Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder

This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet data...

Descripción completa

Detalles Bibliográficos
Autores principales: Sadrawi, Muammar, Lin, Yin-Tsong, Lin, Chien-Hung, Mathunjwa, Bhekumuzi, Hsin, Ho-Tsung, Fan, Shou-Zen, Abbod, Maysam F., Shieh, Jiann-Shing
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469191/
https://www.ncbi.nlm.nih.gov/pubmed/34577471
http://dx.doi.org/10.3390/s21186264
_version_ 1784573867363139584
author Sadrawi, Muammar
Lin, Yin-Tsong
Lin, Chien-Hung
Mathunjwa, Bhekumuzi
Hsin, Ho-Tsung
Fan, Shou-Zen
Abbod, Maysam F.
Shieh, Jiann-Shing
author_facet Sadrawi, Muammar
Lin, Yin-Tsong
Lin, Chien-Hung
Mathunjwa, Bhekumuzi
Hsin, Ho-Tsung
Fan, Shou-Zen
Abbod, Maysam F.
Shieh, Jiann-Shing
author_sort Sadrawi, Muammar
collection PubMed
description This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet database are used for cardiovascular and cerebral hemodynamics, respectively. For cardiovascular hemodynamics, the ECG is used for generating the arterial blood pressure (ABP), central venous pressure (CVP), and pulmonary arterial pressure (PAP). Meanwhile, for cerebral hemodynamics, the ECG is utilized for the intracranial pressure (ICP) generator. A deep convolutional autoencoder system is applied for this study. The cross-validation method with Pearson’s linear correlation (R), root mean squared error (RMSE), and mean absolute error (MAE) are measured for the evaluations. Initially, the ECG is used to generate the cardiovascular waveform. For the ABP system—the systolic blood pressure (SBP) and diastolic blood pressures (DBP)—the R evaluations are 0.894 ± 0.004 and 0.881 ± 0.005, respectively. The MAE evaluations for SBP and DBP are, respectively, 6.645 ± 0.353 mmHg and 3.210 ± 0.104 mmHg. Furthermore, for the PAP system—the systolic and diastolic pressures—the R evaluations are 0.864 ± 0.003 mmHg and 0.817 ± 0.006 mmHg, respectively. The MAE evaluations for systolic and diastolic pressures are, respectively, 3.847 ± 0.136 mmHg and 2.964 ± 0.181 mmHg. Meanwhile, the mean CVP evaluations are 0.916 ± 0.001, 2.220 ± 0.039 mmHg, and 1.329 ± 0.036 mmHg, respectively, for R, RMSE, and MAE. For the mean ICP evaluation in cerebral hemodynamics, the R and MAE evaluations are 0.914 ± 0.003 and 2.404 ± 0.043 mmHg, respectively. This study, as a proof of concept, concludes that the non-invasive cardiovascular and cerebral hemodynamics systems can be potentially investigated by only using the ECG signal.
format Online
Article
Text
id pubmed-8469191
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84691912021-09-27 Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder Sadrawi, Muammar Lin, Yin-Tsong Lin, Chien-Hung Mathunjwa, Bhekumuzi Hsin, Ho-Tsung Fan, Shou-Zen Abbod, Maysam F. Shieh, Jiann-Shing Sensors (Basel) Article This study evaluates cardiovascular and cerebral hemodynamics systems by only using non-invasive electrocardiography (ECG) signals. The Massachusetts General Hospital/Marquette Foundation (MGH/MF) and Cerebral Hemodynamic Autoregulatory Information System Database (CHARIS DB) from the PhysioNet database are used for cardiovascular and cerebral hemodynamics, respectively. For cardiovascular hemodynamics, the ECG is used for generating the arterial blood pressure (ABP), central venous pressure (CVP), and pulmonary arterial pressure (PAP). Meanwhile, for cerebral hemodynamics, the ECG is utilized for the intracranial pressure (ICP) generator. A deep convolutional autoencoder system is applied for this study. The cross-validation method with Pearson’s linear correlation (R), root mean squared error (RMSE), and mean absolute error (MAE) are measured for the evaluations. Initially, the ECG is used to generate the cardiovascular waveform. For the ABP system—the systolic blood pressure (SBP) and diastolic blood pressures (DBP)—the R evaluations are 0.894 ± 0.004 and 0.881 ± 0.005, respectively. The MAE evaluations for SBP and DBP are, respectively, 6.645 ± 0.353 mmHg and 3.210 ± 0.104 mmHg. Furthermore, for the PAP system—the systolic and diastolic pressures—the R evaluations are 0.864 ± 0.003 mmHg and 0.817 ± 0.006 mmHg, respectively. The MAE evaluations for systolic and diastolic pressures are, respectively, 3.847 ± 0.136 mmHg and 2.964 ± 0.181 mmHg. Meanwhile, the mean CVP evaluations are 0.916 ± 0.001, 2.220 ± 0.039 mmHg, and 1.329 ± 0.036 mmHg, respectively, for R, RMSE, and MAE. For the mean ICP evaluation in cerebral hemodynamics, the R and MAE evaluations are 0.914 ± 0.003 and 2.404 ± 0.043 mmHg, respectively. This study, as a proof of concept, concludes that the non-invasive cardiovascular and cerebral hemodynamics systems can be potentially investigated by only using the ECG signal. MDPI 2021-09-18 /pmc/articles/PMC8469191/ /pubmed/34577471 http://dx.doi.org/10.3390/s21186264 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Sadrawi, Muammar
Lin, Yin-Tsong
Lin, Chien-Hung
Mathunjwa, Bhekumuzi
Hsin, Ho-Tsung
Fan, Shou-Zen
Abbod, Maysam F.
Shieh, Jiann-Shing
Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
title Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
title_full Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
title_fullStr Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
title_full_unstemmed Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
title_short Non-Invasive Hemodynamics Monitoring System Based on Electrocardiography via Deep Convolutional Autoencoder
title_sort non-invasive hemodynamics monitoring system based on electrocardiography via deep convolutional autoencoder
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469191/
https://www.ncbi.nlm.nih.gov/pubmed/34577471
http://dx.doi.org/10.3390/s21186264
work_keys_str_mv AT sadrawimuammar noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT linyintsong noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT linchienhung noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT mathunjwabhekumuzi noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT hsinhotsung noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT fanshouzen noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT abbodmaysamf noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder
AT shiehjiannshing noninvasivehemodynamicsmonitoringsystembasedonelectrocardiographyviadeepconvolutionalautoencoder