DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility
In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8470059/ https://www.ncbi.nlm.nih.gov/pubmed/34564507 http://dx.doi.org/10.3390/membranes11090690 |
_version_ | 1784574101378039808 |
---|---|
author | Yuriev, Yuri Goreninskii, Semen Runts, Artem Prosetskaya, Elisaveta Plotnikov, Evgenii Shishkova, Darya Kudryavtseva, Yulia Bolbasov, Evgeny |
author_facet | Yuriev, Yuri Goreninskii, Semen Runts, Artem Prosetskaya, Elisaveta Plotnikov, Evgenii Shishkova, Darya Kudryavtseva, Yulia Bolbasov, Evgeny |
author_sort | Yuriev, Yuri |
collection | PubMed |
description | In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties and cytotoxicity of the membranes modified under various conditions were studied. It was found that DLC coatings do not affect membrane microstructure, preserving its crystal structure as well as its high strength and elongation. It was revealed that an increase in the capacitor storage voltage results in the rise in sp(2)- and sp-hybridized carbon concentration, which makes it possible to control the chemical structure and surface energy of the modified surface. The experiments with 3T3L1 fibroblasts showed no toxic effects of the materials extracts. |
format | Online Article Text |
id | pubmed-8470059 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84700592021-09-27 DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility Yuriev, Yuri Goreninskii, Semen Runts, Artem Prosetskaya, Elisaveta Plotnikov, Evgenii Shishkova, Darya Kudryavtseva, Yulia Bolbasov, Evgeny Membranes (Basel) Article In this paper, the results on the fabrication of ferroelectric membranes as vascular patches with modified surfaces are presented. For the modification of a membrane surface contacting blood, DLC coating was deposited using the pulsed vacuum arc deposition technique. The physico-chemical properties and cytotoxicity of the membranes modified under various conditions were studied. It was found that DLC coatings do not affect membrane microstructure, preserving its crystal structure as well as its high strength and elongation. It was revealed that an increase in the capacitor storage voltage results in the rise in sp(2)- and sp-hybridized carbon concentration, which makes it possible to control the chemical structure and surface energy of the modified surface. The experiments with 3T3L1 fibroblasts showed no toxic effects of the materials extracts. MDPI 2021-09-07 /pmc/articles/PMC8470059/ /pubmed/34564507 http://dx.doi.org/10.3390/membranes11090690 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Yuriev, Yuri Goreninskii, Semen Runts, Artem Prosetskaya, Elisaveta Plotnikov, Evgenii Shishkova, Darya Kudryavtseva, Yulia Bolbasov, Evgeny DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility |
title | DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility |
title_full | DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility |
title_fullStr | DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility |
title_full_unstemmed | DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility |
title_short | DLC-Coated Ferroelectric Membranes as Vascular Patches: Physico-Chemical Properties and Biocompatibility |
title_sort | dlc-coated ferroelectric membranes as vascular patches: physico-chemical properties and biocompatibility |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8470059/ https://www.ncbi.nlm.nih.gov/pubmed/34564507 http://dx.doi.org/10.3390/membranes11090690 |
work_keys_str_mv | AT yurievyuri dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT goreninskiisemen dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT runtsartem dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT prosetskayaelisaveta dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT plotnikovevgenii dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT shishkovadarya dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT kudryavtsevayulia dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility AT bolbasovevgeny dlccoatedferroelectricmembranesasvascularpatchesphysicochemicalpropertiesandbiocompatibility |