Cargando…
Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls
Background: Automated molecular panels are attractive tools for improving early meningitis diagnosis. This study assessed the Eazyplex(®) CSF direct M panel (EP), a multiplex real-time Loop-Mediated Isothermal Amplification assay. Methods: From December 2016 to December 2019, cerebrospinal fluid (CS...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8471247/ https://www.ncbi.nlm.nih.gov/pubmed/34576754 http://dx.doi.org/10.3390/microorganisms9091859 |
_version_ | 1784574414910652416 |
---|---|
author | Leroy, Anne-Gaëlle Persyn, Elise Gibaud, Sophie-Anne Crémet, Lise Le Turnier, Paul Benhamida, Myriam Launay, Elise Guillouzouic, Aurélie Bémer, Pascale Corvec, Stéphane |
author_facet | Leroy, Anne-Gaëlle Persyn, Elise Gibaud, Sophie-Anne Crémet, Lise Le Turnier, Paul Benhamida, Myriam Launay, Elise Guillouzouic, Aurélie Bémer, Pascale Corvec, Stéphane |
author_sort | Leroy, Anne-Gaëlle |
collection | PubMed |
description | Background: Automated molecular panels are attractive tools for improving early meningitis diagnosis. This study assessed the Eazyplex(®) CSF direct M panel (EP), a multiplex real-time Loop-Mediated Isothermal Amplification assay. Methods: From December 2016 to December 2019, cerebrospinal fluid (CSF) samples were routinely tested with the EP V1.0. CSF parameters and microbiological and clinical data were retrospectively collected. Results: Out of 230 CSF samples, the EP yielded positive, negative, and invalid results for 32 (13.9%) (16 N. meningitidis, nine S. pneumoniae, two S. agalactiae, two E. coli, two H. influenzae, one L. monocytogenes), 182 (79.1%), and 16 (7%) samples, respectively. Among the positive samples, 14 (44%) remained negative in culture (antibiotic therapy before lumbar puncture (n = 11), meningococcal meningitis (n = 3)). High CSF protein concentrations and cellularity were associated with LAMP inhibition, counteracted by centrifugation. The automated software yielded 13 false positive and five false negative results. Amplification curve analysis was necessary and enabled the attainment of positive (PPA) and negative percentage agreement and positive and negative predictive values of 91.4%, 100%, 100%, and 98.3%. Three false negative results remained (two E. coli and one N. meningitidis). E. coli presented the poorest PPA (50%). Conclusion: This work confirms the strong performance of the EP, of particular interest in cases of antibiotic therapy before lumbar puncture. |
format | Online Article Text |
id | pubmed-8471247 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-84712472021-09-27 Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls Leroy, Anne-Gaëlle Persyn, Elise Gibaud, Sophie-Anne Crémet, Lise Le Turnier, Paul Benhamida, Myriam Launay, Elise Guillouzouic, Aurélie Bémer, Pascale Corvec, Stéphane Microorganisms Article Background: Automated molecular panels are attractive tools for improving early meningitis diagnosis. This study assessed the Eazyplex(®) CSF direct M panel (EP), a multiplex real-time Loop-Mediated Isothermal Amplification assay. Methods: From December 2016 to December 2019, cerebrospinal fluid (CSF) samples were routinely tested with the EP V1.0. CSF parameters and microbiological and clinical data were retrospectively collected. Results: Out of 230 CSF samples, the EP yielded positive, negative, and invalid results for 32 (13.9%) (16 N. meningitidis, nine S. pneumoniae, two S. agalactiae, two E. coli, two H. influenzae, one L. monocytogenes), 182 (79.1%), and 16 (7%) samples, respectively. Among the positive samples, 14 (44%) remained negative in culture (antibiotic therapy before lumbar puncture (n = 11), meningococcal meningitis (n = 3)). High CSF protein concentrations and cellularity were associated with LAMP inhibition, counteracted by centrifugation. The automated software yielded 13 false positive and five false negative results. Amplification curve analysis was necessary and enabled the attainment of positive (PPA) and negative percentage agreement and positive and negative predictive values of 91.4%, 100%, 100%, and 98.3%. Three false negative results remained (two E. coli and one N. meningitidis). E. coli presented the poorest PPA (50%). Conclusion: This work confirms the strong performance of the EP, of particular interest in cases of antibiotic therapy before lumbar puncture. MDPI 2021-09-01 /pmc/articles/PMC8471247/ /pubmed/34576754 http://dx.doi.org/10.3390/microorganisms9091859 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Leroy, Anne-Gaëlle Persyn, Elise Gibaud, Sophie-Anne Crémet, Lise Le Turnier, Paul Benhamida, Myriam Launay, Elise Guillouzouic, Aurélie Bémer, Pascale Corvec, Stéphane Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls |
title | Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls |
title_full | Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls |
title_fullStr | Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls |
title_full_unstemmed | Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls |
title_short | Assessment of a Multiplex LAMP Assay (Eazyplex(®) CSF Direct M) for Rapid Molecular Diagnosis of Bacterial Meningitis: Accuracy and Pitfalls |
title_sort | assessment of a multiplex lamp assay (eazyplex(®) csf direct m) for rapid molecular diagnosis of bacterial meningitis: accuracy and pitfalls |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8471247/ https://www.ncbi.nlm.nih.gov/pubmed/34576754 http://dx.doi.org/10.3390/microorganisms9091859 |
work_keys_str_mv | AT leroyannegaelle assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT persynelise assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT gibaudsophieanne assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT cremetlise assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT leturnierpaul assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT benhamidamyriam assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT launayelise assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT guillouzouicaurelie assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT bemerpascale assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT corvecstephane assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls AT assessmentofamultiplexlampassayeazyplexcsfdirectmforrapidmoleculardiagnosisofbacterialmeningitisaccuracyandpitfalls |