Cargando…

Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System

We investigated the magnetization dynamics through the magnetoimpedance effect in an integrated YIG/Pt-stripline system in the frequency range of 0.5 up to 2.0 GHz. Specifically, we explore the dependence of the dynamic magnetic behavior on the field orientation by analyzing beyond the traditional l...

Descripción completa

Detalles Bibliográficos
Autores principales: Souza, Arthur L. R., Gamino, Matheus, Ferreira, Armando, de Oliveira, Alexandre B., Vaz, Filipe, Bohn, Felipe, Correa, Marcio A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469266/
https://www.ncbi.nlm.nih.gov/pubmed/34577350
http://dx.doi.org/10.3390/s21186145
_version_ 1784573886837293056
author Souza, Arthur L. R.
Gamino, Matheus
Ferreira, Armando
de Oliveira, Alexandre B.
Vaz, Filipe
Bohn, Felipe
Correa, Marcio A.
author_facet Souza, Arthur L. R.
Gamino, Matheus
Ferreira, Armando
de Oliveira, Alexandre B.
Vaz, Filipe
Bohn, Felipe
Correa, Marcio A.
author_sort Souza, Arthur L. R.
collection PubMed
description We investigated the magnetization dynamics through the magnetoimpedance effect in an integrated YIG/Pt-stripline system in the frequency range of 0.5 up to 2.0 GHz. Specifically, we explore the dependence of the dynamic magnetic behavior on the field orientation by analyzing beyond the traditional longitudinal magnetoimpedance effect of the transverse and perpendicular setups. We disclose here the strong dependence of the effective damping parameter on the field orientation, as well as verification of the very-low damping parameter values for the longitudinal and transverse configurations. We find considerable sensitivity results, bringing to light the facilities to integrate ferrimagnetic insulators in current and future technological applications.
format Online
Article
Text
id pubmed-8469266
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84692662021-09-27 Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System Souza, Arthur L. R. Gamino, Matheus Ferreira, Armando de Oliveira, Alexandre B. Vaz, Filipe Bohn, Felipe Correa, Marcio A. Sensors (Basel) Article We investigated the magnetization dynamics through the magnetoimpedance effect in an integrated YIG/Pt-stripline system in the frequency range of 0.5 up to 2.0 GHz. Specifically, we explore the dependence of the dynamic magnetic behavior on the field orientation by analyzing beyond the traditional longitudinal magnetoimpedance effect of the transverse and perpendicular setups. We disclose here the strong dependence of the effective damping parameter on the field orientation, as well as verification of the very-low damping parameter values for the longitudinal and transverse configurations. We find considerable sensitivity results, bringing to light the facilities to integrate ferrimagnetic insulators in current and future technological applications. MDPI 2021-09-13 /pmc/articles/PMC8469266/ /pubmed/34577350 http://dx.doi.org/10.3390/s21186145 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Souza, Arthur L. R.
Gamino, Matheus
Ferreira, Armando
de Oliveira, Alexandre B.
Vaz, Filipe
Bohn, Felipe
Correa, Marcio A.
Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System
title Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System
title_full Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System
title_fullStr Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System
title_full_unstemmed Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System
title_short Directional Field-Dependence of Magnetoimpedance Effect on Integrated YIG/Pt-Stripline System
title_sort directional field-dependence of magnetoimpedance effect on integrated yig/pt-stripline system
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8469266/
https://www.ncbi.nlm.nih.gov/pubmed/34577350
http://dx.doi.org/10.3390/s21186145
work_keys_str_mv AT souzaarthurlr directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem
AT gaminomatheus directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem
AT ferreiraarmando directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem
AT deoliveiraalexandreb directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem
AT vazfilipe directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem
AT bohnfelipe directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem
AT correamarcioa directionalfielddependenceofmagnetoimpedanceeffectonintegratedyigptstriplinesystem