Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet data...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469191/ https://www.ncbi.nlm.nih.gov/pubmed/34577471 http://dx.doi.org/10.3390/s21186264 |
_version_ | 1784573867363139584 |
---|---|
author | Sadrawi, Muammar Lin, Yin-Tsong Lin, Chien-Hung Mathunjwa, Bhekumuzi Hsin, Ho-Tsung Fan, Shou-Zen Abbod, Maysam F. Shieh, Jiann-Shing |
author_facet | Sadrawi, Muammar Lin, Yin-Tsong Lin, Chien-Hung Mathunjwa, Bhekumuzi Hsin, Ho-Tsung Fan, Shou-Zen Abbod, Maysam F. Shieh, Jiann-Shing |
author_sort | Sadrawi, Muammar |
collection | PubMed |
description | This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet database are used for cardiovascular and cerebral hemodynamics, respectively. For cardiovascular hemodynamics, the ECG is used for generating the arterial blood pressure (ABP), central venous pressure (CVP), and pulmonary arterial pressure (PAP). Meanwhile, for cerebral hemodynamics, the ECG is utilized for the intracranial pressure (ICP) generator. A deep convolutional autoencoder system is applied for this study. The cross-validation method with Pearson’s linear correlation (R), root mean squared error (RMSE), and mean absolute error (MAE) are measured for the evaluations. Initially, the ECG is used to generate the cardiovascular waveform. For the ABP system—the systolic blood pressure (SBP) and diastolic blood pressures (DBP)—the R evaluations are 0.894 ± 0.004 and 0.881 ± 0.005, respectively. The MAE evaluations for SBP and DBP are, respectively, 6.645 ± 0.353 mmHg and 3.210 ± 0.104 mmHg. Furthermore, for the PAP system—the systolic and diastolic pressures—the R evaluations are 0.864 ± 0.003 mmHg and 0.817 ± 0.006 mmHg, respectively. The MAE evaluations for systolic and diastolic pressures are, respectively, 3.847 ± 0.136 mmHg and 2.964 ± 0.181 mmHg. Meanwhile, the mean CVP evaluations are 0.916 ± 0.001, 2.220 ± 0.039 mmHg, and 1.329 ± 0.036 mmHg, respectively, for R, RMSE, and MAE. For the mean ICP evaluation in cerebral hemodynamics, the R and MAE evaluations are 0.914 ± 0.003 and 2.404 ± 0.043 mmHg, respectively. This study, as a proof of concept, concludes that the non-invasive cardiovascular and cerebral hemodynamics systems can be potentially investigated by only using the ECG signal. |
format | Online Article Text |
id | pubmed-8469191 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84691912021-09-27 Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder Sadrawi, Muammar Lin, Yin-Tsong Lin, Chien-Hung Mathunjwa, Bhekumuzi Hsin, Ho-Tsung Fan, Shou-Zen Abbod, Maysam F. Shieh, Jiann-Shing Sensors (Basel) Article This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet database are used for cardiovascular and cerebral hemodynamics, respectively. For cardiovascular hemodynamics, the ECG is used for generating the arterial blood pressure (ABP), central venous pressure (CVP), and pulmonary arterial pressure (PAP). Meanwhile, for cerebral hemodynamics, the ECG is utilized for the intracranial pressure (ICP) generator. A deep convolutional autoencoder system is applied for this study. The cross-validation method with Pearson’s linear correlation (R), root mean squared error (RMSE), and mean absolute error (MAE) are measured for the evaluations. Initially, the ECG is used to generate the cardiovascular waveform. For the ABP system—the systolic blood pressure (SBP) and diastolic blood pressures (DBP)—the R evaluations are 0.894 ± 0.004 and 0.881 ± 0.005, respectively. The MAE evaluations for SBP and DBP are, respectively, 6.645 ± 0.353 mmHg and 3.210 ± 0.104 mmHg. Furthermore, for the PAP system—the systolic and diastolic pressures—the R evaluations are 0.864 ± 0.003 mmHg and 0.817 ± 0.006 mmHg, respectively. The MAE evaluations for systolic and diastolic pressures are, respectively, 3.847 ± 0.136 mmHg and 2.964 ± 0.181 mmHg. Meanwhile, the mean CVP evaluations are 0.916 ± 0.001, 2.220 ± 0.039 mmHg, and 1.329 ± 0.036 mmHg, respectively, for R, RMSE, and MAE. For the mean ICP evaluation in cerebral hemodynamics, the R and MAE evaluations are 0.914 ± 0.003 and 2.404 ± 0.043 mmHg, respectively. This study, as a proof of concept, concludes that the non-invasive cardiovascular and cerebral hemodynamics systems can be potentially investigated by only using the ECG signal. MDPI 2021-09-18 /pmc/articles/PMC8469191/ /pubmed/34577471 http://dx.doi.org/10.3390/s21186264 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Sadrawi, Muammar Lin, Yin-Tsong Lin, Chien-Hung Mathunjwa, Bhekumuzi Hsin, Ho-Tsung Fan, Shou-Zen Abbod, Maysam F. Shieh, Jiann-Shing Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder |
title | Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder |
title_full | Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder |
title_fullStr | Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder |
title_full_unstemmed | Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder |
title_short | Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder |
title_sort | non-invasive hemodynamics monitoring system based on electrocardiography via deep convolutional autoencoder |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469191/ https://www.ncbi.nlm.nih.gov/pubmed/34577471 http://dx.doi.org/10.3390/s21186264 |
work_keys_str_mv | AT sadrawimuammar noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT linyintsong noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT linchienhung noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT mathunjwabhekumuzi noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT hsinhotsung noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT fanshouzen noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT abbodmaysamf noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder AT shiehjiannshing noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder |