Cargando…

Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws

Purpose: This study aims to elucidate the radiological outcome after Cortical bone trajectory (CBT) screw fixation and whether dual-threaded (DT) screws should be used in the fusion surgery. Methods: 159 patients with degenerative lumbar disorder who had undergone midline lumbar inter-body fusion su...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Chao-Hsuan, Tu, Chih-Hsiu, Chen, Der-Cherng, Huang, Hsiang-Ming, Chuang, Hao-Yu, Cho, Der-Yang, Bau, Da-Tian, Lee, Han-Chung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8470344/
https://www.ncbi.nlm.nih.gov/pubmed/34564091
http://dx.doi.org/10.3390/medicines8090050
_version_ 1784574175099224064
author Chen, Chao-Hsuan
Tu, Chih-Hsiu
Chen, Der-Cherng
Huang, Hsiang-Ming
Chuang, Hao-Yu
Cho, Der-Yang
Bau, Da-Tian
Lee, Han-Chung
author_facet Chen, Chao-Hsuan
Tu, Chih-Hsiu
Chen, Der-Cherng
Huang, Hsiang-Ming
Chuang, Hao-Yu
Cho, Der-Yang
Bau, Da-Tian
Lee, Han-Chung
author_sort Chen, Chao-Hsuan
collection PubMed
description Purpose: This study aims to elucidate the radiological outcome after Cortical bone trajectory (CBT) screw fixation and whether dual-threaded (DT) screws should be used in the fusion surgery. Methods: 159 patients with degenerative lumbar disorder who had undergone midline lumbar inter-body fusion surgery by CBT screw-fixation technique (2014 to 2018). Patient subgroups were based on single-threaded (ST) or DT screw, fixation length, as well as whether fixation involved to sacrum level (S1). Serial dynamic plain films were reviewed and an appearance of a halo phenomenon between screw–bone interfaces was identified as a case of screw loosening. Results: 29 patients (39.7%) in ST group and 10 patients (11.6%) in DT group demonstrated a halo phenomenon (p < 0.0001 ****). After subgrouping with fixation length, the incidence rates of a halo phenomenon in each group were 11.1%:3% (ST-1L vs. DT-1L), 37%:13.8% (ST-2L vs. DT-2L), and 84.2%:23.5% (ST-3L vs. DT-3L). Among the 85 patients with a fixation involved in S1, 26 patients (52%) with single-threaded screw (STS group) and 8 patients (22.8%) with dual-threaded screw (DTS group) demonstrated a halo appearance (p = 0.0078 **). After subgrouping the fixation level, the incidence of a halo appearance in each group was 25%:0% (STS-1L vs. DTS-1L), 40.9%:26.3% (STS-2L vs. DTS-2L), and 87.5%: 30% (STS-3L vs. DTS-3L). Conclusion: Both fixation length and whether fixation involved to S1 contribute to the incidence of screw loosening, the data supports clinical evidence that DT screws had greater fixation strength with an increased fixative stability and lower incidence of screw loosening in CBT screw fixation compared with ST screws. Level of evidence: 2.
format Online
Article
Text
id pubmed-8470344
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84703442021-09-27 Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws Chen, Chao-Hsuan Tu, Chih-Hsiu Chen, Der-Cherng Huang, Hsiang-Ming Chuang, Hao-Yu Cho, Der-Yang Bau, Da-Tian Lee, Han-Chung Medicines (Basel) Article Purpose: This study aims to elucidate the radiological outcome after Cortical bone trajectory (CBT) screw fixation and whether dual-threaded (DT) screws should be used in the fusion surgery. Methods: 159 patients with degenerative lumbar disorder who had undergone midline lumbar inter-body fusion surgery by CBT screw-fixation technique (2014 to 2018). Patient subgroups were based on single-threaded (ST) or DT screw, fixation length, as well as whether fixation involved to sacrum level (S1). Serial dynamic plain films were reviewed and an appearance of a halo phenomenon between screw–bone interfaces was identified as a case of screw loosening. Results: 29 patients (39.7%) in ST group and 10 patients (11.6%) in DT group demonstrated a halo phenomenon (p < 0.0001 ****). After subgrouping with fixation length, the incidence rates of a halo phenomenon in each group were 11.1%:3% (ST-1L vs. DT-1L), 37%:13.8% (ST-2L vs. DT-2L), and 84.2%:23.5% (ST-3L vs. DT-3L). Among the 85 patients with a fixation involved in S1, 26 patients (52%) with single-threaded screw (STS group) and 8 patients (22.8%) with dual-threaded screw (DTS group) demonstrated a halo appearance (p = 0.0078 **). After subgrouping the fixation level, the incidence of a halo appearance in each group was 25%:0% (STS-1L vs. DTS-1L), 40.9%:26.3% (STS-2L vs. DTS-2L), and 87.5%: 30% (STS-3L vs. DTS-3L). Conclusion: Both fixation length and whether fixation involved to S1 contribute to the incidence of screw loosening, the data supports clinical evidence that DT screws had greater fixation strength with an increased fixative stability and lower incidence of screw loosening in CBT screw fixation compared with ST screws. Level of evidence: 2. MDPI 2021-09-02 /pmc/articles/PMC8470344/ /pubmed/34564091 http://dx.doi.org/10.3390/medicines8090050 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Chen, Chao-Hsuan
Tu, Chih-Hsiu
Chen, Der-Cherng
Huang, Hsiang-Ming
Chuang, Hao-Yu
Cho, Der-Yang
Bau, Da-Tian
Lee, Han-Chung
Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws
title Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws
title_full Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws
title_fullStr Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws
title_full_unstemmed Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws
title_short Incidence of Screw Loosening in Cortical Bone Trajectory Fixation Technique between Single- and Dual-Threaded Screws
title_sort incidence of screw loosening in cortical bone trajectory fixation technique between single- and dual-threaded screws
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8470344/
https://www.ncbi.nlm.nih.gov/pubmed/34564091
http://dx.doi.org/10.3390/medicines8090050
work_keys_str_mv AT chenchaohsuan incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT tuchihhsiu incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT chendercherng incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT huanghsiangming incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT chuanghaoyu incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT choderyang incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT baudatian incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews
AT leehanchung incidenceofscrewlooseningincorticalbonetrajectoryfixationtechniquebetweensingleanddualthreadedscrews