Cargando…

Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion

Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) displays an effective method for treating portal hypertension. Main indications include refractory ascites and secondary prevention of esophageal bleeding. Color Doppler ultrasound (CDUS) plays a leadi...

Descripción completa

Detalles Bibliográficos
Autores principales: Marschner, Constantin A., Geyer, Thomas, Froelich, Matthias F., Rübenthaler, Johannes, Schwarze, Vincent, Clevert, Dirk-André
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8472159/
https://www.ncbi.nlm.nih.gov/pubmed/34573935
http://dx.doi.org/10.3390/diagnostics11091593
_version_ 1784574657223983104
author Marschner, Constantin A.
Geyer, Thomas
Froelich, Matthias F.
Rübenthaler, Johannes
Schwarze, Vincent
Clevert, Dirk-André
author_facet Marschner, Constantin A.
Geyer, Thomas
Froelich, Matthias F.
Rübenthaler, Johannes
Schwarze, Vincent
Clevert, Dirk-André
author_sort Marschner, Constantin A.
collection PubMed
description Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) displays an effective method for treating portal hypertension. Main indications include refractory ascites and secondary prevention of esophageal bleeding. Color Doppler ultrasound (CDUS) plays a leading role in the follow-up management, whereas contrast-enhanced ultrasound (CEUS) is not routinely considered. We compared the efficacy of CEUS to CDUS and highlighted differences compared to findings of corresponding computed tomography (CT) and magnetic resonance imaging (MRI). (2) Methods: On a retrospective basis, 106 patients with CEUS examination after TIPS were included. The enrollment period was 12 years (between 2008 and 2020) and the age group ranged from 23.3 to 82.1 years. In addition, 92 CDUS, 43 CT and 58 MRI scans were evaluated for intermodal comparison. (3) Results: Intermodal analysis and comparison revealed a high level of concordance between CDUS, CT and MRI in the vast majority of cases. In comparison to CDUS, the correlation of the relevant findings was 92.5%, 95.3% for CT and 87.9% for MRI. In some cases, however, additional information was provided by CEUS (4) Conclusions: CEUS depicts a safe and effective imaging modality for follow-up after TIPS. In addition to CDUS, CEUS enables specific assessment of stent pathologies and stent dysfunction due to its capacity to dynamically visualize single microbubbles at high spatial and temporal resolution. Due to the low number of adverse events regarding the application of contrast agents, CEUS can be administered to a very broad patient population, thus avoiding additional radiation exposure compared to CT angiography in cases with divergent findings during follow-up.
format Online
Article
Text
id pubmed-8472159
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84721592021-09-28 Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion Marschner, Constantin A. Geyer, Thomas Froelich, Matthias F. Rübenthaler, Johannes Schwarze, Vincent Clevert, Dirk-André Diagnostics (Basel) Article Background: In patients with liver cirrhosis, transjugular intrahepatic portosystemic shunt (TIPS) displays an effective method for treating portal hypertension. Main indications include refractory ascites and secondary prevention of esophageal bleeding. Color Doppler ultrasound (CDUS) plays a leading role in the follow-up management, whereas contrast-enhanced ultrasound (CEUS) is not routinely considered. We compared the efficacy of CEUS to CDUS and highlighted differences compared to findings of corresponding computed tomography (CT) and magnetic resonance imaging (MRI). (2) Methods: On a retrospective basis, 106 patients with CEUS examination after TIPS were included. The enrollment period was 12 years (between 2008 and 2020) and the age group ranged from 23.3 to 82.1 years. In addition, 92 CDUS, 43 CT and 58 MRI scans were evaluated for intermodal comparison. (3) Results: Intermodal analysis and comparison revealed a high level of concordance between CDUS, CT and MRI in the vast majority of cases. In comparison to CDUS, the correlation of the relevant findings was 92.5%, 95.3% for CT and 87.9% for MRI. In some cases, however, additional information was provided by CEUS (4) Conclusions: CEUS depicts a safe and effective imaging modality for follow-up after TIPS. In addition to CDUS, CEUS enables specific assessment of stent pathologies and stent dysfunction due to its capacity to dynamically visualize single microbubbles at high spatial and temporal resolution. Due to the low number of adverse events regarding the application of contrast agents, CEUS can be administered to a very broad patient population, thus avoiding additional radiation exposure compared to CT angiography in cases with divergent findings during follow-up. MDPI 2021-09-01 /pmc/articles/PMC8472159/ /pubmed/34573935 http://dx.doi.org/10.3390/diagnostics11091593 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Marschner, Constantin A.
Geyer, Thomas
Froelich, Matthias F.
Rübenthaler, Johannes
Schwarze, Vincent
Clevert, Dirk-André
Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion
title Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion
title_full Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion
title_fullStr Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion
title_full_unstemmed Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion
title_short Diagnostic Value of Contrast-Enhanced Ultrasound for Evaluation of Transjugular Intrahepatic Portosystemic Shunt Perfusion
title_sort diagnostic value of contrast-enhanced ultrasound for evaluation of transjugular intrahepatic portosystemic shunt perfusion
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8472159/
https://www.ncbi.nlm.nih.gov/pubmed/34573935
http://dx.doi.org/10.3390/diagnostics11091593
work_keys_str_mv AT marschnerconstantina diagnosticvalueofcontrastenhancedultrasoundforevaluationoftransjugularintrahepaticportosystemicshuntperfusion
AT geyerthomas diagnosticvalueofcontrastenhancedultrasoundforevaluationoftransjugularintrahepaticportosystemicshuntperfusion
AT froelichmatthiasf diagnosticvalueofcontrastenhancedultrasoundforevaluationoftransjugularintrahepaticportosystemicshuntperfusion
AT rubenthalerjohannes diagnosticvalueofcontrastenhancedultrasoundforevaluationoftransjugularintrahepaticportosystemicshuntperfusion
AT schwarzevincent diagnosticvalueofcontrastenhancedultrasoundforevaluationoftransjugularintrahepaticportosystemicshuntperfusion
AT clevertdirkandre diagnosticvalueofcontrastenhancedultrasoundforevaluationoftransjugularintrahepaticportosystemicshuntperfusion