Cargando…

Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis

Standardization and validation of alternative cell lysis methods used for quantifying total cyanotoxins is needed to improve laboratory response time goals for total cyanotoxin analysis. In this study, five cell lysis methods (i.e., probe sonication, microwave, freeze-thaw, chemical lysis with Abrax...

Descripción completa

Detalles Bibliográficos
Autores principales: Greenstein, Katherine E., Zamyadi, Arash, Wert, Eric C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473049/
https://www.ncbi.nlm.nih.gov/pubmed/34564601
http://dx.doi.org/10.3390/toxins13090596
_version_ 1784574891126685696
author Greenstein, Katherine E.
Zamyadi, Arash
Wert, Eric C.
author_facet Greenstein, Katherine E.
Zamyadi, Arash
Wert, Eric C.
author_sort Greenstein, Katherine E.
collection PubMed
description Standardization and validation of alternative cell lysis methods used for quantifying total cyanotoxins is needed to improve laboratory response time goals for total cyanotoxin analysis. In this study, five cell lysis methods (i.e., probe sonication, microwave, freeze-thaw, chemical lysis with Abraxis QuikLyse(TM), and chemical lysis with copper sulfate) were assessed using laboratory-cultured Microcystis aeruginosa (M. aeruginosa) cells. Methods were evaluated for destruction of cells (as determined by optical density of the sample) and recovery of total microcystin-LR (MC-LR) using three M. aeruginosa cell densities (i.e., 1 × 10(5) cells/mL (low-density), 1 × 10(6) cells/mL (medium-density), and 1 × 10(7) cells/mL (high-density)). Of the physical lysis methods, both freeze-thaw (1 to 5 cycles) and pulsed probe sonication (2 to 10 min) resulted in >80% destruction of cells and consistent (>80%) release and recovery of intracellular MC-LR. Microwave (3 to 5 min) did not demonstrate the same decrease in optical density (<50%), although it provided effective release and recovery of >80% intracellular MC-LR. Abraxis QuikLyse(TM) was similarly effective for intracellular MC-LR recovery across the different M. aeruginosa cell densities. Copper sulfate (up to 500 mg/L Cu(2+)) did not lyse cells nor release intracellular MC-LR within 20 min. None of the methods appeared to cause degradation of MC-LR. Probe sonication, microwave, and Abraxis QuikLyse(TM) served as rapid lysis methods (within minutes) with varying associated costs, while freeze-thaw provided a viable, low-cost alternative if time permits.
format Online
Article
Text
id pubmed-8473049
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-84730492021-09-28 Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis Greenstein, Katherine E. Zamyadi, Arash Wert, Eric C. Toxins (Basel) Article Standardization and validation of alternative cell lysis methods used for quantifying total cyanotoxins is needed to improve laboratory response time goals for total cyanotoxin analysis. In this study, five cell lysis methods (i.e., probe sonication, microwave, freeze-thaw, chemical lysis with Abraxis QuikLyse(TM), and chemical lysis with copper sulfate) were assessed using laboratory-cultured Microcystis aeruginosa (M. aeruginosa) cells. Methods were evaluated for destruction of cells (as determined by optical density of the sample) and recovery of total microcystin-LR (MC-LR) using three M. aeruginosa cell densities (i.e., 1 × 10(5) cells/mL (low-density), 1 × 10(6) cells/mL (medium-density), and 1 × 10(7) cells/mL (high-density)). Of the physical lysis methods, both freeze-thaw (1 to 5 cycles) and pulsed probe sonication (2 to 10 min) resulted in >80% destruction of cells and consistent (>80%) release and recovery of intracellular MC-LR. Microwave (3 to 5 min) did not demonstrate the same decrease in optical density (<50%), although it provided effective release and recovery of >80% intracellular MC-LR. Abraxis QuikLyse(TM) was similarly effective for intracellular MC-LR recovery across the different M. aeruginosa cell densities. Copper sulfate (up to 500 mg/L Cu(2+)) did not lyse cells nor release intracellular MC-LR within 20 min. None of the methods appeared to cause degradation of MC-LR. Probe sonication, microwave, and Abraxis QuikLyse(TM) served as rapid lysis methods (within minutes) with varying associated costs, while freeze-thaw provided a viable, low-cost alternative if time permits. MDPI 2021-08-26 /pmc/articles/PMC8473049/ /pubmed/34564601 http://dx.doi.org/10.3390/toxins13090596 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Greenstein, Katherine E.
Zamyadi, Arash
Wert, Eric C.
Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis
title Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis
title_full Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis
title_fullStr Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis
title_full_unstemmed Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis
title_short Comparative Assessment of Physical and Chemical Cyanobacteria Cell Lysis Methods for Total Microcystin-LR Analysis
title_sort comparative assessment of physical and chemical cyanobacteria cell lysis methods for total microcystin-lr analysis
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8473049/
https://www.ncbi.nlm.nih.gov/pubmed/34564601
http://dx.doi.org/10.3390/toxins13090596
work_keys_str_mv AT greensteinkatherinee comparativeassessmentofphysicalandchemicalcyanobacteriacelllysismethodsfortotalmicrocystinlranalysis
AT zamyadiarash comparativeassessmentofphysicalandchemicalcyanobacteriacelllysismethodsfortotalmicrocystinlranalysis
AT wertericc comparativeassessmentofphysicalandchemicalcyanobacteriacelllysismethodsfortotalmicrocystinlranalysis