Cargando…

Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors

Air pollution is a social problem, because the harmful suspended materials can cause diseases and deaths to humans. Specifically, particulate matters (PM), a form of air pollution, can contribute to cardiovascular morbidity and lung diseases. Nowadays, humans are exposed to PM pollution everywhere b...

Descripción completa

Detalles Bibliográficos
Autores principales: Cho, Hyuntae, Baek, Yunju
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8472837/
https://www.ncbi.nlm.nih.gov/pubmed/34577369
http://dx.doi.org/10.3390/s21186162
_version_ 1784574837163819008
author Cho, Hyuntae
Baek, Yunju
author_facet Cho, Hyuntae
Baek, Yunju
author_sort Cho, Hyuntae
collection PubMed
description Air pollution is a social problem, because the harmful suspended materials can cause diseases and deaths to humans. Specifically, particulate matters (PM), a form of air pollution, can contribute to cardiovascular morbidity and lung diseases. Nowadays, humans are exposed to PM pollution everywhere because it occurs in both indoor and outdoor environments. To purify or ventilate polluted air, one need to accurately monitor the ambient air quality. Therefore, this study proposed a practical particulate matter sensing and accurate calibration system using low-cost commercial sensors. The proposed system basically uses noisy and inaccurate PM sensors to measure the ambient air pollution. This paper mainly deals with three types of error caused in the light scattering method: short-term noise, part-to-part variation, and temperature and humidity interferences. We propose a simple short-term noise reduction method to correct measurement errors, an auto-fitting calibration for part-to-part repeatability to pinpoint the baseline of the signal that affects the performance of the system, and a temperature and humidity compensation method. This paper also contains the experiment setup and performance evaluation to prove the superiority of the proposed methods. Based on the evaluation of the performance of the proposed system, part-to-part repeatability was less than 2 μg/m(3) and the standard deviation was approximately 1.1 μg/m(3) in the air. When the proposed approaches are used for other optical sensors, it can result in better performance.
format Online
Article
Text
id pubmed-8472837
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84728372021-09-28 Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors Cho, Hyuntae Baek, Yunju Sensors (Basel) Article Air pollution is a social problem, because the harmful suspended materials can cause diseases and deaths to humans. Specifically, particulate matters (PM), a form of air pollution, can contribute to cardiovascular morbidity and lung diseases. Nowadays, humans are exposed to PM pollution everywhere because it occurs in both indoor and outdoor environments. To purify or ventilate polluted air, one need to accurately monitor the ambient air quality. Therefore, this study proposed a practical particulate matter sensing and accurate calibration system using low-cost commercial sensors. The proposed system basically uses noisy and inaccurate PM sensors to measure the ambient air pollution. This paper mainly deals with three types of error caused in the light scattering method: short-term noise, part-to-part variation, and temperature and humidity interferences. We propose a simple short-term noise reduction method to correct measurement errors, an auto-fitting calibration for part-to-part repeatability to pinpoint the baseline of the signal that affects the performance of the system, and a temperature and humidity compensation method. This paper also contains the experiment setup and performance evaluation to prove the superiority of the proposed methods. Based on the evaluation of the performance of the proposed system, part-to-part repeatability was less than 2 μg/m(3) and the standard deviation was approximately 1.1 μg/m(3) in the air. When the proposed approaches are used for other optical sensors, it can result in better performance. MDPI 2021-09-14 /pmc/articles/PMC8472837/ /pubmed/34577369 http://dx.doi.org/10.3390/s21186162 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Cho, Hyuntae
Baek, Yunju
Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
title Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
title_full Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
title_fullStr Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
title_full_unstemmed Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
title_short Practical Particulate Matter Sensing and Accurate Calibration System Using Low-Cost Commercial Sensors
title_sort practical particulate matter sensing and accurate calibration system using low-cost commercial sensors
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8472837/
https://www.ncbi.nlm.nih.gov/pubmed/34577369
http://dx.doi.org/10.3390/s21186162
work_keys_str_mv AT chohyuntae practicalparticulatemattersensingandaccuratecalibrationsystemusinglowcostcommercialsensors
AT baekyunju practicalparticulatemattersensingandaccuratecalibrationsystemusinglowcostcommercialsensors