstrates the first attempt of cyanide determination in blood with gas chromatography-tandem mass spectrometry. The established method could be applied in forensic studies due to MS/MS confirmation of organic cyanide derivative and low matrix interferences owning to utilizing negative chemical ionization.
format Online
Article
Text
id pubmed-8469058
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84690582021-09-27 Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique Osak, Marcin Buszewicz, Grzegorz Baj, Jacek Teresiński, Grzegorz Molecules Article One of the recently evolving methods for cyanide determination in body fluids is GC-MS, following extractive alkylation with pentafluorobenzyl bromide or pentafluorobenzyl p-toluenesulfonate. The aim of this study was to improve previous GC methods by utilizing a triple quadrupole mass spectrometer, which could enhance selectivity and sensitivity allowing for the reliable confirmation of cyanide exposure in toxicological studies. Another purpose of this study was to facilitate a case investigation including a determination of cyanide in blood and to use the obtained data to confirm the ingestion of a substance, found together with a human corpse at the forensic scene. The blood samples were prepared following extractive alkylation with a phase transfer catalyst tetrabutylammonium sulfate and the PFB-Br derivatization agent. Optimal parameters for detection, including ionization type and multiple reaction monitoring (MRM) transitions had been investigated and then selected. The validation parameters for the above method were as follows—linear regression R(2) = 0.9997 in the range of 0.1 µg/mL to 10 µg/mL; LOD = 24 ng/mL; LOQ = 80 ng/mL and an average recovery of extraction of 98%. Our study demonstrates the first attempt of cyanide determination in blood with gas chromatography-tandem mass spectrometry. The established method could be applied in forensic studies due to MS/MS confirmation of organic cyanide derivative and low matrix interferences owning to utilizing negative chemical ionization. MDPI 2021-09-17 /pmc/articles/PMC8469058/ /pubmed/34577109 http://dx.doi.org/10.3390/molecules26185638 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Osak, Marcin
Buszewicz, Grzegorz
Baj, Jacek
Teresiński, Grzegorz
Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique
title Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique
title_full Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique
title_fullStr Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique
title_full_unstemmed Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique
title_short Determination of Cyanide in Blood for Forensic Toxicology Purposes—A Novel Nci Gc-Ms/Ms Technique
title_sort determination of cyanide in blood for forensic toxicology purposes—a novel nci gc-ms/ms technique
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469058/
https://www.ncbi.nlm.nih.gov/pubmed/34577109
http://dx.doi.org/10.3390/molecules26185638
work_keys_str_mv AT osakmarcin determinationofcyanideinbloodforforensictoxicologypurposesanovelncigcmsmstechnique
AT buszewiczgrzegorz determinationofcyanideinbloodforforensictoxicologypurposesanovelncigcmsmstechnique
AT bajjacek determinationofcyanideinbloodforforensictoxicologypurposesanovelncigcmsmstechnique
AT teresinskigrzegorz determinationofcyanideinbloodforforensictoxicologypurposesanovelncigcmsmstechnique